MakeModelProblemSolutionDate
Found: 4551
PhilipsL9H.1ACorrection to service Manual of L9H.1A, L9H.2A, L9H.1E, L9H.2EIn the chassis manual, the service code of the so called "set-up" remote control type RG4172BK (also named T374AH) was not mentioned. The service code is 3135 017 0264114-09-04
PhilipsL9H.1ECorrection to service Manual of L9H.1A, L9H.2A, L9H.1E, L9H.2EIn the chassis manual, the service code of the so called "set-up" remote control type RG4172BK (also named T374AH) was not mentioned. The service code is 3135 017 0264114-09-04

PhilipsL9H.1EOhm/Watt external bathroom speakerOhm/Watt external bathroom speaker ================================== ITV sets with above mentioned chassis are equiped with an external loudspeaker connection. To this connection a bathroom speaker can be connected. If an external loudspeaker is con14-09-04
PhilipsL9H.1EOhm/Watt external bathroom speakerOhm/Watt external bathroom speaker ================================== ITV sets with above mentioned chassis are equiped with an external loudspeaker connection. To this connection a bathroom speaker can be connected. If an external loudspeaker is con14-09-04
PhilipsL9H.1ESet does not work.Replace the EPS panel or replace the diode itemCR2 on the EPS panel by type ER302-0141. Service code diode, type ER302-0141, is 9965 000 06628. Remarks: The EPS panel is a non repairable item. Only for this case, diode with item CR2 is supplied. In14-09-04
PhilipsL9H.1E AAComPair/SearchmanIn the service manuals of above mentioned Chassis on page 14 paragraph 5.7 the ComPair tool is explained. However the ComPair/Searchman user software is not available.14-09-04
PhilipsL9H.1E AACorrection to service manual L9H1.E AAIn the parts list of the service manual only the service code of the complete Clock Panel is mentioned. Below also the service codes of the separate components are listed. 1072 3119 108 51881 Clock panel complete (large LED's) DP1 4822 265 30734 Co14-09-04
PhilipsL9H.2ACorrection to service Manual of L9H.1A, L9H.2A, L9H.1E, L9H.2EIn the chassis manual, the service code of the so called "set-up" remote control type RG4172BK (also named T374AH) was not mentioned. The service code is 3135 017 0264114-09-04
PhilipsL9H.2E"welcome message" doesn't come up at start up.When the set is switched off via the mains switch and is switched on again after more than 5 minutes, the "welcome message" doesn't come up at start up. Put the set into the SDM mode. Select the option AS (Auto start-up). Change the option content fr14-09-04
PhilipsL9H.2ECorrection to service Manual of L9H.1A, L9H.2A, L9H.1E, L9H.2EIn the chassis manual, the service code of the so called "set-up" remote control type RG4172BK (also named T374AH) was not mentioned. The service code is 3135 017 0264114-09-04
PhilipsL9H.2EOhm/Watt external bathroom speakerOhm/Watt external bathroom speaker ================================== ITV sets with above mentioned chassis are equiped with an external loudspeaker connection. To this connection a bathroom speaker can be connected. If an external loudspeaker is con14-09-04
PhilipsL9H.2EService code of the FM-Radio tuner.In the partslist of the Radio-SP/LS-Vbatt panel of the Chassis Manual L9H.2E, the service code of the FM-Radio tuner item 1901 was not indicated. The service code is 9352 632 7011214-09-04
PhilipsL9H.2ESet does not work.Replace the EPS panel or replace the diode itemCR2 on the EPS panel by type ER302-0141. Service code diode, type ER302-0141, is 9965 000 06628. Remarks: The EPS panel is a non repairable item. Only for this case, diode with item CR2 is supplied. In14-09-04
