IMPORTANT SAFETY NOTICES

PREVENTION OF PHYSICAL INJURY
1. Before disassembling or assembling parts of the copier and peripherals,
make sure that the copier power cord is unplugged.
2. The wall outlet should be near the copier and easily accessible.
3. Note that some components of the copier and the peripherals are
supplied with electrical voltage even if the main switch is turned off.
4. If any adjustment or operation check has to be made with exterior covers
off or open while the main switch is turned on, keep hands away from
electrified or mechanically driven components.
5. The inside and the metal parts of the fusing unit become extremely hot
while the copier is operating. Be careful to avoid touching those
components with your bare hands.
6. The copier is not attached to the table. Pushing the copier too hard may
cause it to drop onto the floor. While moving the copier, push the table.
7. When the main switch is turned on, the machine will suddenly start turnig
to perform the developer initialization. Keep hands away from any
mechanical and electrical components during this period.


HEALTH SAFETY CONDITIONS
1. Never operate the copier without the ozone filters installed.
2. Always replace the ozone filters with the specified ones at the specified
intervals.
3. Toner and developer are non-toxic, but if you get either of them in your
eyes by accident, it may cause temporary eye discomfort. Try to remove
with eye drops or flush with water as first aid. If unsuccessful, get medical
attention.
OBSERVANCE OF ELECTRICAL SAFETY STANDARDS
1. The copier and its peripherals must be installed and maintained by a
customer service representative who has completed the training course
on those models.
2. Caution: The RAM pack on the main control board has a lithium battery
which can explode if replaced incorrectly. Replace the RAM pack only
with an identical one. The manufacturer recommends replacing the entire
RAM pack. Do not recharge or burn this battery. Used RAM packs must
be handled in accordance with local regulations.

SAFETY AND ECOLOGICAL NOTES FOR DISPOSAL
1. Do not incinerate the toner cartridge or the used toner. Toner dust may
ignite suddenly when exposed to open flame.
2. Dispose of used toner, developer, and organic photoconductors
according to local regulations. (These are non-toxic supplies.)
3. Dispose of replaced parts in accordance with local regulations.
4. When keeping used RAM packs in order to dispose of them later, do not
put more than 100 RAM packs per sealed box. Storing larger numbers or
not sealing them apart may lead to chemical reactions and heat build-up.
SECTION 1
OVERALL MACHINE INFORMATION
31 October 1994 SPECIFICATIONS



1. SPECIFICATIONS
Configuration: Table top
Copy Process: Electrostatic transfer system
Original Feed: Sheet feed
Original Size: Maximum: 914 x 2,000 (36" x 80")mm
Minimum: A4 (81/2" x 11") lengthwise
Copy Size: Same as "Original Size"
Copying Speed: 3 cpm (A1/D sideways)
First Copy: 24 seconds (A1/D sideways)
Warm-up Time: Within 5 minutes (Room temperature 23oC)
Multi-Copy: 1 to 1 only
Automatic Reset: 2 minutes after copying is finished (can be set
to 1, 3, 4, or 5 minutes or to no auto reset)
Photoconductor: Organic photoconductor drum
Drum Charge: Single-wire with grid plate (Negative Charge)
Reproduction Ratio: 1 : 1 (