Text preview for : SONY DSLR-A100 SECTION 6 ADJUSTMENTS AUTO-ADJ VER 1.3 2007.10 (9-852-130-54).pdf part of SONY DSLR-A100 SONY DSLR-A100 DIGITAL SINGLE LENS REFLEX CAMERA. SECTION 6 ADJUSTMENTS AUTO-ADJ VERSION 1.3 2007.10 PART#(9-852-130-54)



Back to : SONY DSLR-A100 SECTION 6 | Home

DSLR-A100
Ver. 1.3 2007.10 SECTION 6 Auto-ADJ
Revision History ADJUSTMENTS

Link
Before starting adjustments SERVICE MODE
To activate without exterior parts CAMERA LOG
Required adjustment, setting and confirmation LCD ALL SEGMENT ON
items after repairing (exchanging parts)
FLASH LEVEL SHIFT
Related adjustment and required setting items
LIGHT SOURCE-A MAINTENANCE
List of service tools



ADJUSTMENTS CHECK LIST
PREPARATIONS BEFORE ADJUSTMENTS CONDITION OF MEASURE AND APPRECIATION

CAMERA SYSTEM ADJUSTMENTS SETTING OF PHOTOSHOP

VIDEO SYSTEM ADJUSTMENTS SCREEN DUST

LCD SYSTEM ADJUSTMENTS STANDARD

OSD LANGUAGE SETUP

ERROR CODE ON ADJUSTMENT PROGRAM




· Use this Service Manual together with the DSLR-A100 Adjustment Program (DSLRadj_cs.exe).

· Preparing the DSLR-A100 adjustment program
· Precaution on Replacing the AM-001 Board




2007J0500-1
DSLR-A100_ADJ © 2007.10
9-852-130-53 Sony EMCS Co. Published by Kohda TEC
TABLE OF CONTENTS
Section Title Page
6. ADJUSTMENTS
Before Starting Adjustments ····················································· 6-1
1. To Activate without Exterior Parts ········································ 6-2
2. Required Adjustment, Setting and Confirmation Items after
Repairing (Exchanging Parts) ··············································· 6-3
3. Related Adjustment and Required Setting Items ·················· 6-5
4. List of Service Tools ····························································· 6-6

6-1. Adjustments ······································································· 6-8
1-1. Preparations Before Adjustments ······································· 6-8
1-2. Camera System Adjustments ··········································· 6-14
1-3. Video System Adjustments ·············································· 6-38
1-4. LCD System Adjustments ················································ 6-40
1-5. OSD Language Setup ······················································· 6-42
1-6. Error Code on Adjustment Program ································ 6-43

6-2. Service Mode ··································································· 6-50
2-1. Camera Log ······································································ 6-50
2-2. LCD All Segment ON ······················································ 6-52
2-3. Flash Level Shift ······························································ 6-52
2-4. Light Source-A Maintenance ··········································· 6-53

6-3. Check List ········································································ 6-54
3-1. Condition of Measure and Appreciation ·························· 6-54
3-2. Setting of Photoshop ························································ 6-55
3-3. Screen Dust ······································································ 6-56
3-4. Standard ··········································································· 6-57
* The AF assist chart is shown on page 6-64.




DSLR-A100_ADJ
--2--
SECTION 6
ADJUSTMENTS

Before starting adjustments

Precaution on Replacing the AM-001 Board
When the AM-001 board was replaced, perform "Firmware Rewriting" and then make all adjustments, and finally
perform "OSD Language Setup".




Firmware Rewriting
Note 1: Use the AC adapter or fully charged battery whenever rewriting the firmware.
Do not remove the battery or AC adapter while the Access lamp is lighting.
Otherwise, the firmware update from the CF card will fail.

1. Copy all files in the "System" folder in the "DSLR-A100 Firmware CD" to the route directory of the CF card.
2. Turn off the POWER switch of the camera, and insert the "Firmware Update" CF in the camera.
3. Set the AC adapter (battery).
4. Turn on the POWER switch while pressing the Lens Remove button.
5. After the Access lamp turns on, release the Lens Remove button, and the firmware update from the CF card will
start.
6. In about 2 minutes, the access lamp will turn off or blink to indicate that the update has completed.

