Text preview for : SONY HDR-HC9, HC9E SECTION 6 ADJUSTMENTS ADJ VER 1.1 2008.05 (9-852-225-52).pdf part of SONY HDR-HC9 SONY HDR-HC9, HC9E. DIGITAL HD VIDEO CAMERA RECORDER. SECTION 6 ADJUSTMENTS VERSION 1.1 2008.05 PART#(9-852-225-52).



Back to : SONY HDR-HC9, HC9E SECTIO | Home

HDR-HC9/HC9E
RMT-831
Ver. 1.1 2008.05
Revision History

SECTION 6 ADJUSTMENTS

ADJ

Link
Before starting adjustments
Adjusting items when replacing main parts and boards List of service tools

VIDEO SECTION ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS SYSTEM CONTROL SYSTEM ADJUSTMENTS SERVO AND RF SYSTEM ADJUSTMENTS

CAMERA SECTION ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS

VIDEO SYSTEM ADJUSTMENTS AUDIO SYSTEM ADJUSTMENTS

INITIALIZATION OF EVR DATA CAMERA SYSTEM ADJUSTMENTS ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENTS LCD SYSTEM ADJUSTMENTS

SERVICE MODE
ADJUSTMENT REMOTE COMMANDER (RM-95) ADJUSTMENT REMOTE COMMANDER (NEW LANC JIG) DATA PROCESS

MECHANISM SECTION ADJUSTMENTS
HOW TO ENTER RECORD MODE WITHOUT CASSETTE HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE TAPE PATH ADJUSTMENT

SERVICE MODE

NTSC MODEL: HDR-HC9 PAL MODEL: HDR-HC9E

HDR-HC9/HC9E_ADJ
9-852-225-51

Sony EMCS Co.

2008E0800-1 © 2008.05 Published by Kohda TEC

SECTION 6 ADJUSTMENTS

1.

Before starting adjustments EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct. Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data to a personal computer.

Download the saved data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM to the replaced board.
Remove the EEPROM and install it.

(Former board)

(New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data. Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the respective items of the EVR data. (Refer to page 6-3 for the items to be checked)

HDR-HC9/HC9E_ADJ 6-1

1-1. Adjusting items when replacing main parts and boards · Adjusting items when replacing main parts When replacing main parts, adjust the items indicated by z in the following table. Note 1: When replacing the drum assy or the mechanism deck, reset the data of page: 7, address: A8 to AB to "00". (Refer to "Record of Use check" of "6-4. SERVICE MODE")
Replaced part Block replacement Mounted part replacement

Initialization of EVR data

Camera

EVF LCD

Mechanism System control Servo, RF

Video

Initialization of A, B, D, 1A, 1B page data Initialization of 8, 9, C, 13, 18, 1C, 1D page data Initialization of F, 63 to 6F page data Initialization of 7C, 7E, 7F page data Origin oscillation check HALL adj. HALL/MR adj. Differential gain adj. Flange back adj. F No. & ND light quality standard data input Mechanical shutter adj. (1)/(2) Linear matrix adj. (1)/(2) Auto white balance standard data input LV standard data input Auto white balance adj. Color reproduction adj. MAX GAIN adj. White defect Adj. Black defect Adj. Strobe light level adj. Strobe white balance adj. Angular velocity sensor sensitivity adj. EVF automatic adj. White balance adj. LCD automatic adj. V-COM adj. Transmissive mode white balance adj. Reflective mode white balance adj. Sample hold phase adj. Touch panel adj. Tape path adj. Node uniqe ID No. input USB Serial number data setting CAP FG duty adj. Switching position adj. Error rate check S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. COMPONENT OUT Y level adj. COMPONENT OUT Pr level adj. COMPONENT OUT Pb level adj.

z z z z z z z z

z z z z z

z z z z z z z z

z z z z z z z z z z z z z z z z z z z z

z z z z z z z z z z z z z

Table 6-1-1 (1)

HDR-HC9/HC9E_ADJ 6-2

CM-077 board SE7201, 7202 VC-500 board IC1701, X1701 VC-500 board IC1201, 1301 VC-500 board IC2101 VC-500 board IC2701 VC-500 board IC3001 VC-500 board IC2001 VC-500 board IC4901 VC-500 board IC3701 BL-007 board D5901 PD-325 board IC6201 PD-325 board D6206 - 6208
z z z z z z z z z z z z z z

Adjustment Section

Adjustment

Lens device LCD block LCD901 EVF block LCD902 Flash unit Mechanism deck (Note 1) Mechanism deck M901 Mechanism deck MD block CM-077 board IC6701

(YAW, PITCH sensor) (Clock generator) (CDS, A/D converter) (Base band signal process, etc.) (DV signal process) (Video out) (Component out AMP) (REC/PB AMP) (EVF drive) (Back light (EVF)) (LCD driver) (Back light (LCD))

(LCD panel, Touch panel) (EVF unit)

(Drum motor) (Note 1)

(CMOS imager)

· Adjusting items when replacing a board or EEPROM When replacing a board or EEPROM, adjust the items indicated by z in the following table.
Replaced part

Adjustment Section

Adjustment

Supporting Radar W RadarW

BL-007 board PD-325 board VC-500 board IC1802

CM-077 board VC-500 board

Note 2: When the repair is finished, confirm the following items. 1. Shoot the all black subject (Attach the lens cap and shoot), and confirm that there is no level difference like vertical stripes in the picture. 2. Shoot a subject of low light, and confirm that there is no level difference like vertical stripes in the picture. 3. Shoot a subject of normal light, and confirm that there is no level difference like vertical stripes in the picture. When the above symptom occurs, perform the whole process of "Differencal Gain Adjustment". Note 3: IC2402 (Flash memory) on the VC-500 board and IC5202 (32M Flash memory) on the VC-500 board cannot be replaced.

