Text preview for : tv05_0081_white_vertical_bar1_677.pdf part of Philips tv05 0081 white vertical bar1 677 Philips LCD TV (and TPV schematics) LC4.7E aa tv05_0081_white_vertical_bar1_677.pdf



Back to : tv05_0081_white_vertical_ | Home

Connected Displays Symptom Cure / Service Info Attachment




Reference Number: TV-05/0081
1. Rework Instructions "White vertical bar on screen"
1.1. Symptom

White bar in the middle of plasma screen:




1.2. Rework instruction :

1. Cut the rib on the shielding frame 42" (3104 328 32641) as shown on figures below:




Position of the rib
inside shielding



BEFORE AFTER




Rib too large, can create short
circuit or is damaging the
ABSUS board (see picture
Cut rib w. pliers
below) from the plasma panel.

Document version: 1.0 Page: 1/2 Date: 2005-06-23
Connected Displays Symptom Cure / Service Info Attachment




2. Verify if the ABSUS board of the SDI panel shows any damaged components at the location of the rib.




Document version: 1.0 Page: 2/2 Date: 2005-06-23