Text preview for : iron_provapor_vario_®_.pdf part of Philips HI914 Service Manual Provapor Vario Elance 220V 800+1200W [3,0 bar] - pag. 6



Back to : iron_provapor_vario_®_.pd | Home

Provapor vario elance HI 914

! !

Service Information

!

Service Information

Service Information

Philips Domestic Appliances and Personal Care

Service Manual
SAP coding HI 914 PRODUCT INFORMATION Feataures : inox sole plate boiler capacity 1 litre length steam hose 1,9 metre length cord set 1,9 metre maximum steam output 70 gr/min steam ready indicator boiler empty indicator : 220-240 Volt : 50-60 Hz : Boiler Pressure Iron : 1200 Watt : 3 bar : 800 Watt Voltage Frequency Power consumptium

Product meets the requirements regarding interference suppression on radio and television. - After the product has been repaired, it should function properly and has to meet the safety requirements as laid down officially established at this moment.

Published by Philips Domestic Appliances and Personal Care

Printed in the Netherlands

© Copyright reserved

Subject to modification

4322 277 00123 99/10
PCS 101 316

EXPLODED VIEW IRON

10

15 1 11 13

3 2

4 B B 5 B

6 A 12 13 C

C

7 14

9

Screws :

d 3.5 3.5 M4

x x x x

1 12 14 (3x) 124 (3x)

9

A B C

DAP0996

PCS 101 317

PARTS LIST IRON Pos 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Description Inlay Micro switch Steam command lever Therm. dial Extention piece Handle Rattle Skirt Soleplate Lamp Ball swivel Back plate Thermostat Spring clamp Intermediate cable Service Nummer 9965 000 01887 9965 000 01888 9965 000 01680 9965 000 01681 9965 000 01682 9965 000 01683 4822 492 71445 9965 000 01684 9965 000 01685 9965 000 01686 9965 000 01687 9965 002 01689 9965 000 01690 4822 492 71001 9965 000 01691

TABLE UNIT
p

IRON
Cut out

Steamvalve Dry thermostat Steamswitch

Cut out

Thermostat

DISASSEMBLY ADVISE IRON BACK PLATE 12
remove SCREW A

HANDLE 6
cut

THERMOSTAT 13 ONLY
CONDUCTOR A at location P

ASSEMBLY REQUIREMENTS THERMOSTAT 2
Instead of metal conductor A, the new thermostat has a wire with AMP clamp. After fixing screw D, connect the AMP clamp to tag Q. After assembling SKIRT 8 ALWAYS turn conductor B through 180 degrees.

INLAY 1

remove SCREW D

P Q
remove THERM. DIAL 4 remove SCREW B (4x)

B D

A

ADJUSTMENT AND CONTROLS
unlock HANDLE carefully remove LAMP 10 remove MICRO SWITCH 2

SKIRT 8
remove ELECTRICAL WIRES remove EXTENSION PIECE 5 remove SPRING CLAMP FROM STEAM HOSE remove SCREW C (3x) Bend back the contact points

Thermostat 13 Thermostat ( 13 ) supplied as a spare part or fitted to the sole plate ( 9 ) has already been a djusted by the supplier and secured by glue. To avoid disfunction of the iron , NEVER readjust the thermostat.

NOTE : For opening you need a Torx screwdriver 362 TR T20 x 100.

PCS 101 318

EXPLODED VIEW STAND

D 22

24

23

21

E

26 31

27 25

33

32 28 38 39 36 30 27 37

29 34

DAP1000

PCS 101 319

PARTS LIST + DISASSEMBLY ADVICE STAND Pos 21 22 23 24 25 26 27 28 29 30 31 32 33 34 36 37 38 39 DFU Description Stand rubber feet Rubber feet above screw Complete tray Safety cab Rubber ring in filling hole Cover Rubber feet boiler Boiler complete Locked insert Bottom housing Filter Switch Electro valve Cordset Italian plug Cordset Europe plug Steam dial Steam regulator Boiler empty lamp Boiler ready lamp GBR, FRA, DEU, NLD, ESP, PRT, ITA Service Nummer 9965 000 01692 9965 000 01702 9965 000 01861 9965 000 01862 9965 000 01866 9965 000 01892 4822 462 71999 9965 000 01868 9965 000 01788 9965 000 01789 9965 000 01790 9965 000 01791 4822 218 11561 9965 000 01792 9965 000 01793 9965 000 01899 9965 000 01900 9965 000 01901 9965 000 01902 4222 001 92201 OPEN THE STAND

D

Below rubber feet remove SCREW D (1 x)

E E

E

removeSCREW E (3 x)

ADJUSTMENT AND CONTROLS ­ To avoid leakage of the sealings and damage to the components in and on the boiler, NEVER clean the boiler with vinegar, a descaling agent or other chemicals. ­ The boiler doesn't contain serviceable parts. Never disassemble the boiler body and /or components on and in the boiler. ­ ALWAYS REPLACE THE BOILER ( 28 ) WHEN:

remove LOCKED INSERT 29 NOTE: OPEN NOW THE STAND. DON'T WORRY IF THE SNAPS AT THE SIDE WILL BE BROKEN. THEY ARE ONLY FOR THE ASSEMBLY. THE STAND REMAINS CLOSE WITHOUT THESE SNAPS.

* the mechanical safety valve ( 24 ) has been
activated.

* the boiler thermostat or hand - resettable
safety thermostat are open, because the boiler has been subjected to too high temperatures.

* the electrovalve ( 33 ) fails or the sieve is soiled
with scale. ­ After the product has been repaired, it should function properly and has to meet the safety requirements as laid down and officially established at this moment.