(COMPLETE) (COMPLETE)

Initialization of EVR data

Camera

EVF LCD

Mechanism System control Servo, RF

Video

Initialization of A, B, D, 1A, 1B page data Initialization of 8, 9, C, 13, 18, 1C, 1D page data Initialization of F, 63 to 6F page data Initialization of 7C, 7E, 7F page data Origin oscillation check HALL adj. HALL/MR adj. Differential gain adj. Flange back adj. F No. & ND light quality standard data input Mechanical shutter adj. (1)/(2) Linear matrix adj. (1)/(2) Auto white balance standard data input LV standard data input Auto white balance adj. Color reproduction adj. MAX GAIN adj. White defect Adj. Black defect Adj. Strobe light level adj. Strobe white balance adj. Angular velocity sensor sensitivity adj. EVF automatic adj. White balance adj. LCD automatic adj. V-COM adj. Transmissive mode white balance adj. Reflective mode white balance adj. Sample hold phase adj. Touch panel adj. Tape path adj. Node uniqe ID No. input USB Serial number data setting CAP FG duty adj. Switching position adj. Error rate check S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. COMPONENT OUT Y level adj. COMPONENT OUT Pr level adj. COMPONENT OUT Pb level adj.

z z

z z z z z z z

z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

(COMPLETE) (COMPLETE) (EEPROM)
z z z z z z z z z z z z z z z z z z z

z z z z z z z z z z z z z z z z z z

z

z

z z z

Table 6-1-1 (2)

HDR-HC9/HC9E_ADJ 6-3

1-2. List of service tools · Oscilloscope · Digital voltmeter

· Color monitor · Frequency counter

· Vectorscope · Audio level meter

J-1 Adjustment remote commander (RM-95) J-6082-053-B

J-2 Adjustment remote commander (NEW LANC JIG) J-6082-565-A

J-3 LANC cable J-6082-442-A

J-4 Pattern box PTB-450 J-6082-200-A or Small pattern box PTB-1450 J-6082-557-A J-7

J-5 Color bar chart For PTB-450: J-6020-250-A For PTB-1450: J-6082-559-A J-8 Flange back adjustment jig J-6082-563-A

J-6 Clear chart For PTB-450: J-6080-621-A For PTB-1450: J-6082-560-A J-9

Minipattern box J-6082-353-B

Siemens star chart J-6080-875-A

J-10 Filter for color temperature correction (C14) J-6080-058-A

J-11 ND filter 1.0 J-6080-808-A ND filter 0.4 J-6080-806-A ND filter 0.1 J-6080-807-A J-14 Tracking standard (XH2-1) 8-967-997-01 SW/OL standard (XH2-3) 8-967-997-11

J-12

Camera table J-6082-384-A

J-13

J-15

Audio operation check for NTSC (XH5-3) 8-967-997-51 for PAL (XH5-3P) 8-967-997-55

J-16

System operation check for NTSC (XH5-5) 8-967-997-61 for PAL (XH5-5P) 8-967-997-66

J-17
A

J-18 A: CPC-15 J-6082-564-A B: I/F unit for LANC control J-6082-521-A AC power adaptor AC-L200/L200B 1-479-285-21

B

J-19

Note 1: Prepare the software (not particularly specified) capable of displaying any coordinates (in pixel) of still image data.

Personal computer (Note 1)

Fig. 6-1-1

HDR-HC9/HC9E_ADJ 6-4

6-1. CAMERA SECTION ADJUSTMENTS
1-1. PREPARATIONS BEFORE ADJUSTMENTS (CAMERA SECTION)
L = 1 m (PTB-450) L = 40 cm (PTB-1450) Pattern box L Front of the lens Camera

1-1-1. Preparations Note: Before perform the adjustment, check that the data of page: 0, address: 10 is "00". If not, select page: 0, address: 10, and set data "00". 1) Connect the equipment for adjustments according to Fig. 6-13.

Fig. 6-1-2

A/V OUT jack LANC jack

DC IN jack

RM-95 (J-6082-053-B) Vectorscope AC IN NEW LANC JIG (J-6082-565-A) LANC cable (J-6082-442-A) Adjustment remote commander Terminated 75

S Video (Black) Color monitor Video (Yellow)

Audio L (White)

AC adaptor AC-L200/L200B (1-479-285-21)

Audio R (Red)

Fig. 6-1-3

HDR-HC9/HC9E_ADJ 6-5

1-1-2. Precaution 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette. 1. 2. 3. 4. 5. 6. 7. 8. 9. POWER switch (PS24200 block) .............. CAMERA-TAPE BACK LIGHT (FP-644 flexble) .................................... OFF NIGHT SHOT switch (FP-644 flexble) ......................... OFF SCENE SELECT (MENU setting) ............................. AUTO SPOT METER (MENU setting) ................................. AUTO EXPOSURE (MENU setting) ..................................... AUTO WHITE BAL. (MENU setting) ................................... AUTO AE SHIFT (MENU setting) ................................................. 0 WB SHIFT (MENU setting) ................................................ 0 10. 11. 12. 13. 14. 15. 16. 17. FOCUS (MENU setting) ...................................... MANUAL COLOR SLOW S (MENU setting) ................................ OFF DIGITAL ZOOM (MENU setting) ................................ OFF STEADY SHOT (MENU setting) .................................. OFF D. EFFECT (MENU setting) ......................................... OFF PICT. EFFECT (MENU setting) .................................... OFF DEMO MODE (MENU setting) .................................... OFF REC FORMAT (MENU setting) ......................... HDV 1080i

2. Order of Adjustments Basically carry out adjustments in the order given. Color bar chart (Color reproduction adjustment frame)
Yellow Cyan Green White Magenta Red
H Electronic beam scanning frame C C=D=0 D

Blue

Magenta

Yellow

Green

White

Cyan

Blue

Red

CRT picture frame

A B

A=B

B A Enlargement

V

Fig. b (monitor TV picture)

Fig. a (VIDEO terminal of A/V jack output waveform)
Difference in level

B

A

Adjust the camera zoom and direction to obtain the output waveform shown in Fig. a and the monitor TV display shown in Fig. b.

