Text preview for : _de-umidifier_©_.pdf part of Philips HR4165 Service Manual Freon Type R134a/160g - pag. 4



Back to : _de-umidifier_©_.pdf | Home

DE-HUMIDIFIER

Service Service
Philips Domestic Appliances and Personal Care

HR4165

Service Manual
MSH coding 8834 165 00000
PRODUCT INFORMATION Type Voltage Frequency Power consumption Water storage capacity Maximum capacity Freon type : : : : : : : HR4165 220-230V 50 Hz 220W 2.4 liters 8.1 liters per day at 30°C / 80% RH R134a / 160g Feature ON/OFF switch pilot light High/Low speed fan button Water FULL pilot light indication Automatic shut-off when water tank is full or removed.

SERVICE INFORMATION In case a technical defect in compressor, the appliance has to be replaced. After repair, place the appliance in a up-right position and wait for 3 minutes before switch ON. This is to allow the Freon liquid to flow back to the compressor.

Published by Philips Domestic Appliances and Personal Care

Printed in Hong Kong

© Copyright

reserved

Subject to modification

4822 729 22092 Ver. 1 01/99

SERVICE PARTS

EXPLODED VIEW

Item Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Bucket Bucket floater Air filter Carbon filter Filter cover Handle set Top cover + Inlay Main control board Control switch Fan speed switch Knob set Front panel Cabinet Tube set Fan blade Motor Transformer Resistor Humidity sensor Micro switch Rubber plug Power cord HK Compessor starter

Service code 4822 418 10422 4822 402 11288 4822 480 10263 4822 480 10264 4822 442 01785 4822 498 10729 4822 442 01786 4822 214 13036 4822 277 11865 4822 277 11866 4822 410 12343 4822 459 05269 4822 441 12318 4822 530 10525 4822 515 10069 4822 361 11166 4822 146 11135 4822 101 11945 4822 132 00126 4822 277 11867 4822 462 11173 4822 321 11494 4822 280 10384

19

12 5 2 3 4

1

8 19 17

11

7 18 16

6

15

8 20 10 14 9 13

23

21

22

FULL TANK SENSOR HUMIDITY SELECTOR

HR4165

MAIN BOARD JP8 CN2 JP3 JP1 RES. FAN MOTOR JP7 JP4 COMPRESSOR UNIT AC 220V FAN SPEED SELECTOR CN1 JP2

TEMP. SENSOR

JP5

JP6

HUMIDITY SELECTOR

STARTER

COMPRESSOR

OLP

TRANSFORMER

LED BOARD

JP6A

CN3

CN4

OLP : OVER LOAD PROTECTOR