Text preview for : SONY DSC-W80, W85 SECTION 6 ADJUSTMENTS AUTO-ADJ VER 1.4 2008.05 (9-852-194-55).pdf part of SONY DSC-W80 SONY DSC-W80, W85 DIGITAL STILL CAMERA. SECTION 6 ADJUSTMENTS AUTO-ADJ VERSION 1.4 2008.05 PART# (9-852-194-55)



Back to : SONY DSC-W80, W85 SECTION | Home

DSC-W80/W85
Ver. 1.4 2008.05
Revision History

SECTION 6 ADJUSTMENTS

Auto-ADJ

Link
Before starting adjustments
Adjusting items when replacing main parts and boards List of service tools

SERVICE MODE
APPLICATION FOR ADJUSTMENT (SeusEX) SERVICE MODE DATA BACKUP

CAMERA SECTION ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS ADJUSTMENT PROGRAM DESTINATION DATA WRITE USB SERIAL No. INPUT VIDEO SYSTEM ADJUSTMENTS CAMERA SYSTEM ADJUSTMENTS LCD SYSTEM ADJUSTMENTS ERROR

· Use this Service Manual together with the Automatic Adjustment Program (DSC-W80_W85 Auto-Adj Ver_1.4r05.exe).

DSC-W80/W85_ADJ
9-852-194-52

Sony EMCS Co.

2008E0500-1 © 2008.5 Published by Kohda TEC

TABLE OF CONTENTS
Section Title Page

6.

ADJUSTMENTS

Before Starting Adjustments ····················································· 6-1 1-1. Adjusting Items When Replacing Main Parts and Boards ···················································· 6-3 1-2. List of Service Tools ························································ 6-4 6-1. Camera Section Adjustments ··········································· 6-6 1-1. Preparations Before Adjustments ···································· 6-6 1-2. Adjustment Program ······················································ 6-13 1-3. Destination Data Write ·················································· 6-15 1-4. USB Serial No. Input ····················································· 6-17 1-5. Video System Adjustments ············································ 6-18 1-6. Camera System Adjustments ········································· 6-21 1-7. LCD System Adjustments ············································· 6-31 1-8. Error ··············································································· 6-33 6-2. Service Mode ································································· 6-35 2-1. Application for Adjustment (SeusEX) ·························· 6-35 2-2. Service Mode ································································· 6-36 2-3. Data Backup ·································································· 6-41

DSC-W80/W85_ADJ --2--

SECTION 6 ADJUSTMENTS
Before starting adjustments Method for Copying or Erasing the Data in Internal Memory (Internal Memory/Music)
The data can be copied/erased by the operations on the HOME screen. (When erasing the data, execute formatting the internal memory.) Note 1: When replacing the SY-173 board, erase the data in internal memory of the board before replacement. Note 2: When replacing the SY-173 board, execute formatting and initialize the internal memory after replacement.

Method for copying the data in internal memory
Copy
Copies all images in the internal memory to a "Memory Stick Duo".
1 Insert a "Memory Stick Duo" having 32 MB or larger capacity. 2 Select [Copy] with v/V/b/B on the control button, then press z. The message "All data in internal memory will be copied" appears. 3 Select [OK] with v, then press z. Copying starts.

To cancel the copying
Select [Cancel] in step 3, then press z.
· Use a fully charged battery pack. If you attempt to copy image files using a battery pack with little remaining charge, the battery pack may run out, causing copying to fail or possibly corrupting the data. · You cannot copy individual images. · The original images in the internal memory are retained even after copying. To delete the contents of the internal memory, remove the "Memory Stick Duo" after copying, then execute the [Format] command in [Internal Memory Tool]. · When you copy the data in the internal memory to the "Memory Stick Duo", all the data will be copied. You cannot choose a specific folder on the "Memory Stick Duo" as the destination for the data to be copied. . · Even if you copy data, a (Print order) mark is not copied

Method for formatting the internal memory
This item does not appear when a "Memory Stick Duo" is inserted in the camera.

