Text preview for : SNL2001_02.pdf part of Philips SNL2001 02 Philips Symptom Cure 2-2002 References SNL2001_02.pdf



Back to : SNL2001_02.pdf | Home

For internal use only PHILIPS

ISSUE SNL2001.02 (01-05-16)
Published by:
Service Department Audio

BUSINESS CREATION UNIT AUDIO

SERVICE NEWSLETTER
02.01 TYPENUMBER(S): ACT7585

INFORMATION : Correction to Service Manual
CD-drive DA23LN (3103 309 05320) has been used instead of
DA23L (3103 309 05340). The new CD-drive requires the following
modification for proper detection of the drive version:
Add 3418 4822 051 30008 Chip Jumper 0603
Delete 3419

REMARKS :


02.02 TYPENUMBER(S): ACT7585

INFORMATION : Correction to the Service Manual, Partslist
Resistor 3869 should be 47 (4822 051 30479).

REMARKS :


02.03 TYPENUMBER(S): AZ1018

INFORMATION : In course of production, resistor 3452 has been changed from 2.7k
to 4.7k (4822 051 30472) to improve "LCD leakage".

REMARKS :


02.04 TYPENUMBER(S): AZ1110, AZ1111, AZ1112, AZ1113, AZ1114, AZ1116, AZ1117,
AZ1118, AZ1119, AZ8084, AZ8085, AZ8086, AZ8087

SYMPTOM : IRIS CODE 2 1 1 X
Set doesn't work with some specific batteries due to inproper battery
contact.

CURE : The guiding rib in the battery compartment has been modified.

REMARKS : Modified parts are used in production with production code
KZ010049136XXX from week 0049 onwards.




Service Newsletter 2001