PhilipsL9H.2ESets do not work properly with CANAL+ decoder.Sets do not work properly with CANAL+ decoder connected to the scart connector(sound and picture are not de-scrambled). Replace the micro-computer item 7600 with an execution with software version 1.5 or higher. The codenumbers for the micro-computers14-09-04
PhilipsL9H.2E AAComPair/SearchmanIn the service manuals of above mentioned Chassis on page 14 paragraph 5.7 the ComPair tool is explained. However the ComPair/Searchman user software is not available.14-09-04
PhilipsL9H.2E AACorrection to Service Manual L9H.2E AAIn the parts list of the service manual only the service code of the complete Clock Panel is mentioned. Below also the service codes of the separate components are listed. 1072 3119 108 51861 Clock panel complete (Small LED's) DP1 4822 265 30734 Co14-09-04
PhilipsLO1.1E/2EService mode enteringenter 062596 then OSD/STATUS button on handset. Arrow up/down to access req adj, arrow right/left to adjust, standby to store. Make sure chan 6 is tuned to a chan or test pattern as set ends up on chan 6.14-09-04
PhilipsMD 2.21 AA 28PT7303After replacing LOPTx set starts up with brief EHT then reverts to st/byFET on same heatsink as BU2520 is S/C 14-09-04
PhilipsMD1.0ABad focus or focus varies in a new set or after CRT replacementPossible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla14-09-04
PhilipsMD1.0AClock inaccurateCheck and replace if necessary: item 1650 an improved 8MHz crystal (4822 242 10364). REMARKS :This solution is implemented in production from week 9727 onwards.14-09-04
PhilipsMD1.0AEasy way to check the Power SupplyEasy way to check the Power Supply---------------------------------- The MC44603 can be checked for basic operation without the set being connected to the Mains supply. Method: 1) Discharge the 300V smoothing Capacitor. 2) Connect a BYD33D Diode to p14-09-04
PhilipsMD1.0AErrata MD1.0A AA Supplement (4822 727 21506)Errata MD1.0A AA Supplement (4822 727 21506) There is an error in diagram C on page 6. Position number 3376 (location L 10) should be 3380.14-09-04

PhilipsMD1.0AMicroprocessor Survey MD1.0AMicroprocessor Survey MD1.0A SOFTWARE FAMILY...VERSION...IDENT...SERVICE CODE...LAST VERSION Pal/Multi 4x3 4.4 3315 4822 900 14885 V4.6 (4.5..3353 4822 900 10968) (4.6...3448 4822 900 11073) NTSC Korea 4x3 14-09-04
PhilipsMD1.0ANo rasterCheck and replace if necessary: Item Description (New) Order number 2137 220nF 25V 20% 4822 126 13061 on the small signal panel. REMARKS :IRIS symptom code: 131614-09-04
PhilipsMD1.0ANo synchronisation on AV (input) signalCheck and replace if necessary: Item Description (New) Order number 2115 220nF 25V 20% 4822 126 13061 on the small signal panel. REMARKS :IRIS symptom code: F36114-09-04
PhilipsMD1.0ANo synchronisation with OFF-AIR (arial) pictureCheck and replace if necessary: Item Description (New) Order number 2122 220nF 25V 20% 4822 126 13061 on the small signal panel. REMARKS :IRIS symptom code: F36114-09-04
PhilipsMD1.0AREPAIR KITS AVAILABLEREPAIR KITS AVAILABLE In order to easily repair line and SMPS problems, two universal repairs kits are available for the following chassis: CHASSIS REGION MD1.0A 4:3 & 16:9 Asia Pacific & Latam MD1.1E 4:3 & 16:9 Eur14-09-04
PhilipsMD1.1Bad focus or focus varies in a new set or after CRT replacementPossible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla14-09-04
PhilipsMD1.1Dead with faint tripping heard with LED flashing red/orange/green every 2 secsI?C bus fault - SDA line held low; caused by the tuner14-09-04
PhilipsMD1.1AColour spot during switch offReplace item R3392 on the CRT panel by a jumper. REMARKS :This modification was introduced in production from week 9727 onwards.14-09-04