MakeModelProblemSolutionDate
Found: 9
SamsungCI3373Z SCT11B/DService mode accessStby/P.STD/HELP/SLEEP/POWER ON. Controls VOL +/- CHANNEL +/- EXIT with Status,{all on r/c} 14-09-04
SamsungCI5373 SCT11BTrippingLOPTx arcing - when replaced field coll; HIC301 VPG101 hybrid chip14-09-04

SamsungSCT11Bdead, fuse blownreplace C803 2n2 800V (2303-000163 or A1102-0331), DZ801 R2KN (0403-000691), IC801 (AA13-20004P), HC801 (AA13-20004M). Note: HC801 and IC801 must be "C" version!14-09-04
SamsungSCT11B CI5079Tframe collapseIC201 MS2309BSP faulty, no drive from pin 18 (1204000431)14-09-04
SamsungSCT11B CI5079Tframe collapseR410 o/c14-09-04
SamsungSCT11B CI5079Tframe jitterreplace HC301 (AA13-20002W)14-09-04
SamsungSCT11B CI5373Tdark pic at switch on, Ok after 10 minLOPTx (AA26-30001Y)14-09-04
SamsungSCT11B CI5373Treduced frame and no video/soundreplace EEPROM IC902 (B4000-0135)14-09-04
SamsungSCT11B/D CI3373 CI5079Dead with DZ801 or IC801 s/cIf signs of overheating round faulty components - psu produces excess HT in st/by; In st/by 125v HT should rise to 140v but does rise to 180v in some sets. Replace DZ801 with pt no 0403-000691; IC801 replace with AA13-20004P; HC801 replace with AA13-20004M & if still excessive Ht change C852 for 2301-00011114-09-04