Fig. 6-1-4
3. Subjects 1) Color bar chart (Color reproduction adjustment frame) When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-4. (Color reproduction adjustment frame) 2) Clear chart (AWB adjustment frame) Shoot the color bar chart. Then adjust the zoom to TELE side from WIDE side, and stop it when the black frame of the chart disappears. Remove the color bar chart from pattern box and insert a clear chart in its place. 3) Chart for flange back adjustment Join together a piece of white A0 size paper (1189 mm × 841 mm) and a piece of black paper to make the chart shown in Fig. 6-1-5. Note: Use a non-reflecting and non-glazing vellum paper. The size must be A0 or larger and the joint between the white and black paper must not have any undulations.

White 841 mm Black

1189 mm

Fig. 6-1-5

HDR-HC9/HC9E_ADJ 6-6

4. Preparing the Flash Adjustment Box A dark room is required to provide an accurate flash adjustment. If it is not available, prepare the flash adjustment box as given below; 1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2) 400 mm woody board B (2) 370 mm woody board C (1) 700 mm

513 mm

513 mm

700 mm

730 mm

700 mm

Fig. 6-1-6
2) Apply black mat paint to one side of woody board A and B. 3) Attach background paper (J-2501-130-A) to woody board C. 4) Assemble so that the black sides and the background paper side of woody board A, B and C are internal. (Fig. 6-1-7)
woody board A

woody board B

woody board A

woody board B woody board C

Fig. 6-1-7

L = 50cm

Flash adjustment box

Front of the lens

L

Camera

Background paper

Fig. 6-1-8

HDR-HC9/HC9E_ADJ 6-7

1-2.

INITIALIZATION OF EVR DATA

Initializing method: Order Page Address Data 1 2 3 0 0 7 01 10 04 01 00 Set the following data 10: HDR-HC9 11: HDR-HC9E Set the following data 20: Initializing A page 21: Initializing B page 22: Initializing D page 23: Initializing 1A page 24: Initializing 1B page 25: Initializing A and 1A page 26: Initializing B and 1B page 28: Initializing A, B, D, 1A and 1B page FF 01 Press PAUSE (Write) button. Check the data changes to "01". Perform "Modification of A, B, D, 1A, 1B Page Data" Procedure

Note 1: Pages used for the EVR consists of 26 pages. There are 8, 9, A to D, F, 13, 18, 1A to 1D, 63 to 6F pages. Note 2: When reading or writing the 13, 18, 1A, 1B, 1C or 1D page data, select page: 0, address: 10, and set data: 01, then sclect 3, 8, A, B, C or D page. The 13, 18, 1A, 1B, 1C or 1D page can be chosen by this data setting. After reading or writing, reset the data or page: 0, address: 10 to "00". Note 3: When reading or writing the 63 to 6F page data, select page: 0, address: 10, and set data: 06, then select 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, or F page. The 63, 64, 65, 66, 67, 68, 69, 6A, 6B, 6C, 6D, 6E, or 6F page can be chosen by this data setting. After reading or writing, reste the data of page: 0, address: 10 to "00". 1-2-1. Initialization of A, B, D, 1A, 1B Page Data Note: Check that the data of page: 0, address: 10 is "00". 1. Initializing of A, B, D, 1A, 1B Page Data Note: If the A, B, D, 1A, 1B page data has been initialized, the following adjustments need to be performed again. 1) Modification of A, B, D, 1A, 1B page data 2) Touch panel adjustment Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address A 10 to FF B 00 to FF D 10 to FF 1A 00 to FF 1B 00 to FF

4

7

01

5 6 7 8

7 7 7

02 00 02

HDR-HC9/HC9E_ADJ 6-8

2. Modification of A, B, D, 1A, 1B Page Data If the A, B, D, 1A, 1B page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Processing before Modification A, B, D, 1A, 1B page data: Order Page Address Data Procedure 1 2 3 4 5 6 7 0 0 7 7 7 7 7 01 10 01 02 04 00 02 01 00 38 FF 02 01 Press PAUSE (Write) button. Check the data changes to "01".

3. A Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Address 10 11 to 17 18 19 to 2E 2F 30 31 32 to 7B 7C 7D 7E 7F 80 to 8F 90 91 92 93 94 to FF E8 0E DE 19 EA 0D DD 17 Fixed data-1 (Initialized data) Touch panel adj. Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL 00 00 Test mode Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark

Modifying Method: 1) If modification of data on pages A, B, D, set data: 00 to page: 0, address: 10, and then select pages A, B, D. 2) If modification of data on pages 1A, 1B, set data: 01 to page: 0, address: 10, and then select pages A, B. After the modification of data finished, return the data on page: 0, address: 10 to "00". 3) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note 1: If copy the data built in the different model, the camcorder may not operate. 4) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 5) Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value. Processing after Completing Modification A, B, D, 1A, 1B page data: Order Page 1 2 3 4 5 6 7 8 0 7 7 7 7 7 2 2 Address 10 01 02 04 00 02 00 01 29 29 Press PAUSE (Write) button. Data Procedure 00 38 FF 01 01 Press PAUSE (Write) button. Check the data changes to "01". Press PAUSE (Write) button.

4. B Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Address 00 to D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA to FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Fixed data-1 (Initialized data) USB Serial number data setting Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

Note 2: If following symptoms occur after completing of the "Modification A, B, D, 1A, 1B page data", check that the data of the "Fixed data-2" address of A, B, D, 1A, 1B page are same as those of same model of same destination. 1) The power is shut off so that unit cannot operate.

