Found: 12
Bush
2867NTX
Field collapse & no sound
No LT supply to jungle chip as R818 22k 2w o/c
14-09-04
Bush
2867NTX
Field collapse with fb lines on top half
Dry joints at R818 (22kohm, 2W), R810
14-09-04
Bush
2867NTX
Install menu & chan 1 posn locked
Reqs password - if the password is forgotten then use 734. This will allow you to unlock the channels. To open the install menu however you must unlock "all" the locked channels. If you find that you cannot enter the tuning menu one or more of the 100 channels is locked, so search through them all and make sure they are all unlocked.
14-09-04
Bush
2867NTX
Locking codes faulty
EEPROM faulty
14-09-04
Bush
2867NTX
no sound
check TDA1521A o/p chip & R811 4R7 also replace C365/366 1000µ. C374 470nf leaky in this case
14-09-04
Bush
2867NTX
(11AK12)
Dead - chopper tfmr failure
Replace T2.5A fuse, BUZ90 (used 2SK1643), R801 2R2 5W cement resistor, plus a 0.5R 1W metal oxide had gone o/cThe chopper transformer is obtained from CPC under part number AB4040905110 for ?5.08 + VAT and comes with a small mod kit (details below) . Transformer was a Teleson , now made by Eldor. R812 - change to 47R metal oxide, C809 - change to 220nF 63V MKT
14-09-04
Bush
2867NTX
11AK12
Dead with 150v present at LOPTr coll
No line dr - 12v supply low as D812 BYV27 leaky
14-09-04
Bush
2867NTX
11AK12
Dead with chopper trfmr s/c
Replacement trfmr comes as a kit pt no 30004541- also replace R812 47R 1w metal oxide & C809 220nF 63v
14-09-04
Bush
2867NTX
11AK12
Fluttery pic on certain scenes (after sm Tx replaced)
C608 10µ 350v
14-09-04
Bush
2867NTX
11AK19
Int off with smell of burning
dry joints chopper trfmr
14-09-04
Bush
2867NTX
11AK19
No line drive
R866 0R33 in series with 14v supply o/c (not shown on cct diag)
14-09-04
Bush
2867NTX
11AK19
Pic takes long time to appear - quicker if A1 adjusted
Check C608 10µ 250v reservoir cap for RGB stages by edge near LOPTx
14-09-04