Format
Formats the internal memory.
· Note that formatting irrevocably erases all data in the internal memory, including even protected images.

1 Select [Format] with v/V/b/B on the control button, then press z. The message "All data in internal memory will be erased" appears. 2 Select [OK] with v, then press z. The format is completed.

To cancel the formatting
Select [Cancel] in step 2, then press z.

DSC-W80/W85_ADJ 6-1

How to Write Data to Internal Memory
Usually, the camera has been set so as to disable the data writing from the PC to the internal memory of the camera. This setting must be changed temporarily when the data is to be written to the internal memory such as a case after the board replacement. To change the setting, use the write enable tool "WriteEnableTool.exe".

Data writing method
1) Connect the PC to the camera (USB mode: Mass Storage), and switch the driver to the "Sony Seus USB Driver". 2) Start the Write Enable Tool and the SeusEX. 3) Click the [Activate Write Enable Mode] button of the Write Enable Tool.

4) Upon completion of the setting change, the following message will be displayed.

5) Return the driver to the original one, and connect the PC to the camera (USB mode: Mass Storage). 6) Write the data read out into the PC to the internal memory of the camera. 7) Disconnect the PC from the camera, and turn off the camera. Note: By turning off the camera, the write enable setting is reset.

DSC-W80/W85_ADJ 6-2

1-1. Adjusting items when replacing main parts and boards
When replacing main parts and boards, adjust the items indicated by z in the following table. Note 1: When replacing the SY-173 board, erase the data in internal memory of the board before replacement. Note 2: When replacing the SY-173 board, execute formatting and initialize the internal memory after replacement.
Replaced parts Block replacement Mounted parts replacement Board replacement

CCD block assy (Including CD-701 flexible board and CCD imager)

(Timing gen., CCD signal process)

(AF illumination LED)

(PITCH, YAW sensor)

(Video amp.)

LCD unit

Adjusting item

Adjustment

SY-173 board

SY-173 board

SY-173 board

Destination Data Write USB Serial No. Input

Destination data write USB serial No. input Composit video level adj.

z z

VIDEO adjustment

Component out Y level adj. Component out Pb level adj. Component out Pr level adj.

z

z

CAMERA adjustment 1 CAMERA adjustment 2 CAMERA adjustment 3

Hall adj. Flange back adj. Flange back check F No. compensation Measure gain adj. Light value adj. Mechanical shutter adj.

z z z z z

z z z

CAMERA adjustment 4

AWB 3200K-5800K standard data input AWB 3200K-5800K check Color reproduction adj. & check CCD linearity check CCD white defect compensation check CCD black defect compensation check

z z

z

z

CAMERA adjustment 5 CAMERA adjustment 6 CAMERA adjustment 7 LCD adjustment

Strobe adj. Auto focus illumination check Angular velocity sensor sensitivity adj. V-COM adj. White Balance adj.

z z z z z

z z

z z

z z z z

Table 6-1-1

DSC-W80/W85_ADJ 6-3

SY-173 board

ST-160 board

ST-160 board

LCD block

Lens block

Flash unit

(COMPLETE) (Note 1, 2)

(COMPLETE)

SE502, SE501

LCD901

IC304

IC602

D002

1-2. List of service tools
· Oscilloscope · Color monitor

J-1

J-2 HASP key and application for adjustment (SeusEX) Personal computer (Note 1)

J-3

Contact our service headquarters of each area how to get the application for adjustment (SeusEX) and HASP key. J-5 Pattern box PTB-450 J-6082-200-A or Small pattern box PTB-1450 J-6082-557-A J-8 J-9 J-6