Note 2: As the camera does not operate when the firmware update completed, remove and install the battery.




DSLR-A100_ADJ
6-1
1. To activate without exterior parts

Short-circuit the pattern-A of FP-528 flexible board with solder.
When using replacement FP-528 flexible board, no need to short these patterns because it has pattern-B.
Note: Before installing BACK COVER ASSY, be sure to unsolder the pattern-A or to cut the pattern-B.



FP-528 flexible board


Pattern-A




Pattern-B




Cut




DSLR-A100_ADJ
6-2
2. Required adjustment, setting and confirmation items after repairing (exchanging parts)

Adjust, set and confirm as the following table when the following parts are removed (exchanged).
Follow the steps from the upper line to adjust.


PARTS





AM-001 BOARD COMPLETE




FP-528 FLEXIBLE BOARD
MAIN CAPACITOR UNIT
REFLECTIONS UNIT




AF MODULE UNIT
APERTURE UNIT




POWER UNIT
CCD UNIT
SHUTTER
Removed


Removed


Removed


Removed


Removed


Removed


Removed


Removed


Removed
Replaced


Replaced


Replaced


Replaced


Replaced


Replaced


Replaced


Replaced


Replaced
ADJUSTMENT and
CHECK


z z z z z z z z z z z z z z z z z z
z z z
z z z z
z z z z
z z z z z z z z
z z z z z z z z z z z z z z z z z z
z z z z z z z z
z z z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z
z z z z
z z
z z z
z z z
z z
z z z
z z z z z z
z z
z z
z z
z z
Resolution Check z z z z z z z z z z z z z z z z z z
AE Check (Regular Light) z z z z z z z z z z
AE Check (Flash Light) z z z z z z z z z z z
Grayscales z z
Color Reproduction z z
Current Consumption z z z z z z z z z z z z z z z z z z
BC Voltage z z

Table 6-1-1 (1)

DSLR-A100_ADJ
6-3
PARTS





Removed


Removed


Removed


Removed


Removed


Removed


Removed


Removed


Removed
Replaced


Replaced


Replaced


Replaced


Replaced


Replaced


Replaced


Replaced


Replaced
ADJUSTMENT and
CHECK


z z z z z z z z z z z z z z z z
z z
z z z z
z z z z
z z z z z z
z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z
z
z z z z z




z z z z z


z z z z z z




z
z z z z
Resolution Check z z z z z z z z z z z z z z z z z z
AE Check (Regular Light) z z z z z
AE Check (Flash Light) z z z z z z z
Grayscales
Color Reproduction
Current Consumption z z z z z z z z z z z z z z z z z z
BC Voltage

Table 6-1-1 (2)




DSLR-A100_ADJ
6-4
3. Related adjustment and required setting items

When each adjustment or setting is operated, be sure to follow the related adjustment and setting items listed blow.
Number : Related adjustment items. Adjust and set in order of the number.
× : Related adjustment items. However, these items mean not to adjust the adjustment order is different (the adjustment should
be completed).
None : Unrelated adjustment and setting items (possible to adjust and set solely).

RELATED
ADJUSTMENT
ITEM




AORI&CENTER




DEFECT PIXEL
PRETRIGGER




SHAKE GAIN
FREQUENCY




PITCH, YAW



FLATNESS




CCD GAIN



BI FLASH
SERVO

GYRO




VOUT
AREA
ADJUSTMEN
PI-PR




LCD
WB
T ITEM
VB




AE
EZ
SS
VB

PI-PR 1

FREQUENCY 1 2

SERVO X 1 2

GYRO X X 1

AORI&CENTER X X 1 2 3

SS

AREA (1) 3 2

PITCH, YAW (1) 3 2

EZ X X

FLATNESS X X 1

PRETRIGGER X

AE 1

CCD GAIN X X 1 2 3

DEFECT PIXEL X 1 2

BI FLASH X

WB X 1

SHAKE GAIN X X X X X

VOUT

LCD


Table 6-1-2

When AM-001 board is exchanged for new one, setting of camera is sometimes changed.
1. Flash charge is prohibited.
* After Setting of OSD LANGUAGE, Flash charge is automatically allowed.
2. Every time you remove and insert the battery, the aperture diaphragm and AF coupler operates.
* After Setting of OSD LANGUAGE, this setting is automatically canceled.




