Text preview for : MANUAL SERVICE MX5203MS 13.pdf part of POLYTRON ( INDONESIA ) MX5203MS It used STV2286H , AN5891K , TDA8174 , STB9NK70Z-1 Complete Service Manual in RAR file type.sent by [email protected]



Back to : MX5203MS Service Manual | Home

Service Manual BML Myanmar
2.

PT.Hartono Istana Teknologi

Press menu button to save data Adjustment. Check again if low bright value has non standard value. Repeate same steps to make correction. Check High Bright once again and make correction if its value isn't conforming, until we got

Low Bright and High Bright value according by standard value. APR Adjustment : Acces to service mode. Set APR to 15 value = 21" RF (ABL)

3.

- Press menu button to save data Adjustment. Normalisation setting (memory setting) : Brightness Contrast Color Sharpness = 55 = 100 = 70 = 100 - Tint - PNR - Pic Improve = 00 = OFF = ON

B. For HBBA-067A
1. G2 and White Balance Adjustment : Presetting Condition for WB Adjustment : Brightness = 70 (for flat Hitachi = 75) Contrast Color PNR Blue back R / G / B Cut off B Gain R DC , G DC Trimpot G2 Pic Improve = 100 = 60 = off = on = 60 (RF) = 50 = 32 = Minimum = ON (menu)

Use White Balance (White Black) pattern Acces to Service Mode. a. For IC Micom HBM-00-01H/F,HBM-00-07H,HBM-01-04 - Measure the third cathode (KB, KG, KR) and look for cathode with highest value. - Set trimpot G2 until voltage on highest cathoda as bellow : - For 20",21",21"RF = 118Vdc ± 1Vdc b. For IC Micom HBM-00-08,HBM-00-12 - Make 1 horizontal line (raster tip) by pressing yellow button on remote control. - Set trimpot G2 until we got 1 horizontal line with enough intensity and notice the domi nance color. - Return to normal position by pressing yellow button. - Adjust trimpot G2 until we got voltage on cathoda dominance as bellow : - Untuk 20",21",21" Real flat = 118Vdc ± 1Vdc - Use Chroma meter for White Balance Adjustment. - Plug in Chroma meter probe on the black side.

12