USB, A/V, DC IN cable for multi-use terminal 1-830-848-21

J-4

9 colors chart (Note 2) For PTB-1450: J-6082-562-A

USB cable 1-829-868-41

J-7 Clear chart For PTB-450: J-6080-621-A For PTB-1450: J-6082-560-A J-10

Minipattern box J-6082-353-B

Flange back adjustment jig J-6082-563-A

J-11

J-12

Siemens star chart J-6080-875-A

Background paper J-2501-130-A

AC power adaptor AC-LS5 1-479-284-51

Fig. 6-1-1
Note 1: Personal computer OS: Windows98/98SE/Me/2000/XP Home/XP Pro RAM: 256 MB or more recommended USB: 2.0 recommended (also compatible with 1.1) Two connectors are required. Note 2: In using the 9 colors chart on the pattern box PTB-450, adjust the chart size through the procedure shown below so that it matches to the pattern box PTB-450. 1) Prepare a woody board A of the thickness 5 mm, and paint it mat-black. 2) Fit the 9 colors chart in the woody board A, and secure the chart with a black tape, etc. to shield the light.
woody board A 360 mm 155 mm woody board A

135 mm 280 mm

9 colors chart

DSC-W80/W85_ADJ 6-4

J-13 Tripod Adaptor J-6082-577-A

J-14

J-15

Camera table J-6082-384-A

HD Station (CSS-HD1) (Note 3) A-1242-190-A

Fig. 6-1-2
Note 3: The HD Station must be modified. (Refer to "4. HD Station Modifying Procedure")

DSC-W80/W85_ADJ 6-5

6-1. CAMERA SECTION ADJUSTMENTS
1-1. PREPARATIONS BEFORE ADJUSTMENTS
L = About 11 cm Pattern box L

1-1-1. Preparations 1) Connect the equipment for adjustments according to Fig. 6-1-4. 2) Start up the application for adjustment (SeusEX).

Front of the lens Camera

Fig. 6-1-3

PC (The SeusEX must be installed in the PC.) OS: Windows 98/98SE/Me/2000/XP RAM: 256MB or more recommended USB: 2.0 recommended (also compatible with 1.1) Two connectors are required.

DISP SEL switch setting TV: Video/Camera System Adjustment CAMERA: LCD/Control System Adjustment

To Multi connector

HASP Key
AC power adaptor AC-LS5 (1-479-284-51) AC IN

Video system Adjustment (Composite video level adj.) Oscilloscope Terminated 75

To USB connector

Color monitor

Video (yellow)

USB, A/V, DC IN cable for multi-use terminal (1-830-848-21)

To DC IN jack

Audio (Black)

Fig. 6-1-4
Note: The set must be connected to the modified HD station when performing the "Component out (Y, Pb, Pr) level adjustment" in the "Video System Adjustment".

DSC-W80/W85_ADJ 6-6

· Connection diagram when "Component out (Y, Pb, Pr) level adjustment" in "Video System Adjustment" is performed.
Measurement Point (Component out (Y, Pb, Pr) level adj.)

Pr Pb Y

(COMPONENT OUT) Y (Green) Terminated 75 Pr (Red) Pb (Blue)

PC
To COMPONENT OUT To DC IN jack AC power adaptor AC IN To USB connector USB cable (1-829-868-41) OS: Windows 98/98SE/Me/2000/XP RAM: 256MB or more recommended USB: 2.0 recommended (also compatible with 1.1) Two connectors are required.

USB connector

HASP Key
To USB connector

Fig. 6-1-5
Note: For the USB connection, refer to "4. HD Station Modifying Procedure".

DSC-W80/W85_ADJ 6-7

1-1-2. Precautions 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments. 1. Mode dial ...................................................................... Auto Adjustment 2. ZOOM button ................................................................ WIDE end 3. Digital Zoom (Settings ­ Shooting Settings ­ Shooting Settings 1) .... Off 9 colors chart (Standard picture frame)
A B A C Green Yellow W14 A=B C= B 3

Cyan

White

Red

B

C14: Filter for AWB 5800K adjustment

C14

Blue

Magenta C

Effective picture frame Fig. a

A 2

Transparent window

(

LCD screen or under scan monitor TV picture

)
Fig. 6-1-6

Adjust the camera position and direction to obtain the LCD screen or the monitor TV display shown in Fig. a.

