Text preview for : TP05DB.pdf part of TOPPOWER TP05DB TOPPOWER can produce: 0.1W-400W DC-DC converters,1W-30W AC-DC converters,(SIP/DIP/SMD) TOPPOWER quality : ISO9001:2015, IATF16949:2016 accept OEM orders.



Back to : TP05DB.pdf | Home

TP05DB Series
DESCRIPTION 5W 1.5KVDC Isolated Wide Voltage Input DC/DC Converters
The rated output power of TP05DB converters is 5W,the outline dimensions is "25.4*25.4*11.2", 2:1
and 4:1 wide input voltage range, the voltage range is 4.5V-9V9V-18V,18V-36V,36V-72V,9V-36V
and 18V-72VDC.The accuracy of the converter can reach ±1%,it can be widely used in
telecommunications, railway transportation, instrument and etc.
FEATURES
5W output power 2:1 and 4:1 wide input Voltage range Over load protection
25.4mm*25.4mm*11.2mm standard package Fixed switching frequency Operating temperature: -40to 85
Metal shell package RoHS compliant 1.5KVDC isolation

SELECTION GUIDE
Input Vlotage Output Maxium Capacitive
Efficiency(Typ)




R
Part Number voltageVDC) Load
VoltageVDC) CurrentA % u F)
Rated Range values
TP05DB05S05 5(2:1) 4.5-9 5 1 74 1500




E
TP05DB05S12 5(2:1) 4.5-9 12 0.42 75 660
TP05DB05D12 5(2:1) 4.5-9 ±12 ±0.21 78 ±140
TP05DB05D15 5(2:1) 4.5-9 ±15 ±0.17 75 ±47
TP05DB12S03 12(2:1) 9-18 3.3 1 73 2200
TP05DB12S05 12(2:1) 9-18 5 1 74 1500




W
TP05DB12S12 12(2:1) 9-18 12 0.42 75 660
TP05DB12S15 12(2:1) 9-18 15 0.33 75 470
TP05DB12D05 12(2:1) 9-18 ±5 ±0.5 76 ±850




O
TP05DB12D12 12(2:1) 9-18 ±12 ±0.21 78 ±140
TP05DB12D15 12(2:1) 9-18 ±15 ±0.17 79 ±47




P
TP05DB24S03 24(2:1) 18-36 3.3 1 74 2200
TP05DB24S05 24(2:1) 18-36 5 1 76 1500
TP05DB24S12 24(2:1) 18-36 12 0.42 76 660




P
TP05DB24S15 24(2:1) 18-36 15 0.33 76 470
TP05DB24S24 24(2:1) 18-36 24 0.21 79 470
TP05DB24D05 24(2:1) 18-36 ±5 ±0.5 78 ±850




O
TP05DB24D12 24(2:1) 18-36 ±12 ±0.21 79 ±140
TP05DB24D15 24(2:1) 18-36 ±15 ±0.17 79 ±47
TP05DB48S03 48(2:1) 36-72 3.3 1 74 2200




T
TP05DB48S05 48(2:1) 36-72 5 1 76 1500
TP05DB48S12 48(2:1) 36-72 12 0.42 78 660
TP05DB48S15 48(2:1) 36-72 15 0.33 78 470
TP05DB48D05 48(2:1) 36-72 ±5 ±0.5 79 ±850
TP05DB48D12 48(2:1) 36-72 ±12 ±0.21 79 ±140
TP05DB48D15 48(2:1) 36-72 ±15 ±0.17 80 ±47
TP05DB24S05W 24(4:1) 9-36 5 1 75 1500
TP05DB24S12W 24(4:1) 9-36 12 0.42 75 660
TP05DB24S15W 24(4:1) 9-36 15 0.33 75 470
TP05DB24D05W 24(4:1) 9-36 ±5 ±0.5 77 ±850
TP05DB24D12W 24(4:1) 9-36 ±12 ±0.21 78 ±140
TP05DB24D15W 24(4:1) 9-36 ±15 ±0.17 78 ±47
TP05DB48S05W 48(4:1) 18-72 5 1 75 1500
TP05DB48S12W 48(4:1) 18-72 12 0.42 77 660
TP05DB48S15W 48(4:1) 18-72 15 0.33 77 470
TP05DB48D05W 48(4:1) 18-72 ±5 ±0.5 78 ±850
TP05DB48D12W 48(4:1) 18-72 ±12 ±0.21 78 ±140
TP05DB48D15W 48(4:1) 18-72 ±15 ±0.17 79 ±47

www.gztoppower.com TEL0086-20-62162688 [email protected] page 1 of 4
TP05DB Series
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified


GENERAL CHARACTERISTICS
parameter Test conditions Min Typ Max Units
Isolation voltage Input to Output 500 1500 VDC
Isolation resistance Input to Output 100M ohm
Seismic 10~55Hz 5 G
MTBF MIL-HDBK-217F2 5 x 105 hrs
Over-current protection mode Full input range Auto recovery
Cooling Free air convection




R
Case material Metal case

INPUT CHARACTERISTICS




E
parameter Test conditions Min Typ Max Units
Startup voltage 5V Input module(4.5V -9V) 4.5 5 9 VDC
Startup voltage 12V Input module(9V -18V) 8.8 9 9.3 VDC
Startup voltage 24V Input module(18V-36V) 18 VDC




W
Startup voltage 48V Input module(36V-72V ) 36 VDC
Startup voltage 24V Input module(9V -36V) 8.8 9 9.3 VDC
Startup voltage 48V Input module(18V-72V) 18 VDC




O
Start rising time Input rising time from 5%-100% 20 ms

OUTPUT CHARACTERISTICS
parameter Test conditions Min Typ Max Units




P
Voltage accuracy Io=0.1...1.0 x Ionom Vi=Vi rated ±1 %
Line regulation ViminViVimax ±0.2 %




P
Io=0.1...1.0 x Ionom
Load regulation ±0.5 %
Vimin ViVimax

Main Load and auxiliary load differ 25%,the auxiliary




O
Auxiliary voltage accuracy circuit of the load with at least 25%, the main circuit ±3 %
with full load
Ripple and noise 20MHz bandwidth ±1 %




T
Over-current protection ViminViVimax 120 %
Transient recovery time 25% load change ±5 %
Transient overshoot range 25% load change 400 us
Switch frequency ViminViVimax 300 KHz

ENVIRONMENT CHARACTERISTICS
parameter Test conditions Min Typ Max Units
Storage Humidity Non condensing 5 +95 %
Operating Temperature Power derating (above 71 -40 +85
Storage Temperature -55 +125
Max. Case Temperature Operating Temperature curve range 105
Lead Temperature 1.5mm from case for 10 seconds 300
Cooling Free air convection


Case temperature under shall not exceed the maximum case temperature level.




www.gztoppower.com TEL0086-20-62162688 [email protected] page 2 of 4
TP05DB Series
MECHANICAL DIMENSIONS PIN CONNECTIONS

DIP Package
Pin Single output Dual output
5
1 +Vin +Vin
10.16 2 -Vin -Vin
1
25.40 5.08 3 -Vout -Vout
4
2 4 / Com
bottom view 10.16
10.16
5 +Vout +Vout
3 2.54




R
20.32 2.54
25.40




E
11.20




W
>4.00 1.20
1.00


Units: mm




O
Tolerance:±0.2mm

MODEL SELECTION




P
TP 05 D B 24 S 05 W




P
W:4:1 Wide voltage input range
Output voltage

S: single output D: Dual output




O
Input Rated Voltage

Package type




T
DC-DC
Output rated power
Brand name

RECOMMEND CIRCUIT:
Single Output

+vin +V0


+ +
Cin DC-DC Cout
-vin -V0




www.gztoppower.com TEL0086-20-62162688 [email protected] page 3 of 4
TP05DB Series
RECOMMEND CIRCUIT:
Dual Output


+ vin + V0

+
Cout1
+ COM
Cin DC-DC
+
Cout2
-vin -V0




R
Add input capacitance Cin is helpful to improve the electromagnetic compatibility, recommend Cin use 47 uF-100uF of the electrolytic capacitors.
If the module connect to the digital circuits, please add the CoutCout1Cout2.




E
If Cout, Cout1, Cout2 value is too high or lower ESR, it will cause the module instable,
The recommended value of Cout, Cout1, Cout2 should be 100 uF/A, the current here means the output current.




W
USING ATTENTIONS




O
Module will cause irreversible damage when in the state of the input reverse polarity.
Module will cause irreversible damage when in the long-term overload conditions.
Module will cause irreversible damage when out of the maximum input voltage range.




P P
STEMPERATURE DERATING GR




T O
www.gztoppower.com TEL0086-20-62162688 [email protected] page 4 of 4