Goodmans
C
530
Int pic - reverts to line collapse
LH01 int o/c pt no ACTI19433130A
14-09-04
Goodmans
C
530
St/by only
Glue on ribbon cable at control pcb conductive
14-09-04
Grundig
CUC
530
1
Child lock removal
Hold in vol + vol - prog - prog + when inputting the pin no
14-09-04
Grundig
CUC
530
1
Dead - fuse blown.
Chopper tran T644 s/c , D681 ( BYV38 ) leaky.
14-09-04
Grundig
CUC
530
1
DEAD FUSE BLOWN CHOPPER SC
D681 SC
14-09-04
Grundig
CUC
530
1
Field Collapse
D401 12v zener s/c and hi ht due to 2 x 47µ caps
14-09-04
Grundig
CUC
530
1
Int pic - sound ok
dry joints T568 tr heatsink - mech stressed
14-09-04
Grundig
CUC
530
1
no r/c
4 pin rec u/s - replace with 3 pin version
14-09-04
Grundig
CUC
530
1
OSD dim & outline only - ok when no sigs present
IC2541 TDA3566 col dec chip u/s
14-09-04
Grundig
CUC
530
1
R/C inop - no response from IR Rx
Replace IR unit TFMS4300 4 leg type, with TFMS5360 3 leg type not all 3 leg type will do
14-09-04
Grundig
CUC
530
3
No front or R/C controls aft couple of hours
IR Rx
14-09-04
Grundig
CUC
530
3
PS. Transistor blown. Changed chopper tr, and TDA4605, But they were blown again. Occasionally the set before blowing the smps may run for a while.
Check/Replace R632 270K Resistor.
14-09-04
Grundig
CUC
530
5
No i/p via scart
IC2350 TDA5931-5 on IF pcb
14-09-04
Grundig
CUC7
530
No H drive
(BC848) which is used as a line protector.
14-09-04
ITT
FX4
530
Blows LOPTr when sw on from st/by
C734 10µ 450v in psu & 4.3nF 1.6kv buffer cap in line scan - check HT = 105v (17")
14-09-04
Philips
25PT
530
1
Ticking noise / Whistling, no start up
Change C2550 680nF/250V cap, however normal it may look visually. Also change 1534 fuse . This time this cap had also taken D6561 68V Zener diode with it. ( It was shorted)
14-09-04
Philips
GR2.4 29PT
530
1/05
Dead with mains I/p fuse o/c
Check for dry joints PSU pri
14-09-04