| Make | Model | Problem | Solution | Date |
| | | |
| Found: 20
|
| Finlandia | C66CZ6 | Tuning store/lock code - press within 5 sec | A,0/10+,Chan-up,Store | 14-09-04 |
| Finlandia | C66CZ7 | Tuning store/lock code - press within 5 sec | A,0/10+,Chan-up,Store | 14-09-04 |
| Finlandia | C66DZ6 | Tuning store/lock code - press within 5 sec | A,0/10+,Chan-up,Store | 14-09-04 |
| Finlandia | C66DZ7 | Tuning store/lock code - press within 5 sec | A,0/10+,Chan-up,Store | 14-09-04 |
| Finlandia | C66FZ6 | Tuning store/lock code - press within 5 sec | Red,0/AV,Step,Store | 14-09-04 |
| Finlandia | C66FZ7 | Tuning store/lock code - press within 5 sec | Red,0/AV,Step,Store | 14-09-04 |
| Finlandia | C66HZ6 | Tuning store/lock code - press within 5 sec | A/Red,0/AV,Step,Store | 14-09-04 |
| Finlandia | C66LZ6 | Int pic | Dry joints Tr TA17 (middle back) | 14-09-04 |
| Finlandia | C66LZ6 | No sound | 8R2 res suspect feeding base of Tp2 | 14-09-04 |
| Granada | C66GZA | Field collapse | IC501 TDA3654 fop chip had failed; C574 100µ 50v low cap | 14-09-04 |
|
|
| Granada Hita | C66GZA | Field collapse - the TDA3654 field output chip IC5 | C574 ( 100uF , 50V ) | 14-09-04 |
| Sharp | 4BSC 66AS05H | blank raster, OSD ok | SMD Q400 2SC2412/BC848 s/c (video buffer transistor) | 14-09-04 |
| Sharp | 4BSC 66AS05H | Dead | Lop tr Q600 2SD1546 u/s. Line drive wfm at C607 cramped - Q606 2SC2412 sm leaky | 14-09-04 |
| Sharp | 4BSC 66AS05H | Dead - LOPTr 2SD1546 failed | Replacement only lasted days - IC800 MC44002P line drive pin 12 only 1v instead of 3v - chip faulty. Also check state of Q601 2SC2271 dr tr & Q606 pre driver tr | 14-09-04 |
| Sharp | 4BSC 66AS05H | Dead - no line drive | IC800 MC44002 jungle chip faulty | 14-09-04 |
| Sharp | 4BSC 66AS05H | Dead with ticking | LOPTr s/c due to dry joints scan coil plug | 14-09-04 |
| Sharp | 4BSC 66AS05H | excessive width with E-W error | L601 shorted turns (RCILP0104CEZZ) | 14-09-04 |
| Sharp | 4BSC 66AS05H | No E-W corr aft replacing TDA8170 FOP chip, R645 & C506 for tripping off | Q603 2SD1913S collector base leakage, and C603 4.7uF high ESR | 14-09-04 |
| Sharp | 4BSC 66AS05H | No line aft repairing dry joints scan coil & LOPTr s/c LEDs sw between Red/Green | leaky s.m. transistor Q606 [2SC2412] in the line
drive circuit. | 14-09-04 |
| Sharp | 4BSC 66AS05H | stuck in stby, when brought out LED goes green, quick burst of EHT, then shuts down with LED red | SMD Q606 2SC2412 leaky | 14-09-04 |