DSLR-A100_ADJ
6-5
Ver. 1.3 2007.10


4. List of service tools
· Oscilloscope · Master body (Note 1)
· Regulated DC power supply · All white chart (Note 2)
· Digital multi meter · Flood lamp
· Variable transformer
· Hexangular wrench (1.5) or hexangular screwdriver
· Tripod

Note 1: Besides the camera to be adjusted, prepare the DSLR-A100 that satisfies the following conditions and use it as a master body.
· It should operate normally (must satisfy the specifications)
· It is in the factory setup state (already adjusted in the factory)
Note 2: Use the back side of the AF chart, etc. as an all-white chart.

J-1 J-2 J-3


Personal computer USB cable Back ground paper
(Note 3) 1-833-062-12 J-2501-130-A



J-4 J-5 J-6


Luminance box DSC shutter tester Luminance meter
J-6082-581-A J-6082-582-A LS-100
J-6082-583-A



J-7 J-8 J-9


Chroma meter Macbeth color Vibration tester
CL-200 checker J-6082-588-A
J-6082-584-A J-6082-585-A (Note 4)



J-10 J-11 J-12


Master lens for shake Shake offset Light balance filter
J-6082-589-A chart II LB200
J-6082-590-A J-6082-591-A



J-13 J-14 J-15


Preset tester Preset signal AF chart I
J-6082-592-A adaptor J-6082-594-A
J-6082-593-A



Fig. 6-1-1 (1)

Note 3: PC for use
The PC loaded on either Windows 2000 Professional or XP and USB terminal originally
40MB or more of available memory and 15MB or more of available hard-disk space
VGA or more monitor capable of displaying at least 32,000 colors.
Note 4: The power supply for the vibration tester is 100V. If the 100V power supply is not available, use the variable transformer to
adjust the power supply to 100V.




DSLR-A100_ADJ
6-6
Ver. 1.3 2007.10



J-16 J-17 J-18


AF chart II AF chart III AE master lens
J-6082-595-A J-6082-596-A J-6082-597-A




J-19 J-20 J-21


AF master lens AF-Y, P adjuster X-cable II
J-6082-598-A J-6082-599-A J-6082-600-A




Chart in the Box
J-22 J-23 J-24


Code with connector
(USB, AV) DSLR power supply
(Note 5) adaptor Adjustment unit
J-6082-624-A of CCD perspec
J-6082-603-A (Note 6)

J-25 J-26 J-27
AC adaptor/charger
AC-VQ900AM Connection code
1000 mm Collimator
1-479-824-13/34 (JIG)
110V: J-6082-604-A
(Note 7) J-6082-638-A
240V: J-6082-604-B



J-28 J-29 J-30


Fluorescent lamp Inverter type
Resolving power (Specified color fluorescent light stand
chart wide rendering) J-6082-643-A
J-6082-637-A J-6082-642-A


J-31

Tungsten lamp
J-6082-644-A
(Note 8)




Fig. 6-1-1 (2)

Note 5: Contact our service headquater of each area how to get the code with connector (USB, AV).
Note 6: The power supply for the adjustment unit of CCD perspec is 100V. If the 100V power supply is not available, use the variable
transformer to adjust the power supply to 100V.
Note 7: 1-479-824-13 (for J model)
1-479-824-34 (for Except J model)
Note 8: The power supply for the tungsten lamp is 100V. If the 100V power supply is not available, use the variable transformer to adjust
the power supply to 100V.




DSLR-A100_ADJ
6-7
Ver. 1.3 2007.10


6-1. ADJUSTMENTS

1-1. PREPARATIONS BEFORE ADJUSTMENTS
1-1-1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments.
1. Mode dial ..................................................... M
2. Focus mode switch ....................................... MF
3. Super SteadyShot switch .............................. OFF

1-1-2. Connection
Connect the camera and PC with the USB cord according to Fig. 1.