HDR-HC9/HC9E_ADJ 6-9

5. D Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Address 10 to 15 16 17 to 27 28 29 2A 2B 2C 2D 2E 2F 30 to 35 36 37 38 39 3A 3B 3C to 57 58 59 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

6. 1A Page table Note 1: If reading/writing data on pages 1A, set data: 01 to page: 0, address: 10, and then select pages: A. By this data setting, the pages 1A can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Address 00 to 6F 70 71 72 73 74 to 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

7. 1B Page table Note 1: If reading/writing data on pages 1B, set data: 01 to page: 0, address: 10, and then select pages: B. By this data setting, the pages 1B can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Address 00 to FF Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-10

1-2-2.

Initialization of 8, 9, C, 13, 18, 1C, 1D Page Data

1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data Note 1: If "Initialization of Pages 8, 9, C, 13, 18, 1C, 1D" is executed, all data on pages 8, 9, C, 13, 18, 1C, 1D are initialized. (Only an individual page cannot be initialized) Note 2: If the 8, 9, C, 13, 18, 1C, 1D page data has been initialized, the following adjustments need to be performed again. 1) Modification of 8, 9, C, 13, 18, 1C, 1D page data 2) Electronic viewfinder system adjustments (if all areas were initialized) 3) LCD system adjustments (if all areas were initialized) 4) Node unique ID No. input (if all areas were initialized) 5) Servo and RF system adjustments (if all areas were initialized) 6) Video system adjustments (if all areas were initialized) Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data 1 2 0 0 01 10 01 00 Set the following data, and press PAUSE (Write) button. (Note 3) 00: Initializing all areas 01: Initializing other than adjustment address 0C Press PAUSE (Write) button. Check the data changes to "1C". Perform "Modification of 8, 9, C, 13, 18, 1C, 1D Page Data" Procedure 8 00 to FF 9 00 to FF C 10 to FF 13 00 to FF 18 00 to FF 1C 00 to FF 1D 00 to FF

2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data If the 8, 9, C, 13, 18, 1C, 1D page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Processing before Modification 8, 9, C, 13, 18, 1C, 1D page data: Order Page Address Data 1 2 3 0 0 3 01 10 71 01 00 01 Press PAUSE (Write) button. Procedure

Modifying Method: 1) If modification of data on pages 8, 9, C, set data: 00 to page: 0, address: 10, and then select pages 8, 9, C. 2) If modification of data on pages 13, 18, 1C, 1D, set data: 01 to page: 0, address: 10, and then select pages 3, 8, C, D. After the modification of data finished, return the data on page: 0, address: 10 to "00". 3) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 4) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 5) If all areas were initialized, check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification 8, 9, C, 13, 18, 1C, 1D page data: Order Page Address Data 1 2 3 4 5 6 0 0 3 3 2 2 01 10 70 70 00 01 29 29 Press PAUSE (Write) button. 01 00 10 Press PAUSE (Write) button. Check the data changes to "11". Procedure

3

3

81

4 5

3 3

80 80

6

Note 3: If other than adjustment address was initialized, the adjusted data is not initialized.

HDR-HC9/HC9E_ADJ 6-11

3. 8 Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data") Address 00 to AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 to C2 C3 C4 C5 C6 C7 C8 C9 CA CB to DB DC DD to E5 E6 E7 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

5. C Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data") Address 10 11 12 13 14, 15 16 17 to 24 25 26 27 28 to 30 31 32, 33 34 35 36 to 39 3A 3B 3C 3D to 3F 40 41 42 43 44 45 46 47 48 to 4A 4B 4C 4D 4E to 53 54 3F 3F 55 to 68 69 6A Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 72 6A 72 6A Reflective mode white balance adj. (LCD) 6B to 6D 6E 6F 70 71 8A 64 7A 8A 64 7A 64 6E 95 64 6E 95 V-COM adj. (LCD) Fixed data-1 (Initialized data) Transmissive mode white balance adj. (LCD) Contrast adj. (LCD) Fixed data-1 (Initialized data) Sample hold phase adj. Fixed data-1 (Initialized data) 93 7F 82 93 7F 82 Contrast adj. (EVF) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 VCO adj. (LCD) 80 8A 80 8A Fixed data-1 (Initialized data) White balance adj. (EVF) 70 8A 61 70 8A 61 E0 E0 Initial value NTSC PAL EE 00 00 00 EE 00 00 00 Fixed data-1 (Initialized data) CAP FG duty adj. Fixed data-1 (Initialized data) S VIDEO OUT Y level adj. (NTSC)/ Fixed data-1 (PAL) S VIDEO OUT chroma level adj. (NTSC)/ Fixed data-1 (PAL) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) VCO adj. (EVF) Switching position adj. Remark

4. 9 Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data") Address 00 to B7 B8 B9 BA to BC BD BE BF to FF Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-12

C Page table Address 72 to 75 76 77 78 to 84 85 86 87 88 to 92 93 94 95 96 to AA AB AC AD to F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Emergency memory address (Mechanism section) Fixed data-2 Fixed data-1 (Initialized data) 79 31 32 79 31 32 70 8A 61 70 8A 61 7A 82 7A 82 Initial value NTSC PAL Remark Fixed data-1 (Initialized data) Contrast adj. (LCD) Contrast adj. (EVF) Fixed data-1 (Initialized data) Fixed data-1 (NTSC)/ S VIDEO OUT Y level adj. (PAL) Fixed data-1 (NTSC)/ S VIDEO OUT chroma level adj. (PAL) Fixed data-1 (Initialized data) COMPONENT OUT Y level adj. COMPONENT OUT Pb level adj. COMPONENT OUT Pr level adj. Fixed data-1 (Initialized data)

