Text preview for : prima_42d8_164.pdf part of PRIMA prima 42d8 164 . Rare and Ancient Equipment PRIMA Plasma prima_42d8_164.pdf



Back to : prima_42d8_164.pdf | Home

COLOR TELEVISION




PS-42D8 B
PS-42D8 S
PH-42D8
CONTENT


Safety instructions...................................................................................... 1
Method of Debugging ................................................................................. 4
Method of software upgrading ...................................................................... 5
Briefing on the operation principle of the plasma TV series PS and PH ................ 7
Wiring diagram.......................................................................................... 15
Distribution of the Circuit Board of Different Screens and their Functions ............. 18
PCB parts and number ............................................................................... 19
Diagnosis for Plasma Screen of PS and PH ................................................... 20
Troubleshooting guide................................................................................ 23
Schematic diagram.........................................................................................
28
Exploded views......................................................................................... 43
Note: This maintenance manual is intended only for the reference of the maintenance people.
Please pay attention to the following points before carrying out the maintenance work.




Safety Instructions

Please read the "Points for attention for the Maintenance & Repair of PDP"and "Criterion for
Identifying the Defects on Screen" as below, before inspecting and adjusting the TV set.

1. "Points for attention for the Maintenance & Repair of PDP"
To avoid possible danger, damage or jeopardy to health and to prevent PDP screen from new
damage, the maintenance people must read the following carefully. If they ignore the following
warnings, there will be deathful risks:
1.1 Screens vary from one model to another and therefore not interchangeable. Be sure to use the
same type of screen in the replacement.
1.2 The operation voltage is approximately 350v for PDP module (including screen, driving circuit,
logic circuit and power module). If you want to conduct maintenance work on PDP module when
the set is in normal operation or just after the power is off, you must take proper measures to
avoid electric shock and never have direct contact or touch with the circuitry of the working
module or metal parts. That's because within a short time relatively high voltage still remains on
the capacitor of the driving part even after the power is off. Make sure to begin relevant
maintenance operation at least one minute after the power is off.
1.3 Don't apply on the module any power supply that is higher than the specification.If the power supply
used deviates from the value given in the specification, there might be a possibility of leading to fire or
damage to the module.
1.4 Never have operation or mounting work under unsuitable environment such as areas in the
vicinity of water