Make | Model | Problem | Solution | Date |
| | | |
Found: 148
|
Philips | CP110 | "F1" displayed & Field collapse | Dry joint 12v reg IC7675 | 14-09-04 |
Philips | CP110 | "MEMORY LOSS" of one or two arbitrary programmes | Disconnect pin 34 of IC7840 from the +6 Volt.
Add diode 1N4148 (4822 130 30621) between +6 Volt and pin 34 of IC7840 (with cathode to point 34 of IC7840).
Add serie circuit of resistor 10 kOhm and capacitor 100 uF/10Volt (4822 124 40184) between +6 Vo | 14-09-04 |
Philips | CP110 | 1 mm curl in vertical lines | Capacitance of capacitor C2633 100 uF (4822 124 41584) has decreased (dried). Capacitor C2670 22 uF (4822 124 22257) hot. | 14-09-04 |
Philips | CP110 | 140 volt rail collapses after 5 minutes. | Replace standby switch transistor, T7739 - BC548 (4822 130 40938).
| 14-09-04 |
Philips | CP110 | 140v RAIL LOW ( 60-70v ) | C2661 2200uF OC USE Philips PART ONLY | 14-09-04 |
Philips | CP110 | 3 Page layout with faults - Pic cover June 93 | For more faults see also CP90 most of chassis is the same. | 14-09-04 |
Philips | CP110 | At times no contrast. | Replace T7415 (BC556; 4822 130 40989).
| 14-09-04 |
Philips | CP110 | Blank raster with "E" in display | micro s/c to chassis | 14-09-04 |
Philips | CP110 | Blank screen - gives blue screen with fb lines when A1 advanced | Tr7405 BF423 on crt base s/c | 14-09-04 |
Philips | CP110 | BOTTOM OF RASTER MISSING | R3572 O/C 1R5 | 14-09-04 |
|
Philips | CP110 | Brightness varying. | Check/replace D6401 (1N4148: 4822 130 33939) on CRT base PCB.
| 14-09-04 |
Philips | CP110 | BUT11AF gets stuck in stand-by mode; BUT11AF gets hot. | Check the value of resistor R3659 (100 Ohm).
The fault occurs when the resistor is open or when the value is increased. | 14-09-04 |
Philips | CP110 | Chan display reverts to"E" | Micro 7840 faulty | 14-09-04 |
Philips | CP110 | CHANNEL DISPLAY GOES TO " E " | MICRO 7840 | 14-09-04 |
Philips | CP110 | Continuous page header display in subtitle | Change text IC to type MAB8461P/W196 part No4822 209 62479 | 14-09-04 |
Philips | CP110 | Control micro processors | A production change has been introduced adding a shield to the control micro processor to prevent the processor being influenced by external fields. Replacements will be supplied as a kit comprising the processor, shield and fitting instruction.
The sh | 14-09-04 |
Philips | CP110 | Corrugated verticals | C2670, 2621 22µ 250v | 14-09-04 |
Philips | CP110 | Corrugated verticals | C2633 100µ 25v | 14-09-04 |
Philips | CP110 | Dead | BUT11AF , TEA1039 , Bridge rec diodes s/c R3659 ( 100ohm ) , R3658 ( 120R ) C2661 upgrade to ( 2 , 200uF ) & CNX62 | 14-09-04 |
Philips | CP110 | Dead | "F1" SHOWING IN DISPLAY 1653 T1A6 WICKMAN FUSE OPEN | 14-09-04 |
Philips | CP110 | Dead | C2162 0.47MFD ( NEAR C2611 ) | 14-09-04 |
Philips | CP110 | Dead | 1.6A fuse o/c; BUT11AF s/c; mains rect s/c; also replaced CNX62 as precaution. Still no ht - C2656 150µ cause | 14-09-04 |
Philips | CP110 | Dead - chopper tr may be s/c | C2656 150µ 385v o/c, D6672 BYD33D in 32v supply leaky | 14-09-04 |
Philips | CP110 | Dead - fuse intact | Has high drive amplitude briefly at Chopper Tr at sw on - BUT11 chopper Tr o/c b-e | 14-09-04 |
Philips | CP110 | Dead - fuse ok 300v on collector BUT11. | BUT11 o/c base to emitter. | 14-09-04 |
Philips | CP110 | Dead - mains fuse shattered | Check mains bridge rects & 150µ 385v mains smoother for shorts | 14-09-04 |
Philips | CP110 | Dead - no st/by led | 22R safety res 3655 o/c | 14-09-04 |
Philips | CP110 | Dead - tripping chan light pulsing | loptx shorted turns 1-17 | 14-09-04 |
Philips | CP110 | Dead - volts o/p from bridge rect low at 190v | C2656 150µ low cap | 14-09-04 |
Philips | CP110 | DEAD , 300v AT BUT11AF COLL. LOW START VOLTS AT PIN | C2656 OC. | 14-09-04 |