6. 13 Page table Note 1: If reading/writing data on pages 13, set data: 01 to page: 0, address: 10, and then select pages: 3. By this data setting, the pages 13 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data") Address 00 to 03 04 05 06 07 08 09 0A 0B 0C to 12 13 14 to 24 25 26 to 73 74 75 to FF 08 00 46 01 02 00 00 00 08 00 46 01 02 00 00 00 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Node unique ID No. input Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

7. 18 Page table Note 1: If reading/writing data on pages 18, set data: 01 to page: 0, address: 10, and then select pages: 8. By this data setting, the pages 18 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data") Address 00 to AB AC AD AE AF to FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-13

8. 1C Page table Note 1: If reading/writing data on pages 1C, set data: 01 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 1C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data") Address 00 to B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 to FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Fixed data-1 (Initialized data) Error rate check Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

9. 1D Page table Note 1: If reading/writing data on pages 1D, set data: 01 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 1D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data") Address 00 01 02 03 04 05 06 07 08 to FF Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Remark

HDR-HC9/HC9E_ADJ 6-14

1-2-3.

Initialization of F, 63 to 6F Page Data

1. Initializing of F, 63 to 6F Page Data Note 1: If "Initialization of Pages F, 63 to 6F" is executed, all data on pages F, 63 to 6F are initialized. (Only an individual page cannot be initialized) Note 2: If the F, 63 to 6F page data has been initialized, the following adjustments need to be performed again. 1) Modification of F, 63 to 6F page data 2) Camera system adjustment Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data Procedure 1 2 3 0 0 6 01 10 01 01 00 Set the following data, and press PAUSE (Write) button. 2D: HDR-HC9 2F: HDR-HC9E 01 Press PAUSE (Write) button. Check the data changes to "01". 00 Press PAUSE (Write) button. Perform "Modification of F, 63 to 6F Page Data" F 00 to FF 63 00 to FF 64 00 to FF 65 00 to FF 66 00 to FF 67 00 to FF 68 00 to FF 69 00 to FF 6A 00 to FF 6B 00 to FF 6C 00 to FF 6D 00 to FF 6E 00 to FF 6F 10 to FF

2. Modification of F, 63 to 6F Page Data If the F, 63 to 6F page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages F, set data: 00 to page: 0, address: 10, and then select pages F. 3) If modification of data on pages 63 to 6F, set data: 06 to page: 0, address: 10, and then select pages 3 to F. After the modification of data finished, return the data on page: 0, address: 10 to "00". 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 5) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 6) Check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification F, 63 to 6F page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE (Write) button. Procedure

4 5 6 7

6 6 6

03 02 01

HDR-HC9/HC9E_ADJ 6-15

3. F Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 3E 3F 40 41 42 to FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

4. 63 Page table Note 1: If reading/writing data on pages 63, set data: 06 to page: 0, address: 10, and then select pages: 3. By this data setting, the pages 63 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 91 92 93 to CA CB CC CD to D3 D4 D5 D6 D7 D8 D9 DA to E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-16

5. 64 Page table Note 1: If reading/writing data on pages 64, set data: 06 to page: 0, address: 10, and then select pages: 4. By this data setting, the pages 64 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 0F 10 11 12 to 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 to 49 4A 4B 4C 4D Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

Address 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D

Initial value NTSC PAL

Remark

Fixed data-2

Fixed data-1 (Initialized data)

Fixed data-2

Fixed data-1 (Initialized data)

Fixed data-2

Fixed data-1 (Initialized data)

Fixed data-2

HDR-HC9/HC9E_ADJ 6-17

64 Page table Address 7E 7F 80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC to AF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL Address Remark B0 B1 B2 B3 B4 to D7 D8 D9 DA DB DC DD DE DF E0, E1 E2 E3 to EC ED EE, EF F0 F1 F2 F3 F4 to FE FF

Initial value NTSC PAL

Remark

Fixed data-2

Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2

HDR-HC9/HC9E_ADJ 6-18

6. 65 Page table Note 1: If reading/writing data on pages 65, set data: 06 to page: 0, address: 10, and then select pages: 5. By this data setting, the pages 65 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 10 11 12 13 14 15 16 17 18 19 1A 1B 1C to 1E 1F 20 to 2D 2E 2F 30 31 32 to 35 36 37 38 39 to FF Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

7. 66 Page table Note 1: If reading/writing data on pages 66, set data: 06 to page: 0, address: 10, and then select pages: 6. By this data setting, the pages 66 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 11 12 13 14 to 97 98 99 9A 9B 9C, 9D 9E 9F A0 to A6 A7 A8 to AE AF B0 to C1 C2 C3 C4 C5 to C7 C8 C9 to DF E0 E1 E2 E3 E4 to E6 E7 E8 E9 EA EB EC to EE EF F0 F1 F2 F3 F4 to F6 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-19

66 Page table Address F7 F8 F9 FA FB FC to FE FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Initial value NTSC PAL Remark

9. 68 Page table Note 1: If reading/writing data on pages 68, set data: 06 to page: 0, address: 10, and then select pages: 8. By this data setting, the pages 68 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00, 01 Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

8. 67 Page table Note 1: If reading/writing data on pages 67, set data: 06 to page: 0, address: 10, and then select pages: 7. By this data setting, the pages 67 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to B0 B1 B2 B3 to BD BE BF to FF Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

02 03 04 05 06 07 08 09 0A to 3D 3E 3F to 5D 5E 5F 60 to 6B 6C 6D 6E 6F to 8B 8C 8D 8E 8F to 9E 9F A0 to AD AE AF to BD BE BF, C0 C1 C2 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2

