Text preview for : Panel_SHARP_LM130SS1T611_0_[DS].pdf part of . Various Panel SHARP LM130SS1T611 0 [DS] . Various LCD Panels Panel_SHARP_LM130SS1T611_0_[DS].pdf



Back to : Panel_SHARP_LM130SS1T611_ | Home

Global LCD Panel Exchange Center www.panelook.com




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
Global LCD Panel Exchange Center www.panelook.com



DOC.First issue MAR.1.2000
RECORDS OF REVISION Model No. LM130SS1T611
Spec. No. LC00303
DATE REF.PAGE REVISED SUMMARY CHECK
PARAGRAPH AND
DRAWING No. NO. APPROVAL




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
Global LCD Panel Exchange Center www.panelook.com

SPEC No. MODEL No. PAGE
LC00303 LM130 SS1 T611 1


[Precautions]
1) Industrial (Mechanical) design of the product in which this LCD module will be incorporated must
be made so that the viewing angle characteristics of the LCD may be optimized.
This module's viewing angle is illustrated in Fig.1.
y MIN. < viewing angle < y MAX.
(For the specific values of y MIN., and y MAX., refer to the Table 9.)
Please consider the optimum viewing conditions according to the purpose when installing the module.



Viewing direction + y
y=0 . (Normal line)


y




Panel surface



Fig.1 Definition of viewing angle


2) This module should be installed using mounting holes of metal bezel.
When installing the module, pay attention and handle carefully not to allow any undue stress such
as twist or bend.
3) Since the front polarizer is easily damaged. Please pay attention not to scratch on its face.
It is recommended to use a transparent acrylic resin board or other type of protective panel on the
surface of the LCD module to protect the polarizer, LCD panel, etc..
4) If the surface of the LCD panel is required to be cleaned, wipe it swiftly with cotton or other soft
cloth. If it is not still clear completely, blow on and wipe it.
5) Water droplets, etc. must be wiped off immediately since they may cause color changes, staining, etc.,
if it remained for a long time.
6) Since LCD is made of glass substrate, dropping the module or banging it against hard objects maycause
cracking or fragmentation.




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
Global LCD Panel Exchange Center www.panelook.com

SPEC No. MODEL No. PAGE
LC00303 LM130 SS1 T611 2


7) Since CMOS LSIs are equipped in this module, following countermeasures must be taken to avoid
electrostatics charge.
1. Operator
Electrostatic shielding clothes shall be had because it is feared that the static electricity is
electrified to human body in case that operator have a insulating garment.
2. Equipment
There is a possibility that the static electricity is charged to equipment which have a function of peeling
or mechanism of friction(EX: Conveyer, soldering iron, working table), so the countermeasure
(electrostatic earth:1 108 ) should be made.
3. Floor
Floor is a important part to leak static electricity which is generated from human body or equipment.
There is a possibility that the static electricity is charged to them without leakage in case of insulating
floor, so the countermeasure(electrostatic earth:1 108 ) should be made.
4. Humidity
Humidity of working room may lower electrostatics generating material's resistance and have something
to prevent electrifying. So, humidity should be kept over 50% because humidity less than 50 % may
increase material's electrostatic earth resistance and it become easy to electrify.
5. Transportation/storage
The measure should be made for storage materials because there is a possibility that the static electricity,
which electrify to human body or storage materials like container by friction or peeling, cause the
dielectric charge.
6. Others
The laminator is attached on the surface of LCD module to prevent from scratches, fouling and dust.
It should be peeled off unhurriedly with using static eliminator.
And also, static eliminator should be installed to prevent LCD module from electrifying at assembling
line.
8) Don't use any materials which emit gas from epoxy resin(amines' hardener) and silicon adhesive
agent (dealcohol or deoxym) to prevent change polarizer color owing to gas.
9) Since leakage current, which may be caused by routing of CCFT cables, etc., may affect the brightness
of display, the inverter has to be designed taking the leakage current into consideration. Thorough
evaluation of the LCD module/inverter built into its host equipment shall be conducted, therefore,
to ensure the specified brightness.
10) Avoid to expose the module to the direct sun-light, strong ultraviolet light, etc. for a long time.
11) If stored at temperatures under specified storage temperature, the LC may freeze and be deteriorated.
If storage temperature exceed the specified rating, the molecular orientation of the LC may change to
that of a liquid, and they may not revert to their original state. Therefore, the module should be always
stored at normal room temperature.