DC-IN terminal




To DC-IN terminal To VIDEO/USB jack

PC
AC IN

AC adaptor/charger
AC-VQ900AM
(1-479-824-13/34)
(Note)

USB cable
(1-833-062-12)




To USB connector



Fig. 1

Note: 1-479-824-13 (for J model)
1-479-824-34 (for Except J model)




DSLR-A100_ADJ
6-8
1-1-3. Preparing the DSLR-A100 adjustment program (DSLRadj_cs.exe)
DSLR-A100 Adjustment Program enables adjustment of DSLR-A100

1. PC for use
The PC loaded on either Windows 2000 Professional or XP and USB terminal originally
40MB or more of available memory and 15MB or more of available hard-disk space
VGA or more monitor capable of displaying at least 32,000 colors

2. Installation of the DSLR-A100 adjustment program
Extract the file compressed in the ZIP format (DSLR-A100.zip). Execute the extracted file (DSLRadj_csSetup.msi), and the installer will
start. Install the program following the instructions given on the installer screen.
· DSLR-A100 Adjustment Program (DSLRadj_cs.exe)
· Flash Adjustment Program (FlashAdjustment.exe)
· Lens Adjustment Program (LensAdjustment.exe)


3. Installation of the USB driver
1. Connect the camera and PC with the USB cord with connector, and then set camera to adjustment mode.
Refer to "Starting up the DSLR-A100 adjustment program (in the adjustment mode)".
2. PC detects the hardware, "Found New Hardware Wizard" is appeared.
3. "What do you want the wizard to do?" is displayed, select "Install from a list or specific location", and then click "Next". (Fig. 1)




Fig. 1

4. Select "Don't search. I will choose the driver to install." and then click "Next". (Fig. 2)




Fig. 2




DSLR-A100_ADJ
6-9
5. Click "Have Disk...". (Fig. 3)
Note: At this time, do not click "Next".




Fig. 3

6. Click "Have Disk....", and the following screen will be displayed. Click "Browse...", and after selecting the folder "C:\Program Files\Sony
AMC\DSLRadj_cs\USB" folder, click "OK". (Fig. 4, Fig. 5)




Fig. 4 Fig. 5
7. At this time, when you click "Next", the installation starts. (Fig. 3)
8. "The wizard has finished installing the software for:" is displayed and installation complete. (Fig. 6)




Fig. 6



4. Confirmation after installation
1. Right click on "My Computer" icon and select "Properties".
2. Select "Hardware" tab and click "Device Manager" button.
3. Check whether "Universal USB Driver (USB ADJ)" is displayed under the tree of "USB device for UUSBD".


5. Make CF card for Adjustment (Used for starting adjustment mode of camera)
1. Insert the "DSLR-A100 Firm CD" into the CD-ROM drive of PC.
2. Copy "ram.bin" in "Adj Firm" folder of CD-ROM to the root of CF card.




DSLR-A100_ADJ
6-10
1-1-4. Starting up the DSLR-A100 adjustment program (in the adjustment mode)

Outline
Connect the camera and PC with USB cable and start up the camera in the "adjustment mode."
"Adjustment mode" means the condition of that the camera can contact with the DSLR-A100 adjustment program in the PC.

1. Starting up the DSLR-A100 adjustment program (in the adjustment mode). Method 1
1. Connect the camera and PC with the USB cord with connector.
2. Set the mode dial of camera to "M".
3. Turn the POWER switch of the camera to OFF, then turn the POWER switch to ON while pressing the shutter button halfway down
with pressed the "v" button of controller keys and MENU buttons.
4. Check that the remaining number of recordable images on the LCD monitor is "BBBB".
Or, the display of In-F (viewfinder) becomes "ASIC 88".
Note: When "BBBB" is displayed, the camera activates in the adjustment mode. (Fig. 1)




Fig. 1
5. Start up the DSLR-A100 adjustment program, "DSLRadj_cs.exe".
"Please select camera code." appears. (Fig. 2)




Fig. 2




DSLR-A100_ADJ
6-11
6. Select "DSLR-A100" from "CAMERA MODEL" in the window, according to the display.
"Please connect DSLR-A100 and click START!" appears. (Fig. 3)




