Text preview for : InfSDUHSI0141 U7246A B SD UHS-I Card Compliance Test Application Release Notes (Version 01.41) c2014 part of



| Home

Agilent U7246A/U7246B SD Card UHS-I Compliance Test
Application Software Release Notes


Agilent U7246A /U7246B Software Version 1.41.0000
Released Date: 16 JUNE 2014
Minimum Infiniium Oscilloscope Baseline Version: 4.60 (9000 and 90000
series)


Modifications:
1. Resolved scope model verification issue.




Page 1 of 8
Agilent U7246A /U7246B Software Version 1.40.0000
Released Date: 1 JUNE 2014
Minimum Infiniium Oscilloscope Baseline Version: 4.60 (9000 and 90000
series)

Modification:

1. Supports for Infiniium Oscilloscope Software version 5.00.




Page 2 of 8
Agilent U7246A Software Version 1.33.0000
Released Date: 9 May 2014
Minimum Infiniium Oscilloscope Baseline Version: 4.20 (9000 and 90000
series)

Enhancements:

1. Added "Trigger Timeout" option in Configure Tab for user to edit the
timeout value.
2. Added Threshold Levels tests (Output High Voltage test, VOH and Output
Low Voltage test, VOL)

Note: This will be the last version to support Infiniium Oscilloscope Baseline
Version 4.20.




Page 3 of 8
Agilent U7246A Software Version 1.32.0000
Released Date: 14 Aug 2013
Minimum Infiniium Oscilloscope Baseline Version: 4.20 (9000 and 90000
series)

Modifications:

1. Fixed Clock Frequency Verification issue.
2. Fixed the histogram issue that disrupts the eye diagram when histogram
source change.
3. Changed the triggering method for Precision Mode Test.
4. Turn off all color setting for signal source.
5. Changed the scaling method for Current Consumption Test.
6. Fixed vertical scaling issue for the tests on CMD Lane.
7. Changed the triggering method for Current Consumption Test.
8. Changed the Timeout value for Current Consumption Test
9. Fixed histogram measurement issue

Enhancements:

3. Added "tdCK" and "tdRF" option in Configure Tab for Output Delay and
Output Hold Time Compensation feature.
4. Added "Maximum Trial" option in Configure Tab to resend command for
Current Consumption Test
5. Made enhancement on Current Consumption Test to avoid "MISSMATCH"
error.
6. Added Support for MSOX90000 Series Oscilloscopes




Page 4 of 8
Agilent U7246A Software Version 1.31.0000
Released Date: 17 November 2011
Minimum Infiniium Oscilloscope Baseline Version: 3.20 (9000 and 90000
series)

Modifications:

1. Change of result display sequence in Rise/Fall Time Relation test.
2. Windows 7 x64 driver for USB Interface of TED Host emulator can be
found at:
C:\ProgramData\Agilent\Infiniium\Apps\SDUHSITest\App\ConsoleA
pps\sd_test_win7_x64\
3. Change of wait time for SD card slot verification.
4. Using probe calibrated value instead of probe default value.



Enhancements:

1. Compatible with Window 7 based Oscilloscope.




Page 5 of 8
Agilent U7246A Software Version 1.30.0000
Released Date: 8 July 2011
Minimum Infiniium Oscilloscope Baseline Version: 2.50 (9000 and 90000
series)

Addition:

1. Added usability of test filter in Setup tab, user can now filter tests
according to Speed Mode and DAT/CMD Lane Configuration.

Modifications:

1. Upgraded to new usb_sdtestapi.dll.
2. Changed the connection diagram in Current Consumption Test.
3. Changed the Test Pattern Size value for Configure option of `Card
Read/Write Start Size for B.O.T' (RC and PM mode).
4. Changed the default value for Configure option of `Current Limit