One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
Global LCD Panel Exchange Center www.panelook.com

SPEC No. MODEL No. PAGE
LC00303 LM130 SS1 T611 3


12) Disassembling the LCD module can cause permanent damage and should be strictly avoided.
Procedure insert mating connector
When the mating connector is inserted, it should be parallel to the used connector of LCD module and it
should be inserted on horizontal firm base. When the mating connector is attempted to be fixed to LCD
connector, it should be inserted properly in order not to create a gap as shown "A".
Please insert the connector as both edge is placed to the connect position of LCD connector.
1)Method of correct insert
Stress is dispersed




Base (horizontal film base) is required




2)Method of wrong insert
Stress is dispersed




Base (horizontal film base) is required



14) This specification describes display quality in case of no gray scale. Since display quality can be
affected by gray scale methods, display quality shall be carefully evaluated for the usability of LCD
module in case gray scale is displayed on the LCD module.
15) The module should be driven according to the specified ratings to avoid permanent damage.
DC voltage drive leads to rapid deterioration of LC, so ensure that the drive is alternating waveform by
continuous application of the signal M. Especially the power ON/OFF sequence shown on Page 26
should be kept to avoid latch-up of drive LSI and application of DC voltage to LCD panel
16) It is a characteristic of LCD to maintain the displaying pattern when the pattern is applied for a long
time.(Image retention) To prevent image retention, please do not apply the fixed pattern for along time by
pre-installing such programs at your side.
17) This phenomena (image retention) is not deterioration of LCD. If it happens, you can remove it by
applying different patterns.




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
Global LCD Panel Exchange Center www.panelook.com

SPEC No. MODEL No. PAGE
LC00303 LM130 SS1 T611 4


18) CCFT backlight should be kept OFF during VDD is "L" level.


WARNING
Don't use any materials which emit following gas from epoxy resin (amines' hardener) and silicone
adhesive agent (dealcohol or deoxym) to prevent change polarizer color owing to gas.




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
Global LCD Panel Exchange Center www.panelook.com

SPEC No. MODEL No. PAGE
LC00303 LM130 SS1 T611 5


Page
[Precautions] ............................................................................................... 1
1. Application.............................................................................................. 6
2. Construction and Outline......................................................................... 6
3. Mechanical Specification......................................................................... 7
4. Absolute Maximum Ratings .................................................................... 7
4-1. Electrical absolute maximum ratings................................................. 7
4-2. Environment Conditions ................................................................... 8
5. Electrical Specifications .......................................................................... 9
5-1. Electrical characteristics ................................................................... 9
5-2. Interface signals.............................................................................. 11
5-3. Interface timing ratings................................................................... 16
6. Module Driving Method ........................................................................ 17
6-1. Circuit configuration....................................................................... 17
6-2. Display face configuration.............................................................. 17
6-3. Input data and control signal ........................................................... 17
7. Optical Characteristics........................................................................... 19
8. Characteristics of Backlight ................................................................... 24
8-1 Rating(Note).................................................................................... 24
8-2 Measurement equipment :................................................................ 24
8-3 Measurement equipment :................................................................ 24
8-4 Measurement conditions .................................................................. 24
8-5 Used lamp : ..................................................................................... 24
9. Supply voltage sequence condition ........................................................ 26
10. Applicable inspection standard ............................................................ 27
11.Lot Number .......................................................................................... 27
11. Outline dimensions .............................................................................. 28




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
Global LCD Panel Exchange Center www.panelook.com

SPEC No. MODEL No. PAGE
LC00303 LM130 SS1 T611 6


1. Application
This data sheet is to introduce the specification of LM1 30SS1T 611, Passive matrix type color LCD module.


2. Construction and Outline
Construction: 800 600 dots color display module consisting of an LCD panel, PWB (printed wiring
board) with electric components mounted onto, TCP (tape carrier package) to connect
the LCD panel and PWB electrically, and plastic chassis with CCFT backlight and bezel
to fix them mechanically.
Signal ground (VSS) is connected with the metal bezel.
DC/DC converter is built in.




PW B TCP L C D p anel B ezel
(w ith A n ti -gla re tr e a tm e n t, P e n c il h a r d n e s s 3 H )




L ig h t P ip e CCFT
P la stic c h a s sis B ezel




Outline :See Fig. 14
Connection :See Fig. 14 and Table 6




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
Global LCD Panel Exchange Center www.panelook.com

SPEC No. MODEL No. PAGE
LC00303 LM130 SS1 T611 7


3. Mechanical Specification


Table1

Parameter Specifications Unit
Outline dimensions 295.0