SAP coding HI 922 PRODUCT INFORMATION Feataures : inox sole plate boiler capacity 1 litre length steam hose 1,9 metre length cord set 1,9 metre maximum steam output 60 gr/min : 220-240 Volt : 50-60 Hz : Boiler Pressure Iron : 1200 Watt : 2,5 bar : 800 Watt Voltage Frequency Power consumptium

Product meets the requirements regarding interference suppression on radio and television. - After the product has been repaired, it should function properly and has to meet the safety requirements as laid down officially established at this moment.

Published by Philips Domestic Appliances and Personal Care

Printed in the Netherlands

© Copyright reserved

Subject to modification

4322 277 00126 00/02
PCS 101 361

EXPLODED VIEW IRON

5

4

3

21

11

7

B 1

H

15 D A E 2x 2

I 2x

8 X 9 44 12 24 13 20 22 23 17 14 13

F 2x C 6 10 16

18

G

19
Screws : A B C D E F G H I d 3.0 3.0 3.0 3.0 4.0 3.0 M4 3.0 M4 x x x x x x x x x x 1 27 25 19 6 12 9 24 9 12

DAP1102

PCS 101 362

PARTS LIST IRON Pos 1 2 3 4 5 6+7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 24 Description Insert dial Dial ring Microswitch Lever microswitch Cover microswitch Handle right + left part Swivel, colour black Steam hose / electric cable Pilot light Cork grip Clamping ring Clamping ring Sleeve Connecting bracket therm. Metal cover Insulating bracket Sole plate + pos. 19 Thermostat Insulating plate Bracket + item 22 and 23 Hose joint Service Nummer 9965 000 02085 4822 532 12772 4822 282 30239 9965 000 02086 4822 442 00787 4822 310 10944 4822 325 10193 4822 530 10377 4822 134 10076 4822 498 10638 4822 492 71001 4822 532 12742 4822 325 10194 4822 402 10689 4822 442 00788 4822 466 11473 4822 259 10234 4822 282 30238 4822 466 11474 4822 310 10945 4822 526 10669

DISASSEMBLY ADVISE IRON DIAL 1 RING 2

MICROSWITCH 3 LEVER MICROSWITCH 4
remove SCREW A remove COVER MICROSWITCH 5 lift MICROSWITCH 3 unsolder WIRING

TABLE UNIT
p

IRON
Cut out

Steamvalve

Steamswitch
Cut out

Thermostat

IRON REPLACE HANDLE 6 + 7
remove remove remove remove SCREW B SCREW C SCREW D SCREW E

REPLACE COVER 16 REPLACE SOLE PLATE 18 REPLACE THERMOSTAT 19

THERMOSTAT 19 ONLY
cut CONDUCTOR A at location P remove SCREW J

ASSEMBLY REQUIREMENTS THERMOSTAT 19
Instead of metal conductor A, the new thermostat has a wire with AMP clamp. After fixing screw J, connect the AMP clamp to tag Q. After assembling cover 16 ALWAYS turn conductor B through 180 degrees.

D

REPLACE INSULATING PLATE 20 C
remove DIAL 1 remove RING 2 remove HANDLE PARTS 6+7 remove HOSE remove SLEEVE remove CORK GRIP remove SCREW I remove BRACKET 21 turn conductor B through 180 degrees

P Q B D A

E B

REPLACE SWIVEL 8 REPLACE HOSE 9 REPLACE PILOT LAMIP 10
disassemble HANDLE PARTS 6+7 remove SCREW F 2 x remove CONNECTING WIRES remove CLAMP( S )

ADJUSTMENT AND CONTROLS Thermostat 19 Thermostat ( 19 ) supplied as a spare part or fitted to the sole plate ( 18 ) has already been adjusted by the supplier and secured by glue. To avoid disfunction of the iron , NEVER readjust the thermostat.

REPLACE CORK GRIP 11
disassemble HANDLE PARTS 6+7 remove SCREW G remove SCREW H

remove PLATE 17

NOTE : For opening you need a Torx screwdriver 362 TR T20 x 100.

PCS 101 363

EXPLODED VIEW STAND

D 31

33

32

30

E

35 40

36 34

42

41 37

39 36

43 38

DAP1103

PCS 101 364

PARTS LIST + DISASSEMBLY ADVICE STAND Pos 30 31 32 33 34 35 36 37 38 39 40 41 42 43 DFU Description Stand rubber feet Rubber feet above screw Complete tray Safety valve Rubber ring in filling hole Cover Rubber feet boiler Boiler complete Locked insert Bottom housing Filter Switch Electro valve Cordset Italian plug Cordset Europe plug GBR, FRA, DEU, NLD, ESP, PRT, ITA Service Nummer 9965 000 01692 9965 000 01702 9965 000 01861 9965 000 01862 9965 000 01866 9965 000 01867 4822 462 71999 9965 000 01868 9965 000 01788 9965 000 01789 9965 000 01790 9965 000 01791 4822 218 11561 9965 000 01792 9965 000 01793 4222 001 92450 OPEN THE STAND

D

Below rubber feet remove SCREW D (1 x)

E E

E

ADJUSTMENT AND CONTROLS ­ To avoid leakage of the sealings and damage to the components in and on the boiler, NEVER clean the boiler with vinegar, a descaling agent or other chemicals. ­ The boiler doesn't contain serviceable parts. Never disassemble the boiler body and /or components on and in the boiler. ­ ALWAYS REPLACE THE BOILER ( 37 ) WHEN:
remove SCREW E (3 x)

* *

the mechanical safety valve ( 33 ) has been activated. the boiler thermostat or hand - resettable safety thermostat are open, because the boiler has been subjected to too high temperatures. the electrovalve ( 42 ) fails or the sieve is soiled with scale.

remove LOCKED INSERT 38 NOTE: OPEN NOW THE STAND. DON'T WORRY IF THE SNAPS AT THE SIDE WILL BE BROKEN. THEY ARE ONLY FOR THE ASSEMBLY. THE STAND REMAINS CLOSE WITHOUT THESE SNAPS.

*

­ After the product has been repaired, it should function properly and has to meet the safety requirements as laid down and officially established at this moment.