datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....
(welcome to eserviceinfo.com at 19 May 07:38 pm GMT)

[news] Check out the Pinout Forum [/news]
Login:
Password:

[registration] [send password]
Bulgarian - schematics repairs service manuals English - schematics repairs service manuals Russian - schematics repairs service manuals           back - schematics, service manuals, datasheets forward - schematics, service manuals, datasheetsSearchBrowseUploadMostWantedLinksForumInfo/Contacts


Now downloading free:sharp 14MR10  [report bad file]  

TV - Conventional CRT, LCD Projectors, TFT, Plasma, Big Screen, HDTV, Home theater - Service manuals, repair tips

File information:
File name:14MR10.rar
[preview 14MR10] new window
Size:1061 kB
Extension:1.03
MD5 Checksum:7df5bed1fb1b221bde65b5e003b860da
Mfg:sharp
Model:14MR10
Original no||Chassis||Ordercode:14MR10
Description:de parte de un amigo de coatzacoalcos veracruz .MEXICO,alguien que tenga y pueda obsequiar un diagrama de tv panasonic CT-F2943XG O alguno parecido emal juansevala@hotmail.com
Group:Electronics > Consumer electronics > TV >
Uploaded:2007-07-19 07:04:03
User:96380
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:6
File nameRead resultText
p13.pdf14MR10 BLOCK DIAGRAM H G F E D C B A 1 2 3 4 5 6 13
p14.pdf14MR10 DESCRIPTION OF SCHEMATIC DIAGRAM NOTES: 1. The unit of resistance "ohm" is omitted. (K=k=1000, M=M) 2. All resistors are 1/10 watt, unless otherwise noted. 3. All capacitors are µ F, unless otherwise noted. (P=pF=µµF) 4. (G) indicates ±2% tolerance may be used. 5. indicates line isolated ground. VOLTAGE MEASUREMENT CONDITIONS: 1. All DC voltages are measured with DVM connected between points indicated and chassis ground, line voltage set at 120V AC and all controls set for normal picture unless otherwise indicated. 2. All voltages measured with 1000µ V B & W or Color signal. WAVEFORM MEASUREMENT CONDITIONS: 1. Photographs taken on a standard gated color bar signal, the tint setting adjusted for proper color. The wave shapes at the red, green and blue cathodes of the picture tube depend on the tint, color level and picture control. 2. indicates waveform check points (See chart, waveforms are measured from point indicated to chassis ground.) е AND SHADED ( ) COMPONENTS = SAFETY
p15.pdf14MR10 SCHEMATIC DIAGRAM: CRT Unit H G F E D C B A 1 2 3 4 5 6 15
p16-17.pdfSCHEMATIC DIAGRAM: MAIN Unit J I H G F E D C B A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 16~17
p21-25.pdf14MR10 Ref. No. Part No. 5 Description Code Ref. No. Part No. 5 Description Code PARTS LIST PARTS REPLACEMENT Replacement parts which have these special safety characteristics identified in this manual; electrical components having such features are identified by е and shaded areas in the Replacement Parts Lists and Schematic Diagrams. The use of a substitute replacement part which dose no have the same safety characteristic as the factory recommended replacement parts shown in this service manual may create shock, fire or other hazards. PWB-A : DUNTKA541WEA0 MAIN UNIT TUNER NOTE: THE PARTS HERE SHOWN ARE SUPPLIED AS AN ASSEMBLY BUT NOT INDEPENDETLY е TU201 VTUENV56D82-1 J VHF Tuner or VTUVTST5UF770 AZ "HOW TO ORDER REPLACEMENT PARTS" To have your order filled promptly and correctly, please furnish the following informations. 1. MODEL NUMBER 3. PART NO. 2. REF. NO. 4. DESCRIPTION INTEGRATED CIRCUITS IC302 е IC501 IC601 IC701 IC801 IC1003 VHiAN7511//-1 VHiAN5522++-1 VHiKA7808AP-1 VH
p5-11.pdf14MR10 INSTALLATION AND SERVICE INSTRUCTIONS Note: (1) When performing any adjustments to resistor controls and transformers use screwdrivers or TV alignment tools. (2) Before performing adjustments, the TV set must be on at least 15 minutes. non-metallic CIRCUIT PROTECTION The receiver is protected by a 4.0A fuse (F701), mounted on PWB-A, wired into one side of the AC line input. HIGH VOLTAGE CHECK High voltage is not adjustable but must be checked to verify that the receiver is operating within safe and efficient design limitations as specified checks should be as follows: 1. Connect an accurate high voltage meter between ground and anode of picture tube. 2. Operate receiver for at least 15 minutes at 120V AC line voltage, with a strong air signal or a properly tuned in test signal. 3. Receive a good local channel. 4. The voltage should be approximately, 23.5kV (at Picture MAX, Bright Center condition). If a correct reading cannot be obtained, check circuitry for malfunctioning co

Download restrictions information:
 LimitDownloaded
Day500
Month5000
Wrong count ?
* daily quota restriction will be cleared in 4h 21m

Download >> To download the file, please, click here ! << Download
eServiceInfo Context Help

Do You know someone, who could find this Service Manual useful? Email this link to a friend.

Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Електроника -  Форум електроника -  InK -  Repairs Forum -  Търси новини -  -  electronic circuits -  IPAddressLabs -  ManualZone
 Service Diagrams -  Electronics Lab -  master-tv -  RadioLocman -  electrik.org -  mondetech -  manualsparadise -  Prikachi
 SnimkiOt.com -  Pinout.net -  Търсачка -  Poblizo.com : travel -  Whois разузнаване -  horo.bg -  Ytpo.net -  Pulsator Electronics

script execution: 0.01 s