HDR-HC9/HC9E_ADJ 6-20

10. 69 Page table Note 1: If reading/writing data on pages 69, set data: 06 to page: 0, address: 10, and then select pages: 9. By this data setting, the pages 69 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 0D 0E 0F 10 to 72 73 74 to 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6, B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 0A E0 80 80 80 20 03 C1 FF 9F 00 00 0A E0 80 80 80 20 03 C1 FF 9F 00 00 Linear matrix adj. (1) Strobe light level adj. 0F 80 0B 00 08 C0 07 00 05 40 54 65 63 5C 4B 21 80 80 80 80 80 80 0C B0 09 10 07 20 05 A0 04 70 55 65 64 5C 4B 22 80 80 80 80 80 80 Fixed data-1 (Initialized data) Mechanical shutter adj. (1) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

Address C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 to DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 to FF

Initial value NTSC PAL FF F9 04 06 00 01 00 0E FF 48 04 32 58 76 88 55 28 D8 28 D8 19 35 00 FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 FF F9 04 06 00 01 00 0E FF 48 04 32 58 76 88 55 28 D8 28 D8 19

Remark

Linear matrix adj. (1)

HALL adj. (2)

Fixed data-1 (Initialized data) 35 00 FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Fixed data-1 (Initialized data) F No. & ND light quality standard data input LV standard data input Max gain adj. Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-21

11. 6A Page table Note 1: If reading/writing data on pages 6A, set data: 06 to page: 0, address: 10, and then select pages: A. By this data setting, the pages 6A can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to FF Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

12. 6B Page table Note 1: If reading/writing data on pages 6B, set data: 06 to page: 0, address: 10, and then select pages: B. By this data setting, the pages 6B can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 83 84 85 to BD BE BF to FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-22

13. 6C Page table Note 1: If reading/writing data on pages 6C, set data: 06 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 6C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 2E 2F 30 to 34 35 36 37 38 to 50 51 52 to 7B 7C 7D to 82 83 84 to 8B 8C 8D 8E to AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 to E2 E3 E4 E5 E6 E7 E8 E9 EA Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

Address EB EC ED EE to F0 F1 F2 F3 F4 F5 F6 F7 F8 F9, FA FB FC to FF

Initial value NTSC PAL Fixed data-2

Remark

Fixed data-1 (Initialized data)

Fixed data-2

Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-23

14. 6D Page table Note 1: If reading/writing data on pages 6D, set data: 06 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 6D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 to 05 06 07 08 09 0A 0B 0C to 2F 30 31 to 38 39 3A 3B to 49 4A 4B 4C 4D to 5F 60 61 62 63 64 65 66 67 68 to 8F 90 91 92 93 94 95 96 to 99 9A 9B 9C to 9F A0 A1 A2 A3 to A7 A8 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

Address A9 AA to BF C0 C1 C2 C3 C4 to D0 D1 D2 D3 D4 to E2 E3 E4 to FF

Initial value NTSC PAL Fixed data-2

Remark

Fixed data-1 (Initialized data)

Fixed data-2

Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-24

15. 6E Page table Note 1: If reading/writing data on pages 6E, set data: 06 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 6E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 Initial value NTSC PAL 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Differential gain adj. Remark

Address 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58

Initial value NTSC PAL 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

Remark

Differential gain adj.

HDR-HC9/HC9E_ADJ 6-25

6E Page table Address 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 Initial value NTSC PAL 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Differential gain adj. Address Remark 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 to FF

Initial value NTSC PAL 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

Remark

Differential gain adj.

Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-26

16. 6F Page table Note 1: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Address 10 to 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 12 43 54 90 22 FE 00 00 00 00 B3 19 19 45 00 06 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 80 80 80 80 40 C0 40 C0 12 43 54 90 22 FE 00 00 00 00 B3 19 19 45 00 06 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 80 80 80 80 40 C0 40 C0 MR adj. Flange back adj. MR adj. / Flange back adj. Flange back adj. Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

Address 48 49 4A 4B 4C 4D 4E 4F 50 to 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 to 79 7A 7B 7C 7D 7E 7F 80 81 82, 83 84 85 86 87 88 89 8A 8B 8C 8D 8E

Initial value NTSC PAL 40 C0 40 C0 00 00 00 00 21 B3 02 63 FE C1 FF DA 20 0A 00 2C FF 43 04 F6 1D BC 80 80 80 80 80 80 2D 64 2A 80 5E 40 14 D3 05 B0 14 B4 05 40 C0 40 C0 00 00 00 00 MR adj.

Remark

Fixed data-1 (Initialized data) 21 B3 02 63 FE C1 FF DA 20 0A 00 2C FF 43 04 F6 1D BC Fixed data-1 (Initialized data) 80 80 80 80 80 80 2D 64 Fixed data-1 (Initialized data) 2A 80 5E 40 14 D3 05 B0 14 B4 05 AWB standard data input AWB adj. Strobe white balance adj. Mechanical shutter adj. (2) Linear matrix adj. (2)

HDR-HC9/HC9E_ADJ 6-27

6F Page table Address 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 to C7 C8 C9 CA CB CC 03 AA FF B5 00 03 AA FF B5 00 Linear matrix adj. (2) Initial value NTSC PAL AC 14 AE 05 A6 14 B2 05 A5 0C 4E 09 08 0C 39 09 02 0C 34 08 FC 0C 2D 08 F3 E5 DB 6E 58 05 11 65 6C E5 DB 6E 58 05 11 65 6C AC 14 AE 05 A6 14 B2 05 A5 0C 4E 09 08 0C 39 09 02 0C 34 08 FC 0C 2D 08 F3 E5 DB 6E 58 05 11 65 6C E5 DB 6E 58 05 11 65 6C Fixed data-1 (Initialized data) Color reproduction adj. AWB adj. AWB standard data input Address Remark CD CE CF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC to EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF

Initial value NTSC PAL 30 00 01 03 F0 00 20 00 13 FF 54 04 87 04 5F 00 4C FF D0 00 00 04 0B FF E4 FF EE 00 99 03 85 14 AD 05 A7 14 95 05 AA 0C 37 09 01 0C 0A 09 02 30 00 01 03 F0 00 20 00 13 FF 54 04 87 04 5F 00 4C FF D0 00 00 04 0B FF E4 FF EE 00 99 03 85

Remark

Linear matrix adj. (2)

Fixed data-1 (Initialized data) 14 AD 05 A7 14 95 05 AA 0C 37 09 01 0C 0A 09 02 AWB adj. AWB standard data input

HDR-HC9/HC9E_ADJ 6-28

1-2-4.

