TP100AW Series
DESCRIPTION 100W 1.5KVAC Isolation Wide Input AC/DC Converters

The rated output power of TP100AW converters is 100W with wide input voltage range, for both AC input and
DC input application. High reliability, precision, large power density, ultra-small size, stable output voltage and
etc, with 1500V isolation voltage, short circuit, overload, internal thermal protection, Widely used in
telecommunications, industrial control, instrument, data acquisition, signal control and other electronic systems.



FEATURES
Universal input voltage range Both for AC and DC input voltage Wide input voltage:2:1 and 4:1
RoHS compliant Operating temperature: -25 to 70 /
Short circuit protection / /

SELECTION GUIDE
Input Voltage Output
Efficiency
Part Number Rated Range values (Typ. ) Capacitive ability(uF)
VoltageVDC) CurrentA %
VAC)
TP100AW 220S12 220(2:1) 165-265 12 8.33 85 2200
TP100AW 220S15 220(2:1) 165-265 15 6.66 84 2200
TP100AW 220S24 220(2:1) 165-265 24 4.17 83 1000
TP100AW 220S48 220(2:1) 165-265 48 2.08 83 470
TP100AW 220S12W 220(4:1) 85-265 12 8.33 85 2200
TP100AW 220S15W 220(4:1) 85-265 15 6.66 84 2200
TP100AW 220S24W 220(4:1) 85-265 24 4.17 83 1000
TP100AW 220S48W 220(4:1) 85-265 48 2.08 83 470
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.



GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation voltage Input / Output 1500 VAC
Isolation voltage Input / case 1500 VAC
Isolation voltage Output / case 500 VAC
5
MTBF 3×10

Case material Six-side metal shield
Safety standard CSA/NRTL/IEC/EN 60950-1,

INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Startup voltage 220VAC In module(165V-265V) 165 220 265 VAC
Startup voltage 220VAC In module(85V-265V) 85 220 265 VAC
Start rising time Non-capacitive load 20 ms
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage accuracy ±1 %
Voltage regulation ±0.2 %
Load regulation ±0.5 %

Dynamic Response (overshoot/recovery time) ±4%Vo/400us

Ripple and noise Vo48Vdc200Others100
Short-circuit protection Auto-recovery


www.gztoppower.com TEL:0086-20-62162688 Email:[email protected] page 1 of 2
TP100AW Series
ENVIRONMENT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Operating temperature industrial-class -40 +70
Maximum case temperature industrial-class -25 +85
Storage temperature Industry-class -40 +105
Relative humidity No condensation 5 90 RH(%
Temperature coefficient ±0.02 %/


Case temperature shall not exceed the maximum case temperature


MECHANICAL DIMENSIONS PIN CONNECTIONS

DIP Package

Pin Single output

1 NP
2 L
3 N
4 NP
5 FG
6 NP
7 NP
8 NP
9 NP
10 NC
11 -Vo
12 -Vo
13 +Vo
14 +Vo




unit: mm tolerance of PIN diameter±0.10MM Unmarked tolerances :±0.50MM



MODEL SELECTION
TP 100 A W 220 S 05 W

W:4:1 Wide voltage input range
Main (auxiliary) output voltage
S:single output, D:Dual output
Rated input voltage
Package type
AC-DC
Rated output power
Brand name



www.gztoppower.com TEL:0086-20-62162688 Email:[email protected] page 2 of 2