Fig. 3


7. Click the "CONNECT" button.
"FIRMWARE VERSION READ-OUT has completed!" appears. (Fig. 4)




Fig. 4

2. Starting up the DSLR-A100 adjustment program (in the adjustment mode). Method 2
In the condition that a function button cannot be used such as Aori adjustment, start up the camera using a CF card with adjustment
program.
1. Insert the CF card with POWER switch on, no power supply (battery), and "M" mode.
2. Connect the camera and PC with the USB cord with connector.
3. Connect the AC adaptor (power supply) while pressing the lens release button.
4. Release the lens release button after access lamp lit, the camera starts from the CF card.
Frame counter will be "BBBB" and the camera starts up in adjustment mode. (Fig. 1)
Or, the display of In-F (viewfinder) becomes "ASIC 88".
5. Same as 5, 6, 7 of the above method 1.


3. Quitting the DSLR-A100 adjusting program and cancel adjustment mode of camera
1. Click "END" in the window of the DSLR-A100 adjustment program.
2. Remove the AC adapter.




DSLR-A100_ADJ
6-12
4. Adjustment items in the DSLR-A100 Adjustment Program
PI-PR
FREQUENCY
SERVO
GYRO
AORI & CENTER
SS
AF (AREA, PITCH/YAW)
FLATNESS
EZ
PRETRIGGER
AE
CCD GAIN
DEFECT PIXEL
BI FLASH
WB
SHAKE GAIN
V OUT
LCD
FLASH LEVEL
OSD LANGUAGE




DSLR-A100_ADJ
6-13
1-2. CAMERA SYSTEM ADJUSTMENTS

1. CCD inclination adjustment / repair

Check
1. Use a copy stand, or place a mirror on the wall and adjust the accuracy so that the camera is opposed to its mirror image.
2. Use the AE master lens for inspection.
3. Obtain the tilt angle with the Photoshop, and perform as follows according to the angle:
For the angle above +/­1.0 degree, be sure to repair.
For the angle above +/­0.5 degree and less than +/­1.0 degree, repair according to the user's required level.
For the angle below +/­0.5 degree, re-check and it is within the specification.

Adjustment
1. Remove the eccentric pin stopper. (Fig. 1)
2. Check, and adjust the hexagonal eccentric pin. (Fig. 2)
*The eccentric pin can be rotated 60 degree (CCD tilt 0.42 degree) in clockwise and counterclockwise directions respectively from the
neutral position.
Adjustment exceeding 60 degree is impossible. (Eccentric pin stopper cannot be installed)
If an image tilts toward the lower right, rotate the eccentric pin 60 degree clockwise.
If an image tilts toward the lower left, rotate the eccentric pin 60 degree counterclockwise.


Eccentric Pin


Eccentric Pin Stopper




Eccentric Pin
(Neutral Position)


Fig. 1 Fig. 2




DSLR-A100_ADJ
6-14
Ver. 1.3 2007.10


Repair (when it cannot be adjusted by the above adjustment method)
1. Disassemble until the CCD Set can be removed.
2. Cut at two bosses for positional reference and directional reference of the CCD holder and the radiation plate. (Fig. 3)
3. Attach an insulation sheet to the terminal of CCD Set. (Prevention of short-circuit with CCD holder)
4. Assemble the CCD Set by shifting it by the amount of play
If an image tilts toward the lower right, shift clockwise the CCD Set by the amount of play.
If an image tilts toward the lower left, shift counterclockwise the CCD Set by the amount of play.
The double-sided adhesive tape on the LPF, if shifted by the amount of play, can be corrected in a range of about +/­0.7 degree
maximum.
In this case, however, prepare the service part "Slider Unit: A-1246-028-C" and modify it as described in step 2 above to make it as a
jig, and then shift the LPF on the jig (for prevention of damage to the Steadyshot Set of user's camera).
5. Assemble up to the exterior.
6. Check the tilt following the checking method.
*If not within +/­0.5 degree, replace the "Slider Unit: A-1246-028-C" and recheck.
7. After the repair completed, perform "CCD Aori and Center Adjustment" and "Steadyshot Sensitivity Adjustment".


