HitachiNP9ADead - Int dead.DJs14-09-04
HitachiNP9ALine - pulling on verticals.CRT conductive earthing , C983 , C907 , IC980.14-09-04

HitachiNP9AStandby - going into standby at switch on.Check C919 if its a 22u f change it to a 220u f.14-09-04
HitachiNP9AStandby - going into standby int.4.43Mhz crystal X1401. on memory PCB PC895.14-09-04
HitachiNP9AStandby - stuck in standby mode.Change C919 to 220u F , replace C906/918 , drys on T901/70314-09-04
HitachiNP9ATripping.Q905 ( 2SA673 ) o/c.14-09-04
HitachiNP9AWidth - reduced.R756 o/c.14-09-04