Initialization of 7C, 7E, 7F Page Data

1. Initializing of 7C, 7E, 7F Page Data Note 1: If "Initialization of Pages 7C, 7E, 7F" is executed, all data on pages 7C, 7E, 7F are initialized. (Only an individual page cannot be initialized) Note 2: If the 7C, 7E, 7F page data has been initialized, the following adjustments need to be performed again. 1) Modification of 7C, 7E, 7F page data 2) HALL adjustment (1) (if all areas were initialized) 3) Angular velocity sensor sensitivity adjustment (if all areas were initialized) Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data 1 2 3 4 5 6 7 0 0 2 (72) 2 (72) 2 (72) 0 01 10 01 02 01 10 00 00 Perform "Modification of 7C, 7E, 7F Page Data". 01 07 2D Press PAUSE (Write) button. Check the data changes to "01". Press PAUSE (Write) button. Procedure 7C 00 to FF 7E 00 to FF 7F 00 to FF

2. Modification of 7C, 7E, 7F Page Data If the 7C, 7E, 7F page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Processing before Modification 7C, 7E, 7F page data: Order Page Address Data 1 2 3 0 0 3 01 10 71 01 00 01 Press PAUSE (Write) button. Procedure

Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages 7C, 7E, 7F, set data: 01 to page: 0, address: 10, and then select pages C, E, F. After the modification of data finished, return the data on page: 0, address: 10 to "00". 3) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 4) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 5) If all areas were initialized, check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification 7C, 7E, 7F page data: Order Page Address Data 1 2 3 4 5 6 0 0 3 3 2 2 01 10 70 70 00 01 29 29 Press PAUSE (Write) button. 01 00 10 Press PAUSE (Write) button. Check the data changes to "11". Procedure

HDR-HC9/HC9E_ADJ 6-29

3. 7C Page table Note 1: If reading/writing data on pages 7C, set data: 07 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 7C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 7C, 7E, 7F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 7C, 7E, 7F Page Data") Address 00 to 11 12 13 14 15 16, 17 18 19 1A to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

4. 7E Page table Note 1: If reading/writing data on pages 7E, set data: 07 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 7E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 7C, 7E, 7F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 7C, 7E, 7F Page Data") Address 00 to 16 17 18 to 50 51 52 53 54 to AA AB AC, AD AE AF to C3 C4 C5 C6 to EF F0 F1 to FF Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-30

5. 7F Page table Note 1: If reading/writing data on pages 7F, set data: 07 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 7F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing of 7C, 7E, 7F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 7C, 7E, 7F Page Data") Address 00 to 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10, 11 12 13 14 to FF 36 36 36 36 80 80 80 80 03 77 03 79 00 A3 00 83 80 80 80 80 03 77 03 79 00 A3 00 83 Fixed data-1 (Initialized data) Angular velocity sensor sensitive adj. Fixed data-1 (Initialized data) HALL adj. (1) Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

HDR-HC9/HC9E_ADJ 6-31

1-3.

CAMERA SYSTEM ADJUSTMENTS

Before perform the camera system adjustments, check that the specified values of "VIDEO SYSTEM ADJUSTMENTS" are satisfied. (Except Origin Oscillation Check") Check that the data of page: 0, address: 10 is "00". If not, select page: 0, address: 10, and set the data "00". 1. Origin Oscillation Check (CM-077 board) Check the frequency of the clock for synchronization. If deviated, the synchronization will be disrupted and the color will become inconsistent. Subject Measurement Point Measuring Instrument Specified value Not required Pin qh of CN6601 on CM-077 board Frequency counter f = 44505494 ± 895 Hz (HDR-HC9) f = 37125000 ± 745 Hz (HDR-HC9E)

2. HALL Adjustment RadarW Adjust the offset and gain to eliminate the output dispersion of the Hall sensor. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Not required Adjusting remote commander 7F 04 to 0F Data of page: 72 address: 03 is "00" Data of page: 72 address: 04 is "00"

Switch setting 1) POWER ............................................. CAMERA-TAPE mode Checking method: 1) Check that the frequency (f) satisfies the specified value.

Note 1: If reading/writing data on pages 72, 7F set data: 07 to page: 0, address: 10, and then select pages: 2, F. By this data setting, the pages 72, 7F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Perform this adjustment only when replacing the lens block. When the microprocessor, circuit etc. is damaged, don't perform this adjustment but check the steady shot operations only. Note 3: Perform the adjustment with the camcorder in horizontal state. Note 4: Do not move the set. Switch setting 1) POWER ............................................. CAMERA-TAPE mode Adjusting method: Order Page Address Data 1 2 3 0 0 2 (72) 2 (72) 2 (72) 2 (72) 01 10 01 01 07 97 Press PAUSE (Write) button. (Note 5) Wait for 4 seconds. 01 03 04 Check the data changes to "01". Check the data is "00". (Note 6) Check the data is "00". (Note 6). Procedure

CM-077 BOARD (SIDE B)

16
1

4
40

CN6601

5 6

Fig. 6-1-9
7

Note 5: The adjustment data will be automatically input to page: 7F, address: 04 to 07. Note 6: If the data is other than "00", perform readjustment. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 2 (72) 0 0 01 10 01 00 00 00 Turn off the power and turn on again. Shake the camcorder vertically and horizontally to check that the steady shot function operates normally. Procedure Press PAUSE (Write) button.

