Text preview for : chap02.pdf part of HP Designjet This is the service manual for designjet models 250,330, and 350C.



Back to : about.pdf | Home

2

Site Planning and Requirements

21

Power Requirements
HP DesignJet 230 and 330 and HP DesignJet 250C and 350C plotters have self adjusting power supplies and do not require a voltage selector or switch settings prior to use. The table below lists the power requirements for the plotters. Power Requirements
Source Voltage Requirements: Voltage 100 V ac 120 V ac 220 V ac 240 V ac Normal Operating Range: Frequency: Consumption: 90 to 264 V ac 47-63 Hz 140 watts maximum Max current (rms) 1.40 A 1.17 A 0.64 A 0.60 A

WARNING

The ac power outlet (mains) must have a protective earth (ground) terminal. Serious shock hazard leading to death or injury may result if the plotter is not properly grounded.

Choosing an Interface Cable
(Instructions ' User's Guide, chapter 1, w Connect the plotter to your computer.)
Serial (RS 232 C) Interface A short cable (less than 15 meters or 50 feet) is recommended

for the RS 232 C interface. A longer cable is permissible, provided the load capacitance does not exceed 2500 picofarads.

Parallel (Bi Tronics/Centronics) Interface Use a short cable (less than 2 meters or 6.6 feet)

for the parallel interface.

(Interface descriptions ' Service Manual, chapter 5, w Input/Output Interfaces.)
230 250C 330 350C

(Pin specifications ' User's Guide, chapter 5, w Interface specifications.) (Pin specifications ' User's Guide, chapter 10, w Interface specifications.) (Cable part numbers ' Service Manual, chapter 10.)

22

Site Planning and Requirements

C4699 90000

Choosing a Suitable Plotter Environment
(Instructions ' User's Guide, chapter 1, w Position the plotter.) Environmental Specifications
Hardware: Operating environment: Plotter With cartridges and media: Storage environment: Plotter/media Cartridges Environmental Class B2 Temperature 0 to 55_C (32 to 131_F) 15 to 35_C (59 to 95_F) Temperature ­40 to +70_C (­40 to +158_F) ­40 to +40_C (­40 to +104_F) Sound Pressure D/A1-size plotters E/A0-size plotters 43 dB (Acoustic) 45 dB (A) < 20 dB (A) Sound Power 6.0 bels (A) < 3.6 bels (A) Relative Humidity 5-25% 20-80% Relative Humidity 5-95%

Acoustics:* Operating Idle assumes fan is off.

*These specifications are typical sound pressures at a one meter bystander position. Idle specification

Plotter Dimensions and Weight
Plotter Model: Length Depth Height (window closed) Weight D/A1-size plotters 1028 mm (40.5 in) 237 mm (9.3 in) 327 mm (12.9 in) 26 kg (57.2 lb) E/A0-size plotters 1327 mm (52.2 in) 237 mm (9.3 in) 327 mm (12.9 in) 31 kg (68.2 lb)

C4699 90000

Site Planning and Requirements

23

Notes

24

Site Planning and Requirements

C4699 90000