Make | Model | Problem | Solution | Date |
| | | |
Found: 134
|
Philips | FL2.16 | "NVM write protection enabled" message on screen. | Startup problem or 'NVM write protection enabled' message on screen
after replacement of NVM
(ST24C08CB1; 4822 209 32283) with a ST24C08CB6 (4822 209 33113).
Use as replacement the ST24C08 1 (9311 021 36682). | 14-09-04 |
Philips | FL2.16 | 100Hz cross | Possible solutions:
1. Interrupt on the SSP the 50Hz Y-signal, between pin 11 position
IC7324 (TDA4568) and pin 11 position IC7395 (TDA8443), by
deleting position 4302.
Repair the connection by means of a shielded cable of 16cm long,
m | 14-09-04 |
|
Philips | FL2.16 | 22AV1440 is switched on by external VCR when FL1 is switched off | Connect 4 diodes of type BAT 85 to inputs of IC7630 on SSP.
1 diode between pin 3/IC7630 and +5V, cathode to +5V.
1 diode between pin 5/IC7630 and +5V, cathode to +5V.
1 diode between pin 3/IC7630 and -8V, anode to -8V.
1 diode between pin 5/IC7630 and -8 | 14-09-04 |
Philips | FL2.16 | 50Hz buzz noticable through speaker | Check/replace IC7680 on the SSP - TDA8425, pseudo stereo IC.
(4822 209 63734).
| 14-09-04 |
Philips | FL2.16 | Adaption of Service Information FL93.05 | Adaption of Service Information FL93.05
---------------------------------------
From 93-06-24 onwards the definition of optioncode 4 has been
changed.
From this day onwards the definition is as follows:
1 TXT peaking filter on/off for LFR box (Scandina | 14-09-04 |
Philips | FL2.16 | After 1 hour blue picture. Last error code 07. | +13V supply a little low (11,7V)
Check IC7551 (LM358N; 4822 209 70672).
| 14-09-04 |
Philips | FL2.16 | After 10 minutes picture becomes red from right side | C2395 on the LSP poorly soldered.
| 14-09-04 |
Philips | FL2.16 | After a while raster various. (shaky) | Check C2410/2411 (150nF; 4822 121 41854) in raster oscillator.
| 14-09-04 |
Philips | FL2.16 | Antenna input: no sound. External input: sound O.K. | Check whether crystal 1602 (stereo decoder) 10MHz oscillates.
If not replace X1602 (4822 242 80276).
| 14-09-04 |
Philips | FL2.16 | Bad focus or focus varies in a new set or after CRT replacement | Possible solution:
Short circuit the focus and the G2 pins of the picture tube with the
aquadag coating. Switch the set on for approximately 5 seconds.
After this return the set to its original condition. Check if the
focus adjusted normally. If not repla | 14-09-04 |
Philips | FL2.16 | Bad geometrie on top and bottom of the picture. | Change the North/South correction panel into 3104 317 72810
(4822 212 31004).
The North/South correction panel has been changed. For service the
correct one will be delivered. | 14-09-04 |
Philips | FL2.16 | Bad pict. No menu. Dark bars over pict. Red pict. in dig.scan mode. | +5V was 4,3V instead of 5,1V.
IC7551 (LM358N 4822 209 70672) defective.
IC7209 (SAA7158 4822 209 31059) Bendic defective.
| 14-09-04 |
Philips | FL2.16 | Bad picture. Picture scrolls. No RC reaction. | +5V was 4,1V instead of 5,1V. Replace IC7551 (LM358N; 4822 209 70672)
| 14-09-04 |
Philips | FL2.16 | Bad synchronisation. | Bad line sync. pulses at C2219 on source selection.
