datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Panasonic kxta308-616

Panasonic kxta308-616 free download

Phone systems, telephone exchanges, pbx, wireless phone, ip telephony,voip, dect - service manuals and repair information

File information:
File name:inst_ta2.PDF
Size:2352 kB
Extension:pdf
Mfg:Panasonic
Model:kxta308-616 🔎 kxta308616
Original:
Descr:inst-man
Group:Electronics > Consumer electronics > Telephones > Telephone exchange
Uploaded:14-03-2009
User:drhook
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name inst_ta2.PDF

Advanced Hybrid System Installation Manual MODEL KX-TA308 KX-TA616 This manual was printed with soy based ink. Please read this manual before connecting the Advanced Hybrid System. System Highlights System Capacity Basic System Expansion Extensions 8 Outside (CO) lines 3 Maximum extensions 24 Maximum outside (CO) lines 6 16 6 24 6 Special System Points System Expansion This system can expand the outside (CO) lines (KX-TA308 only) and extension capacity by installing an optional card. 2­ 24 Direct Backup Power Supply Car batteries can be connected directly to this system as a backup power supply in the event of a power failure. To supply backup power, optional cables are required. 2­ 23 Hybrid This system can accept Panasonic analog proprietary telephones. Also, single line devices such as single line telephones, facsimiles and data terminals can be connected. Calling from the outside (Direct Inward System Access) External callers can call extensions in the system. If you install an optional card, an outgoing message will greet the caller and give information about how to access an extension. 3­ 17 2 Precautions · Keep the unit away from heating appliances and electrical noise generating devices such as fluorescent lamps, motors and televisions. These noise sources can interfere with the performance of the Advanced Hybrid System. · This unit should be kept free of dust, moisture, high temperature (more than 40 °C {104 °F}) and vibration, and should not be exposed to direct sunlight. · Never attempt to insert wires, pins, etc. into the vents or other holes of this unit. · If there is any trouble, disconnect the unit from the telephone line. Plug the telephone directly into the telephone line. If the telephone operates properly, do not reconnect the unit to the line until the trouble has been repaired. If the telephone does not operate properly, chances are that the trouble is in the telephone system, and not in the unit. · Do not use benzine, thinner, or the like, or any abrasive powder to clean the cabinet. Wipe it with a soft cloth. WARNING THIS UNIT MAY ONLY BE INSTALLED AND SERVED BY QUALIFIED SERVICE PERSONNEL. WHEN A FAILURE OCCURS WHICH RESULTS IN THE INTERNAL PARTS BECOMING ACCESSIBLE, DISCONNECT THE POWER SUPPLY CORD IMMEDIATELY AND RETURN THIS UNIT TO YOUR DEALER. DISCONNECT THE TELECOM CONNECTION BEFORE DISCONNECTING THE POWER CONNECTION PRIOR TO RELOCATING THE EQUIPMENT, AND RECONNECT THE POWER FIRST. THIS UNIT IS EQUIPPED WITH AN EARTHING CONTACT PLUG. FOR SAFETY REASONS THIS PLUG MUST ONLY BE CONNECTED TO AN EARTHING CONTACT SOCKET WHICH HAS BEEN INSTALLED ACCORDING TO REGULATIONS. THE POWER SUPPLY CORD IS USED AS THE MAIN DISCONNECT DEVICE, ENSURE THAT THE SOCKET-OUTLET IS LOCATED/INSTALLED NEAR THE EQUIPMENT AND IS EASILY ACCESSIBLE. TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. 3 Precautions For your future reference SERIAL NO. (found on the bottom of the uni

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment
12-05-2009varacom1cant download

Average rating for this file: 1.00 ( from 1 votes)


Similar Service Manuals :
Panasonic KX-T206SBX - Panasonic KX-T206HBX - Panasonic KX-TD1232E - panasonic kx-tdn 1232 - Panasonic KXT206 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Tektronix Oscilloscopio+TDS2012+MANUAL+SERVICE

script execution: 0.02 s