Text preview for : Why Upgrade to the 90000 X-Series_ Infiniium 90000 X-Series versus 90000A Series Oscilloscopes 5991- part of Agilent Why Upgrade to the 90000 X-Series Infiniium 90000 X-Series versus 90000A Series Oscilloscopes 5991- Agilent Why Upgrade to the 90000 X-Series_ Infiniium 90000 X-Series versus 90000A Series Oscilloscopes 5991-1039EN c20140916 [2].pdf



Back to : Why Upgrade to the 90000 | Home

Keysight Technologies
Why Upgrade to the 90000 X-Series?
Infiniium 90000 X-Series versus 90000A Series Oscilloscopes

Upgrade to the 90000 X-Series and start making better measurements today
1. Dramatically improved signal integrity--Pick a spec: noise floor, jitter, ENOB, SFDR, 90000 X-Series 90000A Series
not only is the X-Series a dramatic signal integrity improvement over the 90000A, it
Analog channels
has the best signal integrity of any real-time oscilloscope, period.
Max analog bandwidth 33 GHz 12 GHz
2. Bandwidth upgradability to 33 GHz--The 90000 X-Series features a max sample rate
Max bandwidth (4 channel) 16 GHz 13 GHz
of 80 GSa/s and upgradability to 33 GHz of true analog bandwidth. You can buy a
13 GHz model now and upgrade all the way to 33 GHz as your needs evolve. Max memory depth 2 Gpts - 4 channels 1 Gpts - 4 channels
Sample rate 80 GSa/s 40 GSa/s
3. Available MSO--Get 16 digital channels (+ 1 for triggering), and the world's highest
20 GSa/s digital channel sample rate. This is the greatest analog bandwidth and Noise floor @ 13 GHz 1.2 mVrms 1.45 mVrms
signal integrity MSO in the industry. Noise floor @ 33 GHz 2.02 mVrms Not available
Jitter measurement floor 150 fs 600 fs
Bandwidth upgradable Yes, to 33 GHz Yes, to 13 GHz
Digital channels
Max 8 channel sample rate 20 GSa/s
Max 16 channels sample rate 10 GSa/s
Max memory depth 400 Mpts Not available
17th channel for triggering Yes
Specialized DDR1/2/3 triggering Yes
Better measurements within reach
How did we achieve this?
The 90000A Series offers category-leading signal integrity and performance up to 13 GHz. However, the latest technological
innovations from Keysight Technologies, Inc. have enabled a real-time oscilloscope that is superior to the 90000A Series and
competing scopes in every critical performance metric. The 90000 X-Series uses custom Indium Phosphide chips to achieve true
analog bandwidth from 13 GHz up to 33 GHz. Keysight's technology leadership and commitment to signal integrity ensure you get
the highest measurement accuracy, whether you are using 13 GHz of bandwidth or 33 GHz.

The result: the best signal integrity ever on a real-time oscilloscope. Pick a signal integrity specification, the 90000 X-Series will
be the industry's best at comparable bandwidths. Lowest noise floor? Of course. Lowest jitter measurement floor? Absolutely.
Highest ENOB? Greatest SFDR? Yes and yes.

From 13 GHz to 33 GHz, with the 90000 X-Series better measurements are within reach.



Protect your investment
The 90000 X-Series supports compatibility across both the InfiniiMax II and InfiniiMax III family of probes. You don't have to throw
away your probing investment to upgrade to the 90000 X-Series. In fact, every new 13 GHz 90000 X-Series comes with 2 free
InfiniiMax II probe adapters to make sure your measurement needs are met the moment the scope hits your bench.

Get into the 90000 X-Series family of real-time oscilloscopes today and enjoy upgradeability to 33 GHz of true analog bandwidth,
2 Gpts acquisition memory, and the InfiniiMax III family of probing solutions.



Combining deep logic analysis with the industry's highest performance oscilloscope
Now Keysight's 90000 X-Series can be purchased as a mixed signal oscilloscope. The integrated 8/16 digital channels + 1 additional
channel for triggering offer the industry's fastest sample rate and deepest memory. The MSOX90000 Series represents the highest
bandwidth and most accurate MSO in the industry.




www.keysight.com/find/90000X-Series


This information is subject to change without notice.