Two bosses




Fig. 3




DSLR-A100_ADJ
6-15
2. Viewfinder Back Adjustment

Equipment Required
1000 mm Collimator
AE Master Lens

Adjustment
1. Set the green filter and the chart in the collimator.
2. Set up the camera as in Fig. 1, so that the chart is at the center of viewfinder.
3. Set Master Lens to infinity.
4. Check that the chart is in focus.
If not, Select one or two VB Washers, and install Washer(s) as in Fig. 2.
In case of front focus: Make VB Washers thinner.
In case of rear focus: Make VB Washers thicker.


Chart
Green filter




1000 mm collimator
AE master lens




Fig. 1


VB WASHER
Part No. T = (mm)
A 2-689-369-01 0.05
B 2-689-370-01 0.1
C 2-689-371-01 0.15
D 2-689-372-01 0.2




FRESNAL SPRING
VB WASHER



FOCUSING SCREEN




Fig. 2




DSLR-A100_ADJ
6-16
3. Adjustment of the PI-PR

Required equipment
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)

Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to "Starting up the DSLR-A100 adjustment program (in the adjustment mode)".
2. Click "PI-PR" of the adjustment menu. "Does it adjust?" appears.
3. Click "YES". Automatic adjustment starts.
4. The adjustment is completed when "OK" is displayed on the adjustment menu.


4. Adjustment of the frequency for camera shaking (FREQUENCY)

Note: During the adjustment, put the body on a flat place and do not give it a shaking or vibration.

Required equipment
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)

Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to "Starting up the DSLR-A100 adjustment program (in the adjustment mode)".
2. Click "FREQUENCY" of the adjustment menu. "Does it adjust?" appears.
3. Click "YES". Automatic adjustment starts.
4. The adjustment is completed when "OK" is displayed on the adjustment menu.


5. Adjustment of the servo for camera shaking (SERVO)

Note: During the adjustment, put the body on a flat place and do not give it a shaking or vibration.

Required equipment
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)

Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to "Starting up the DSLR-A100 adjustment program (in the adjustment mode)".
2. Click "SERVO" of the adjustment menu. "Does it adjust?" appears.
3. Click "YES". Automatic adjustment starts.
4. The adjustment is completed when "OK" is displayed on the adjustment menu.


6. Adjustment of the gyro for camera shaking (GYRO)

Note: During the adjustment, put the body on a flat place and do not give it a shaking or vibration.

Required equipment
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)

Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to "Starting up the DSLR-A100 adjustment program (in the adjustment mode)".
2. Click "GYRO" of the adjustment menu. "Does it adjust?" appears.
3. Click "YES". Automatic adjustment starts.
4. The adjustment is completed when "OK" is displayed on the adjustment menu.




DSLR-A100_ADJ
6-17
7. Setting for the adjustment of CCD AORI & CENTER
Install the body and the adjustment unit of CCD perspec by the method given below, and perform the adjustment of CCD AORI &
CENTER.

Required equipment
PC with preinstalled the DSLR-A100 adjustment program
Adjustment unit of CCD perspec
Master body
USB cable
AC adaptor/charger (AC-VQ900AM)
Hexangular wrench (1.5) or hexangular screwdriver


Installation of body and adjustment Unit of CCD perspec
1. Align the boss in the lens mount of the body with a slit in the mounting surface of the adjustment unit of CCD perspec.
2. Ensure that no gap exists between the lens mount and the mounting surface, and then erect the lever to fix the body. (Fig. 1)


2 Turn the lever




1 Align the position




Fig. 1




DSLR-A100_ADJ
6-18
8. Adjustment / Checking of CCD AORI & CENTER

Outline
Adjust the position and tilt of the CCD.
For the installation of jigs, refer to "Setting for the adjustment of CCD AORI & CENTER".

Preparation of the adjustment
When CCD sensor module is out of position after replacing CCD MODULE ASSY, tighten three AORI adjusting screws until
they stop, then evenly loosen them by 3 turns.
1. Perform this adjustment without REAR COVER UNIT.
2. Set Master body and Adjustment unit of CCD perspec.
Refer to "Setting for the adjustment of CCD AORI & CENTER".

