datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley 3880-1,0

Keithley 3880-1,0 free download

Various electronics service manuals

File information:
File name:3880-1,0.pdf
[preview 3880-1,0]
Size:7 kB
Extension:pdf
Mfg:Keithley
Model:3880-1,0 🔎
Original:3880-1,0 🔎
Descr: Keithley 2001M CDROM Digital Multimeters - Data Acquisition - Switch Systems Product Information CD_Content pdfs app_notes 3880-1,0.pdf
Group:Electronics > Other
Uploaded:09-11-2021
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 3880-1,0.pdf

Displaying The Windows of the 2001 Under normal usage of the 2001, a user would use the :SENSE:DATA? to return a reading from the 2001. Using this command only returns the data in the primary window. It does not return the units nor does it return any of the information from the secondary display. If a programmer chooses to return the data from the secondary window, he or she would have to program the 2001 to measure the very specific paramters. For example, if the 2001 is set for DC volts and the next button was pushed, the display may look as follows: +064.8283 mVDC +000.405 mVAC +060.15 Hz In this case, only the value +64.8283E-03 would be returned to the computer. To return the entire display, the command :DISPLAY:WINDOW1:DATA? is sent to the 2001 to return the first window display and :DISPLAY:WINDOW2:DATA? is sent to return the second window display. As shown in the example program below, both windows can be returned: If meter_enabled Then cmd$=":DISPLAY:WINDOW1:DATA?" Call Send(GPIBAddress,cmd$,status%) If status% = 0 Then Call Enter(disp1$, 21, l%, GPIBAddress, status%) If status% = 0 Then cmd$=":DISPLAY:WINDOW2:DATA?" Call Send(GPIBAddress,cmd$,status%) If status% = 0 Then Call Enter(disp2$, 33, l%, GPIBAddress, status%) If status% = 0 Then Print disp1$ Print disp2$ End If End If End If End If End if Please note in each Call Enter commands the values 21 and 33. The top window of the 2001 can display 20 characters and the bottom window can display 32 characters. When the window string is returned to the host computer, all 20 and 32 characters are returned along with an additional line feed (LF) character. Thus, to properly transfer the entire window string, 21 and 33 characters must be returned, otherwise, an error condition will occur. When both window strings have been transferred, the information can be displayed on the CRT or an application program can separately parse the information for the numerical data only for future use. John Tucker 5/1/92

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : LG L1918S

script execution: 0.02 s