Text preview for : air_cleaner_®_.pdf part of Philips HR 4345/A Service Manual Air Cleaner 70W (97/06) - pag. 4



Back to : air_cleaner_®_.pdf | Home

Air Cleaner HR 4345/A

Philips Domestic Appliances and Personal Care

PRODUCT INFORMATION GENERAL The HR 4345 is suitable for room / areas with a floor surface of up to approx. 40 m2. The air cleaner cleans the air effectively by catching 90 % of the gases and 95 % of the particles produced by smoking. This is done by 3 filters : Foam pre-filter : The foam pre-filter catches the larger dust particles floating in the air, such as fluff and hairs.

FEATURES Filter full indicator: Once the indication light comes on, the filter has to be replaced. After replacement of the filters, the filter full indicator has to be reset. The reset button has to be pressed and hold for at least 3 seconds. The indication light remains ( or comes ) on. After some time it will go out to indicate that the indicator has been reset. Electronic speed setting: 0 - 1 - 2 and turbo. Safety lock: The front cover has a safety lock. A nock of the frontcover operates the microswitch of the PCB when the front cover is closed. Once the front cover is removed the microswitch interrupts the electric circuit and the motor stops. Over heating safety device: The overheating safety device comes into operation when the motor becomes too hot. To indicate that the appliance is still in " ON " position and connected to the mains, the pilot light remains on. If this happens : - Switch off the motor. - After approx. 15 min. the air cleaner can be switched on again. TECHNICAL DATA Voltages : 100 volt, 50 Hz : 70 Watts 110 - 127 volt, 60 Hz : 120 Watts 220 - 240 volt, 50 Hz : 70 Watts : 2 carbon filters : HEPA filters : 6 months : carbon filters : 3 months : 157 m3 : 230 V, 50 Hz : 190 m3 : 120 V, 60 Hz : 1 m2 : Max. 40 m2
Subject to modification

HEPA filter HR4920 : This filter takes out the remaining smaller particles. Carbon filter : The carbon filter with activated carbon granulates (HR4941) effectively absorbes the smoke gases.

This product meets the requirements regarding interference suppression on radio and TV.

Filters Life time filters Flow rate Total filter surface Room / area size
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands

© Copyright reserved

4822 729 21841 97/06
PCS 88 812

POSSIBLE COMPLAINTS 1) The motor makes an irritating noise. Check if : - The carbon filters are positioned properly in the air cleaner. : - The filters have to be cleaned or replaced. : - The fan has been properly fitted and can be rotated freely by hand. 2) The overheating device comes into operation. Check : If the filters are blocked and nothing is obstructing the air inlet and air outlet openings. : That the fan has been fitted properly and can rotated freely by hand.

PARTS LIST HR 4345/A POS DESCRIPTION 1 front cover containing : frame foam filter cover 1 11 100 4822 418 10132 4822 480 10085 4822 310 11051 4822 310 11054 4822 214 12413 4822 310 11052 4822 464 10344 4822 458 10463 SERVICE CODE 4822 442 00118

2 3 4 5 6 7 8 9 10

container carbon granules HEPA filter control panel + insert 116 components detector, item 116,117,118 pcb control unit microswitch + bracket frame pcb air outlet

In case these problems still remains, replace the motor (item 13.0) and belonging buffers (item 13.1).

MAINTENANCE Pre-filter : Wash or vacuum clean the foam pre-filter at least every 2 months. Fluff and /or hairs can also be removed by using a soft brush. Replacement filters are available under service code 4822 480 10086 NEVER USE WET FILTERS. 11 12

front housing 4822 310 10978 consisting of : front housing 10 hole plug 105 safety grill 106 2x foot 107 2x foam pre-filter fan containing : fan lock washer washer nut M6 nut cover 12 108 109 110 111 4822 361 10779 4822 361 10781 4822 361 10786 4822 310 10981 rubber buffers 112 3x metal bracket 113 3x bush 115 3x 4822 310 10982 14 107 2x 4822 442 00119 4822 390 10139 4822 123 14028 4822 310 11053 4822 214 12414 4822 214 12415 4822 214 12412 4822 480 10086 4822 310 10979

HEPA filter : For a proper operation replace these filters at least every six months. Replacement HEPA filters are available under type number HR4940 and service code 4822 480 10085. Carbon filter: Replace the carbon granules at least every 3 months. New carbon granules are available under type number HR4941 and service code 4822 390 10139.

13.0 motor 220 - 240 V motor 110 - 120 V motor 100 V 13.1 set buffers containing:

14

rear housing consisting of: rear housing foot rear cover carbon granules capacitor 110 - 127 V housing parts supply pcb supply pcb 220 - 240 V supply pcb 110 - 120 V supply pcb 100 V

15 16 17 18

NOTES * Concerns Panel 4 : for standardisation reasons, the insert 119 of the Air Cleaner HR 4325 is delivered too. * After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as laid down and officially established at this moment.

19

Parts, with numbers from 100 and higher, cannot be ordered separately.

PCS 88 813