Procedure of CCD AORI & Center Adjustment
1. Set the Master body to adjustment mode.
Refer to "Starting up the DSLR-A100 adjustment program (in the adjustment mode)".
2. Click "AORI & CENTER" in adjustment menu.
3. Click "DSLR-A100" when "Please select master data" appears. (Next page Fig. 1)
4. Click MASTER BODY "AORI & CENTER" in AORI & CENTER Adjustment menu. (Next page Fig. 2)
(Data readout starts. During the readout, the camera releases the shutter twice.)
5. "Setting Data of master body has complete!" is displayed, data readout completed.
6. Click CHECK "AORI" and check the data.
7. Click "END" in AORI & CENTER Adjustment menu.
8. Click "END" in adjustment menu.
Note: Do not close the adjustment screen. Otherwise, the Master body data will be lost.
9. Exchange the Master camera for target camera.
10. Set the target to adjustment mode.
11. Click "AORI & CENTER" in adjustment menu.
12. Click "DSLR-A100" when "Please select master data" appears.
13. Click ADJUSTMENT "CENTER" in AORI & CENTER Adjustment menu. "Does it adjust?" appears.
14. Click "YES".
(Adjustment starts. During the adjustment, the camera releases the shutter three times.)
15. "CENTER Adjustment has completed!" appears when completed.
16. Click ADJUSTMENT "AORI" in AORI & CENTER Adjustment menu. "Does it adjust?" appears.
17. Click "YES".
(Adjustment starts. During the adjustment, the camera releases the shutter once and the Aori Adjustment window appears.)
18. Check the numbers displayed in Aori Adjustment window, whether value of "C" and "dPI" is in the range of standard value.
(Next page Fig. 3)


Standard value of C: Between -10 and 10
Standard value of dPI: Between -10 and 10

If displayed value is out of range, perform the following adjustment.
Turn AORI adjusting screws following the direction in Aori Adjustment window (Next page Fig .4)

19. By clicking "RETRY", repeat step 18 until displayed value is within the standard.
20. If the result is within the standard, click "OK" in AORI adjustment menu to complete.


Perform"Resolving Power" check according to the "Check List", after finishing adjustment.
Repeat adjustment of CCD center position and AORI until the result of this check satisfies the standard.




DSLR-A100_ADJ
6-19
Fig. 1




Fig. 2 Fig. 3




Fig. 4
Procedure of CCD AORI Checking
1. Set the Master body to adjustment mode.
Refer to "Starting up the DSLR-A100 adjustment program (in the adjustment mode)".
2. Click "AORI & CENTER" in adjustment menu.
3. Click "DSLR-A100" when "Please select master data" appears. (Fig. 1)
4. Click MASTER BODY "AORI & CENTER" in AORI & CENTER Adjustment menu. (Fig. 2)
(Data readout starts. During the readout, the camera releases the shutter twice.)
5. "Setting Data of master body has complete!" is displayed, data readout completed.
6. Click CHECK "AORI" and check the data.
7. Click "END" in AORI & CENTER Adjustment menu.
8. Click "END" in adjustment menu.
Note: Do not close the adjustment screen. Otherwise, the Master body data will be lost.
9. Exchange the Master camera for target camera.
10. Set the target to adjustment mode.
11. Click "AORI & CENTER" in adjustment menu.
12. Click "DSLR-A100" when "Please select master data" appears.
13. Click CHECK "AORI" in AORI & CENTER Adjustment menu.
(Checking starts. During the checking, the camera releases the shutter once and the Aori Adjustment window appears.)
14. Check the numbers displayed in Aori Adjustment window, whether value of "C" and "dPI" is in the range of standard value. (Fig. 3)

Standard value of C: Between -30 and 30
Standard value of dPI: Between -30 and 30


DSLR-A100_ADJ
6-20
9. Manual Set SS & X-Sync. Time-lag Check

Equipment Required
DSC shutter tester
AC adaptor/charger (AC-VQ900AM)
X-cable II

Manual SS Check
1. Set up the equipment as in Fig. 1.
2. Release the shutter at each shutter speed, and check that reading meets the Table-1 below.

