Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....
◦
register
◦
send pass
S
earch
B
rowse
U
pload
W
anted
D
atasheets
C
hassis2model
R
epair tips
F
ulltext search
C
ables & Connectors
R
epair tips
Electronic appliance repair tips database - TV (LCD,TFT,Plasma,Digital), Monitor, VCR, DVD recorder and player, Digital camera, Audio equipment, Microwave ovens, Phone systems, Computer repair
Make
Model
Problem
Solution
Date
Found: 45
Philips
NC3
Black raster - sound & OSG Ok.
IC TDA3565
14-09-04
Philips
NC3
Blank raster - sound ok
TDA3565 col dec chip
14-09-04
Philips
NC3
Bright Raster with fb lines - sound ok
TDA4505 faulty
14-09-04
Philips
NC3
Chopper tr blows at sw on
R418 o/c & check for dry joints in chopper & LOP ccts & R407 560k
14-09-04
Philips
NC3
CHOPPER TR SC
CHECK R407 560k
14-09-04
Philips
NC3
Dead
o/c mains sw - used Grundig type
14-09-04
Philips
NC3
Dead
chopper tr s/c dry joints T402
14-09-04
Philips
NC3
dead - 2A fuse o/c
4R7 dropper o/c, BUT11AF chopper tr s/c, dry joints chopper tfmr & others
14-09-04
Philips
NC3
Dead - blowing line output Tx BUT11AF Q501.
Dry joints on LOPTX especially pin 10.
14-09-04
Philips
NC3
Dead - blown chopper transistor.
R418 o/c.
14-09-04
Philips
NC3
Dead - chopper Q401 duff.
Check for drys at connections to chopper Tx T402.
14-09-04
Philips
NC3
Dead - went with bang
burnt print around on/off sw also blew Q400 BC337 s/c; D404, 411, 407, 410 1N4148 s/c
14-09-04
Philips
NC3
Dead chopper TR s/c R401 ( 4R7 ) o/c
Check for D/J around Chopper TX & LOPT
14-09-04
Philips
NC3
DEAD WHISTLES DISCONNECTING PIN 2 LOPT AND SET RUN
CHECK D2581 2582 8v2 ZENER OR THYRISTOR
14-09-04
Philips
NC3
Dead with whistle
OK on dummy load, Zener diodes 2581/2 8v2 leaky in crowbar trip cct
14-09-04
Philips
NC3
Field - lack of height
R581 3M9 hi res connected to 95v supply in TDA4505 cct
14-09-04
Philips
NC3
FIELD FOLDOVER
R556 HIGH ( 24k )
14-09-04
Philips
NC3
Goes into prot mode aft half an hour
100v HT had gone high - CNX62 opto coupler faulty
14-09-04
Philips
NC3
Horizontal lines & streaks
C2413 100µ 400v o/c
14-09-04
Philips
NC3
Int pic
R608 18R dry joint
14-09-04
Philips
NC3
Intermittent poor picture & garbled sound.
Channel change switch S300.
14-09-04
Philips
NC3
Monochrome pic with false line lock
Misshapen sandcastkle pulse caused by TDA4505 chip - also check 680k line pulse feed res
14-09-04
Philips
NC3
Motorboating sound with green raster
C2483 dry joints had damaged 5v reg 78M05
14-09-04
Philips
NC3
No col
Replace TDA3565 dec chip & adj R635 ref osc. To adj s/c pins 5 & 1 of chip
14-09-04
Philips
NC3
No colour
Try adjusting R635.
14-09-04
Philips
NC3
No colour - brightness/contrast inoperative.
IC TDA4505.
14-09-04
Philips
NC3
No pic - sound ok
No A1 volts - LOPTx faulty
14-09-04
Philips
NC3
No pic for first 2 hours
Replace TDA3565 dec chip & adj R635 ref osc. To adj s/c pins 5 & 1 of chip
14-09-04
Philips
NC3
No pic just blank raster - sound ok
Sandcastle pulse dist - break in print between R570 & SC gen o/p from IC pin27
14-09-04
Philips
NC3
No picture & garbled sound.
Channel change switch S300.
14-09-04
page:
1
2
FB
-
Links
-
Info / Contacts
-
Forum
-
Last SM download : JBL hfe jbl lx90 technical manual en