5

HDR-HC9/HC9E_ADJ 6-32

3. HALL/MR Adjustment RadarW For detecting the position of lens iris and ND filter, adjust the hall AMP gain and offset. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Not required Adjusting remote commander 69 (HALL) 6F (MR) D0 to D8 (HALL) 30, 40 to 4F (MR) Data of page: 6, address: 0C is "00" Note 1: If reading/writing data on pages 69, set data: 06 to page: 0, address: 10, and then select pages 9. By this data setting, the pages 69 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Perform the adjustment with the lens in horizontal state. Note 3: Perform "Flange Back Adjustment" after this adjustment. Note 4: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Switch setting 1) POWER ............................................. CAMERA-TAPE mode Adjusting method: Order Page Address Data 1 2 3 4 5 6 0 6 6 6 6 6 01 02 D0 01 02 0C 22 B1 Press PAUSE (Write) button. (Note 6) Check the data changes to "01". Check the data is "00". 01 Check the data is "00". (Note 5) Procedure

4. Differential Gain Adjustment RadarW Correct the dispersion of between the channels of CMOS imager. Subject Adjustment Page Adjustment Address Clear chart (All white) (Note 1) 6E 00 to B3

Note 1: Shoot the clear chart with the zoom TELE end. Note 2: If reading/writing data on pages 6E set data: 06 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 6E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHT SHOT .................................................................. OFF 3) ZOOM ..................................................................... TELE end 4) STEADY SHOT (Menu setting) ..................................... OFF 5) FOCUS (Menu setting) .......................................... MANUAL Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 11 6 02 0 6 6 6 6 6 6 6 6 01 02 2C 40 D0 D2 D3 D6 01 01 01 60 01 01 10 F5 Press PAUSE (Write) button. (Note 4) Wait for 30 seconds. Check the data changes to "01". 01 Check the data is "00". (Note 3) Procedure

Note 5: If not, select page: 6, address: 01, set data: 00, and press the PAUSE (Write) button. Note 6: The adjustment data will be automatically input to page: 69, address: D0 to D8. Note 7: The adjustment data will be automatically input to page: 6F, address: 30, 40 to 4F. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 5 6 6 6 0 02 01 01 00 00 6 6 01 01 00 25 Procedure Press PAUSE (Write) button. Press PAUSE (Write) button. Wait for 2 seconds. Check the data changes to "01". Press PAUSE (Write) button.

Note 3: If not, select page: 6, address: 01, set data: 00, and press PAUSE (Write) button. Note 4: The adjustment data will be automatically input to page: 6E, address: 00 to B3. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 6 6 6 0 01 40 2C 01 00 00 00 00 Procedure Press PAUSE (Write) button.

HDR-HC9/HC9E_ADJ 6-33

Ver. 1.1 2008.05
The changed portions from Ver. 1.0 are shown in blue. Flange Back and Zoom Key Adjustment RadarW (Using the minipattern box or flange back adjustment jig) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. 5. Subject Siemens star chart with ND filter for minipattern box (Note 1) or flange back adjustment jig Adjusting remote commander 6F 11, 20 to 3F Data of page: 6F, address: 2F is "00" to "09" Data of pege: 6, address: 0C is "00"

Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value

Preparation (Using the minipattern box) 1) The minipattern box is installed as shown in the following figure. Note 7: The attachment lenses are not used. 2) Install the minipattern box so that the distance between it and the front of lens of camera is less than 3 cm. 3) Make the height of minipattern box and the camera equal. 4) Check the output voltage of the regulated power supply is the specified voltage ± 0.01 Vdc. 5) Check that the center of Siemens star chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively. Specified voltage: The specified voltage varies according to the minipattern box, so adjustment the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camera

Note 1: Dark Siemens star chart. Note 2: Perform "HALL Adjustment", "HALL/MR Adjustment" and "Differential Gain Adjustment" before this adjustment. Note 3: Perform the adjustment with the lens in horizontal state. Note 4: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 5: Don't touch the zoom lever during adjustment. Note 6: After adjustment, if the focusing to a subject located at infinity failed, increase the illuminance of the chart and perform readjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHT SHOT .................................................................. OFF 3) COLOR SLOW S (Menu setting) ................................... OFF 4) REC FORMAT (Menu setting) ............................. HDV1080i

Regulated power supply Output voltage : Specified voltage ± 0.01 Vdc Output current : more than 3.5 A

Red (+) Black (­) Yellow (SENS +) White (SENS ­) Black (GND) Need not connected

Fig. 6-1-10
Preparation (Using the flange back adjustment jig) (Illuminance: 300 to 400 lux) 1) Install the flange back adjustment jig so that the distance between it and the front of lens of camera is less than 3 cm. 2) Make the height of flange back adjustment jig and the camera equal. 3) Check that the center of chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively.
Flange back adjustment jig Below 3 cm

Camera

Fig. 6-1-11

HDR-HC9/HC9E_ADJ 6-34

Adjusting method: Order Page Address Data 1 2 3 4 0 0 06 06 01 10 1C 1D 01 00 33 Set the following data 11: HDR-HC9 12: HDR-HC9E Set the following data 5 6 7 8 9 10 11 12 13 14 15 16 17 6 6 0 F (6F) 0 02 0C 10 2F 10 00 06 Check the data is "00" to "09". 6 01 27 06 6 6 6 6 1E 02 4D 64 01 40 04 13 Press PAUSE (Write) button. Wait for 2 seconds. Press PAUSE (Write) button. (Note 9) Wait for 10 seconds. Check the data changes to "01". Check the data is "00". BC: HDR-HC9 00: HDR-HC9E Check the data is "00". (Note 8) Procedure

Note 8: If not, select page: 6, address: 01,