Text preview for : _vacuum_cleaner_©_.pdf part of Philips HR8701 Service Manual ser. Vision - pag. 6



Back to : _vacuum_cleaner_©_.pdf | Home

Vision

Vacuum cleaner HR 8701

!

Service Information

!

Service Information

Philips Domestic Appliances and Personal Care

PRODUCT INFORMATION
- - - - - - Maximum air displacement Maximum vacuum water column Power consumption (IEC) 225V Dust storage capacity Cord length (depends on version) Filter system (depends on version) : : : : : : : : : : : 34 l/sec. 275 cm 1200W 4 litres 6 or 8.5 metres Paper dustbag Exhaust air filter Motor inlet filter 48 x 30 x 25 cm 6.4 kg 75 dB

SERVICE INFORMATION
- To open the appliance, first remove the panel (item 13) with a big screw driver (V) to disconnect the 4 snap locks (the 4 screws of button panel item 39 can be loosed) and then remove the two pedals (items 1 and 14) with a pin (W), max. diameter 2.5 mm. - Power meter (8838 000 60300) is a commercial item with a fixed air displacement which measures the vacuum of the appliance. - Component configuration on exploded view may differ in case of specific versions. However, the actual components are distinguished by means of code numbers. - If a repair has been made, make sure that all functions of the appliance are working correctly. - The spare parts have been standarized as much as possible. - Item 16 Cotton dustbag is used in those countries where paper dustbags are not available. - Item 21 is provided with the long cord-winder spring; both long and short cords can be used in combination with this spring. - To disassemble the cordwinder use TORX screw driver no T15, which is one of a set consisting of T20, T15, T10, T9, T8, T7 and T6 = 4822 395 50145. - Depending on the original cord, the spare cord must be shortened from 8.5 into 6 metres. - Item 34. Remove the control lever. - Item 43 air valve opens to cool the motor if the air displacement is too low or if the air flow is blocked.

- Dimensions cleaner - Weight without accessories - Noise

OPTIONAL
Exhaust air filter Cotton dustbag Paper dustbag set Paper dustbag set Hard floor nozzle Dust sensor Turbo brush HR 6932 (8836 932 01210) HR 6935 (8836 935 01013) HR 6938 (8836 938 06110) economy HR 6938 (8836 938 10110) hygiene HR 6943 (8836 943 03010) HR 6953 (4322 004 21250) HR 6988 (8836 988 01010)

ADJUSTING THE PCB ON THE MOTOR TO 220V, 60Hz
1. Make sure that the potentiometer (item 58) is set at min. position. 2. Adjust the potentiometer on the PCB (item 44) on the motor to 220V/60Hz. to allow the motor to run smootly. Please note: * that the standard setting of the PCB is 230V, 50Hz.

* that there are open-circuit voltages on all wires.
After the product has been repaired, it should function properly and has to meet the safety requirements as laid down officially established at this moment.

Product meets the requirements regarding interference suppression on radio and TV.

Published by Philips Domestic Appliances and Personal Care

Printed in the Netherlands

© Copyright reserved

Subject to modification

4322 277 00072 99/08
PCS 101 287

1 2 3 5 6 7 8 9 10 11 12 13 14 16 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 35 36 37

4322 003 10700 4322 005 04770 4322 009 07090 4322 005 06650 4322 001 72800 4322 009 06420 4322 001 71960 4322 003 10650 4322 000 03800 4322 003 10640 4322 003 10630 4322 009 07280 4322 003 10710 8836 938 10110 8836 935 01013 4322 009 06410 4322 009 07270 4322 009 05350 4322 003 10470 4322 001 72360 4322 009 04800 4322 009 05060 4322 007 11960 4322 007 12150 4322 006 01620 4322 007 12190 4322 007 11920 4322 007 11930 4322 007 12020 4322 007 11950 4322 003 10420 4322 005 04700 4322 000 03790 4322 001 98860 4322 005 04750

cord-winder pedal accessory cover (standard) acc. cover spring acc. cover lock diaphragm valve swivel connector sealing rubber dust cover dust-cover spring dust-cover snaplock cord-winder lever version panel switch pedal paper dustbag hyg. cotton dustbag (opt.) dustbag holder dust chamber reel half spring unit connection piece brake tyre reel half contact unit contact-ring plate cordset Australia cordset Japan (2 x 1.25 mm2) cordset (2 x 0.75 mm2) cordset UK cordset L = 8.3 m 4.8 mm pins cordset L = 6.3 m 4.8 mm pins cordset cordset lower housing caster assy button spring switch lever parking hook

38 39 40 41 42 43 44 45 46 47 48 49 50 52 53 54 55 56 57 58 120 121 122 123 125 126 127 129 130 131 DFU

4322 006 50580 4322 003 10620 4322 003 10590 4322 000 37300 4322 009 07040 4322 005 04730 4322 006 20720 4322 003 10430 4322 003 11580 4322 003 10570 4322 003 10580 8836 932 01210 4322 009 06400 4322 001 72790 4322 003 09720 4322 000 03700 4322 009 06430 4322 001 72780 4322 003 09820 4322 006 20760 4322 009 05400 4322 002 22610 4322 009 05410 4322 004 21050 4322 004 21500 4322 005 03770 4322 004 22110 4322 003 07620 4322 004 21160 4322 004 21170 4222 000 46850 West Europe

main switch button panel upper housing safety filter Trio safety filter + grille air inlet valve 220-240V power module dt 230V rear wheel rear wheel cap cord outlet back grille AFS filter motor housing back motor buffer suspension bracket PCB mounting spring motor 1241 - 230V front motor buffer motor disc 1241 potentiometer 220-240V metal-tube clip metal-tube telesc. -tube clip (opt.) telescopic tube (opt.) eco bend + hose eco bend nozzle crevice nozzle small nozzle brush nozzle West Europe total

English Norwegian German Danish French Swedish Dutch Finnish Portuguese Turkey Spanish Greec Italian

V W
CONNECTOR CORD WINDER

V

MAIN SWITCH

W
M
MOTOR POWER MODULE MAX

MIN

12

1

13 14

2

3

58

16

18 5

20 21÷31 7 6 8 9 10 32

11 33

(4x)

47 35 36 37 38 39 48

40

49

50

41 42

43

52 53 54

44 45

55

56 57 46

DAP0943

PCS 101 288

120

122

125 121 123 126

137

129 127

130

131

AUSTRALIA 26

EUROPE Ø 4.8mm

29

22 GB 28 ITALY 31

FLAT PINS

27

CH

30

23

24 B

21

25

B

DAP0409