X Sync. Time-Lag Check
1. Set up the equipments as in Fig. 1.
2. Release the shutter and check that reading meets the Table-2 below.

Manual SS Check X-Sync. Time-Lag Check
DSC Shutter Tester DSC Shutter Tester
1 ms
FUNC: EXP FUNC: X
2 ms CAMERA CAMERA
Exposure mode: M Exposure mode: M
A
Super SteadyShot: OFF SS: 1/160
B Super SteadyShot: OFF
C
BOUND
EXP X RUN
POSITION
HASTY
FUNCTION




B-Range



X-cable II




Fig. 1


Period Tolerance
SS
(ms) (ms)
1/4000 0.244 0.156 ­ 0.383
1/2000 0.488 0.333 ­ 0.714
1/1000 0.977 0.793 ­ 1.202
1/500 1.950 1.590 ­ 2.40
1/250 3.910 3.17 ­ 4.81
1/125 7.810 6.35 ­ 9.62
1/60 15.60 12.7 ­ 19.2
1/30 31.30 29.2 ­ 33.5
1/15 62.50 58.3 ­ 67.0
1/8 125 117 ­ 134
1/4 250 233 ­ 268
1/2 500 467 ­ 539

Table - 1

Shutter speed Item Allowance
1/160 X-sync delay time 0.5 ms or longer
(Super SteadyShot: OFF) From X ON to the 2nd curtain appearance 2.0 ms or longer
1/125 X-sync delay time 0.9 ms or longer
(Super SteadyShot: ON) From X ON to the 2nd curtain appearance 2.0 ms or longer

Table - 2
DSLR-A100_ADJ
6-21
10. Adjustment Manual Set SS

Equipment Required
PC with preinstalled the DSLR-A100 adjustment program
DSC shutter tester
USB cable
AC adaptor/charger (AC-VQ900AM)

Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to "Starting up the DSLR-A100 adjustment program (in the adjustment mode)".
* Turn off the Super SteadyShot switch.
2. Click "SS" of the adjustment menu. "Does it adjust?" appears. Click "YES".
3. "Execute 1st release?" appears. Click "OK".
4. Repeat step 3 to perform shutter release three times, and then calculate an average of readings at B-Range (SS:1/4000).
5. Input SS average [µs] in the window (Fig. 1).
6. If the input value is within the standard, "OK" appers and adjustment is completed.
If the input value is out of standard, repeat from step 3.




Fig. 1



Standard Value: 0.265 ms ­ 0.305 ms




DSC Shutter Tester
1 ms
FUNC: EXP
2 ms CAMERA
A
Exposure mode: M
SS: 1/4000
B Super SteadyShot: OFF
C
BOUND
EXP X RUN
POSITION
HASTY
FUNCTION




B-Range




Fig. 2




DSLR-A100_ADJ
6-22
11. Preparation before AF (AREA, Pitch Yaw, FLATNESS, EZ) adjustment

Note: After replacing CCD MODULE ASSY and/or MIRROR BOX ASSY or its relative parts, always perform AF Area Adjustment to
EZ Adjustment.
If customer says focus fucntion is not normal, perform this adjustment too.

Preparations
The following items should have been completed before starting AF adjustment.
1. Peform this adjustment without FRONT COVER ASSY, after disassemble.
2. When CCD sensor module is out of position after replacing CCD MODULE ASSY, tighten three AF adjusting screws until they stop,
then evenly loosen them by 0.4mm (1.14 turns).

Equipment Required
PC with preinstalled the DSLR-A100 adjustment program
AF master lens
AE master lens
AF-Y, P adjuster
USB cable
AC adaptor/charger (AC-VQ900AM)
Luminance box
AF chart I
AF chart II
AF chart III
Hexangular wrench (1.5) or hexangular screwdriver
Inverter type fluorescent lamp (EZ check and adjustment)
Flood lamp (AF Area)




DSLR-A100_ADJ
6-23
12. AF Area Adjustment

Adjustment
1. Set up the equipment as in Fig. 1.
2. Set the camera to the a