Replace C2219 (220nF; 4822 122 32927)
| 14-09-04 |
Philips | FL2.16 | Blank picture. OSD not synchronised and too large, no TXT. | Check/replace memory IC 7900 (ST24C08CB1; 4822 209 32283).
| 14-09-04 |
Philips | FL2.16 | Blue picture, menu and TXT are OK. | Check IC7207 (SDA9205-2) LFR box (4822 209 31056).
| 14-09-04 |
Philips | FL2.16 | Both languages can be heard by Dual Nicam signals | For FL1-PTV change the software into V89; 4822 900 10732
For all other FL sets change the software into V88; 4822 900 10723
REMARKS :Introduced in production from week 9614 onwards. | 14-09-04 |
Philips | FL2.16 | BUX85F in mikroSOPS defective | Change the value of C2260 to 4n7F, replace 7270 with transistor
BD825 (4822 130 41746).
| 14-09-04 |
Philips | FL2.16 | Colored picture or picture is green/red, fly-back lines | Check zenerdiode 6450 on pin 19-IC7430 on the LSP. New diode must
be Philips (Telefunken does not work), 4822 130 81512
| 14-09-04 |
Philips | FL2.16 | Coloured spot on screen during switch-off | Replace R3037 by 1k3 (4822 051 10132).
REMARKS :
Introduced in production from week 9334 onwards.
| 14-09-04 |
Philips | FL2.16 | Colours not OK. No R-Y on test picture. | No R-Y on pin 1 TDA4650. C2385 (10NF; 4822 122 32442) is leaking.
| 14-09-04 |
Philips | FL2.16 | Correction | Correction
----------
All diagrams/partslists of the LFR box show on position 7244 an
Integrated Circuit with typenumber N74F74D.
However on this position an IC with typenumber N74F125D is used.
The codenumber for the correct N74F125D is: 5322 209 61857
| 14-09-04 |
|
Philips | FL2.16 | Correction to Product Survey 1993-4 | Correction to Product Survey 1993-4
-----------------------------------
Due to the introduction of new software (V67) an extra option bit
in option code 4 has to be set. For the following sets 32 has to be
added to option code 4:
25PT910A/01/19
25PT912A/0 | 14-09-04 |
Philips | FL2.16 | Correction to Product Survey 1996-4 | Correction to Product Survey 1996-4 (4822 727 21505)
----------------------------------------------------
On page PCS 41989 is mentioned at:
FL1.10 AG11 and higher: Control panel 4822 212 31708
FL1.17 AG20 : Control panel 4822 212 31708
FL | 14-09-04 |
Philips | FL2.16 | Correction to service information FL 95.01 | Correction to service information FL 95.01
------------------------------------------
Correction in the overview of 100Hz and Proscan boxen.
The replacement for service code 4822 212 30534 must be 4822 212 31231
The replacement for service code 4822 21 | 14-09-04 |
Philips | FL2.16 | Correction to service information FL 95.01 | Correction to service information FL 95.01
------------------------------------------
Correction in the overview of 100Hz and Proscan boxen.
The replacement for service code 4822 212 30534 must be 4822 212 31231
The replacement for service code 4822 21 | 14-09-04 |
Philips | FL2.16 | Correction to Service Manual | Correction to Service Manual
----------------------------
In service manual FL1/2.14, FL1/2.16, FL1.17 AA the code number of
the Scavem amplifier panel is wrong. The correct code number for
this panel is 4822 212 31469.
REMARKS :
The code number | 14-09-04 |
Philips | FL2.16 | Correction to service manual FLx.14/16/17 | Correction to service manual FLx.14/16/17 and FLx.24/26/27.
-----------------------------------------------------------
The code number of position 1200 (fuse 3,15 A) is wrong.
The correct code number is 4822 070 33152. This fuse is situated on
the LSP i | 14-09-04 |
Philips | FL2.16 | Correction to the Service Manual | Correction to the Service Manual
--------------------------------
In circuit diagram B on page 7 of the service manual
FL1.14/FL2.14/FL1.16/FL2.16 and FL 1.17 the resistors 3624 and 3625
are not drawn.
These resistors should be drawn on the position of 96 | 14-09-04 |
Philips | FL2.16 | Crazy behaviour: No response from RC or controls. | Other phenomenas: volume up/down, spontanuous service mode etc.
etc. in areas with TOP-teletext.
Replace control software by replacing EPROM IC7002 to version V82
(4822 900 10423). For easy mounting also the controlboard 7115
(on SSP) can be replaced by | 14-09-04 |