Text preview for : sc1_note.pdf part of panasonic sc1 note panasonic LCD PT-50LC13 PT-50LC13 SVC sc1_note.pdf



Back to : sc1_note.pdf | Home

1. Important safety notice 3. Parts marked "PT" are not used in any models included
Components identified by the sign have special in this service model.
characteristics important for safety. When replacing any
of these components. Use only the specified parts.
C6011 C6011 R6097
Example: 100P PT PT
2. Do not use the part number shown on this drawing for PT
ordering.
The correct part number and part value is shown in the
parts list, and may be slightly different or amended since 4. Jumper wires are used for WA10, WA5 etc and these are
this drawing was prepared. not supplied as replacement parts.

3. Use only original replacement parts: Circuit Board Layout Note
To maintain original function and reliability of repaired Circuit Board Layout shows components installed for
units, use only original replacement parts which are listed various models.
with their part numbers in the parts list section of the For proper parts content for the model you are servicing,
service manual. please refer to the schematic diagram and parts list.

4. Parts different in shape or size may be used. NOTE:
However, only interchangeable parts will be supplied as Circuit Board Layout includes components which are not
service replacement parts. used.

5. Test point information
: Test point with a jumper wire across a hole in P.C.B.
: Test point with no test pin.

Schematic Diagram Notes
1. Indication for Zener Voltage of Zener Diodes
The Zener Voltage of Zener Diodes are indicated as such
on Schematic Diagrams.

Example:
(6.2V)......Zener Voltage

2. How to identify Connectors
Each connector is labeled with a Connector No. and Pin
No. Indicating what it is connected to,
in other words, its counter part.
Use the interconnection schematic diagram to find the
connection between associated connectors.


Example:
The connections between C.B.A.s are shown below.

Ref. No. of the connection parts such as lead cable,
flexible cable which is supplied as a replacement parts.
The Number of pins of the Connector.
POWER SUPPLY
C.B.A. MAIN C.B.A.
P1503 P3004
244 (10 Pins)

Connector No.
on Main C.B.A.




PT-50LC13