Text preview for : 5990-4753EN N2792A N2818A 200 MHz and N2793A N2819A 800 MHz Differential Probes- Data Sheet c2014092 part of



| Home

Keysight Technologies
N2792A/N2818A 200 MHz
and N2793A/N2819A 800 MHz
Differential Probes



Data Sheet
Introduction

The Keysight Technologies, Inc. N2792A/93A and N2818A/19A differential probes provide
the superior general-purpose differential signal measurements required for today's high-
speed power measurements, vehicle bus measurements and digital system designs.

The differential probes offer a 10:1 attenuation setting, allowing them to be used for a broad
range of applications. The probes come with various probe tip accessories for use with
small and large components in tight places.

The differential probes have an input resistance of 1 M (for N2792A/N2818A) and 200
k (for N2793A/N2819A) and a low input capacitance of 3.5 pF (for N2792A/N2818A) and
1 pF (for N2793A/N2819A) to minimize circuit loading. Both N2792A and N2793A probe
are compatible with any oscilloscope with 50 BNC inputs. The probe can be powered by
any USB port on a scope or computer, or by an internal battery (1x 9V battery included).
The N2818A and N2819A are compatible with the Keysight Technologies, Inc. AutoProbe
interface where the probe power is supplied by the oscilloscope's probe interface.




2
N2792A/N2818A 200 MHz Differential Probe