Text preview for : 53xe_sch.pdf part of . Various 53xe sch . Various SM scena Symetrix 53xe_sch.pdf



Back to : 53xe_sch.pdf | Home

6 5 4 3 2 1
REVISION RECORD
REV REVISIONS DONE OR ECO NUMBER: DATE:

B.00 Delete "pass thru" connection on J4 7/18/97




D D
THIS GENERIC I/O USED ON PRODUCTS WITH A NEED FOR EXTERNAL SIDE CHAIN




J6
1




7

8
6
2
3

4
5
J1 XLR-MALE
J2
2 2
1 1
3
3
4 4

C C5 C1
470pF
C2
470pF
C6
470pF
C7
470pF C
470pF




1 J5
H1
J3
MH156

MOUNTING HOLE




NOTE: Input ground and output ground
are separate. They become common on
B the main PCB. B
J4




C3 C4
470pF 470pF




COMPANY:
SYMETRIX INC.
14926 35th Avenue West
A A
Lynnwood, WA 98037-2303 USA
TITLE: REV:
DRAWN:
R
DATED: GENERIC I/O - WITH SIDE CHAIN A.00
B 2/5/97
DRAWING NO:
RELEASED: DATED:
GIO-3B00 SHEET: 1 OF 1