Text preview for : 5991-3616EN ENA Series Network Analyzer - Configuration Guide c20140728 [6].pdf part of Agilent 5991-3616EN ENA Series Network Analyzer - Configuration Guide c20140728 [6] Agilent 5991-3616EN ENA Series Network Analyzer - Configuration Guide c20140728 [6].pdf



Back to : 5991-3616EN ENA Series Ne | Home

Keysight E5063A
ENA Series Network Analyzer
100 kHz to 4.5/8.5/18 GHz




Configuration Guide
Ordering Guide

The following steps will guide you through configuring your Keysight Technologies' E5063A.

Standard furnished item
Description Additional Information
Installation guide Contains the information necessary to start up with the E5063A.
CD ROM IO libraries
Power Cable
Calibration of Certification


Step 1. Choose frequency option (must choose one of the three frequency options.)
Description Option No.
Network Analyzer 100 kHz to 4.5 GHz, S-parameter test set, 50 system impedance E5063A-245
Network Analyzer 100 kHz to 8.5 GHz, S-parameter test set, 50 system impedance E5063A-285
Network Analyzer 100 kHz to 18 GHz, S-parameter test set, 50 system impedance E5063A-2H5


Step 2. Choose software option (If not required, go to step 3.)
Description Option No. Requires Not Compatible Additional Information
Time Domain/Test wizard E5063A-011 None None This option is required for time domain analysis or PCB
measurements.




Step 3. Choose storage drive option (mandatory option)
Description Option No. Requires Not Compatible Additional Information
Standard storage drive E5061B-019 None None Option 019 is the only storage drive option for the E5063A.
Must choose this option




Step 4. Add accessory option (If not required, go to step 5.)
Description Option No. Requires Not Compatible Additional Information
Keyboard E5063A-810 None None USB Keyboard for simplifying word inputs.
Mouse E5063A-820 None None USB Mouse for simplifying measurement operation.
Rackmount Kit E5063A-1CM None None Not installable simultaneously with E5063A -1CP.
Front Handle Kit E5063A-1CN None None Not installable simultaneously with E5063A -1CP.
Handle/Rack Mount Kit E5063A-1CP None None Not installable simultaneously with E5063A -1CM or 1CN.




Step 5. Add calibration certificate (If not required, go to step 6.)
Description Option No. Additional Information
ISO 17025 Compliant Calibration E5063A-1A7 ISO 17025 compliant calibration
ANSI Z540 compliant calibration E5063A-A6J ANSI Z540 compliant calibration




2
Step 6. Choose warranty plan
3 year return-to-keysight warranty and service is standard. The extended warranty option is available. Contact your local Keysight office or visit our web site for
more information.

Step 7. Add related products
Description Option No. Requires Not Compatible Additional Information
USB Coaxial Switch, DC to 18 U1810B None None The number of test ports can be expanded up to four by
GHz, SPDT connecting this SPDT switch to the E5063A's port-1 and 2.