2. Subjects 1) 9 colors chart (Standard picture frame). When performing adjustments using the 9 colors chart, adjust the picture frame as shown in Fig. 6-1-6. (Standard picture frame) 2) Clear chart (Standard picture frame) Remove the 9 colors chart from the pattern box and insert a clear chart in its place. (Do not perform zoom operations during this time)

DSC-W80/W85_ADJ 6-8

3. Preparing the Flash Adjustment Box A dark room is required to provide an accurate flash adjustment. If it is not available, prepare the flash adjustment box as given below; 1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2) 400 mm woody board B (2) 370 mm woody board C (1) 700 mm

513 mm

513 mm

700 mm

730 mm

700 mm

Fig. 6-1-7
2) Apply black mat paint to one side of woody board A and B. 3) Attach background paper (J-2501-130-A) to woody board C. 4) Assemble so that the black sides and the background paper side of woody board A, B and C are internal. (Fig. 6-1-8)
woody board A

woody board B

woody board A

woody board B woody board C

Fig. 6-1-8

L = 50 cm

Flash adjustment box

Front of the lens

L

Camera

Background paper

Fig. 6-1-9

DSC-W80/W85_ADJ 6-9

4. HD Station Modifying Procedure The HD station must be modified to perform the "Component out (Y, Pb, Pr) level adjustment" in the "Video System Adjustment". Modify the HD station by the following steps. 1) Prepare the HD station and USB connector. Part No. HD station (Note) USB connector A-1242-190-A 1-794-962-11

Note: You may purchase the commercially available CSS-HD1. 2) Disassemble the HD station in the numerical order given in the following figure to remove the Connector board.
1 Pull the switch

Upper cabinet

4 Lower cabinet

3 Five screws 6 Connector board/ Multi board

5 Two screws

2 Two foot rubbers

Fig. 6-1-10
3) Mount the USB connector on the Connector board.

Connector board

Mount the USB connector.

Fig. 6-1-11

DSC-W80/W85_ADJ 6-10

4) Connect four lead wires between USB connector and Multi board. Wiring diagram when USB connector is added for modification CN105 (USB connector) VCC D­ D+ GND 1Pin 2Pin 3Pin 5Pin CN006 (No mount) 2Pin 4Pin 5Pin 6Pin
CN105 2 1 4 3 5

CONNECTOR BOARD (SIDE B)

MULTI BOARD (SIDE B)

1

5 2 4 6

21 CN006 22

Fig. 6-1-12

DSC-W80/W85_ADJ 6-11

5) Puncture the Upper cabinet to make a window for the USB connector as shown below.
Upper cabinet USB connector position

Puncture the Upper cabinet.

USB connector

Fig. 6-1-13
6) Assemble the HD station.

DSC-W80/W85_ADJ 6-12

Ver. 1.4 2008.05

1-2.

ADJUSTMENT PROGRAM

The DSC-W80_W85 is adjusted by the Automatic Adjustment Program. The Automatic Adjustment Program enters automatically via the SeusEX the adjustment operations that were formerly entered manually by the adjustment remote commander (some items may be adjusted by manual operation on the operation screen of the SeusEX). 1. 1) Precautions When Using Automatic Adjustment Program The Automatic Adjustment Program writes the adjustment results such as EVR data to the set through two-way communication with the camera via the SeusEX. Accordingly, the Automatic Adjustment Program must be used in the environment where the SeusEX operates. The Automatic Adjustment Program cannot be used when the SEUS or the SeusCam is running. Exit the SEUS or the SeusCam before using the Automatic Adjustment Program. The SeusEX must be already started on the PC when using the Automatic Adjustment Program. With the SeusEX not started, some adjustment items will take time in adjustment. The program run time may vary depending on the environment of the personal computer used.

3. Function of Each Button on Main Menu Screen When the Automatic Adjustment Program started, the Main Menu screen in Fig. 6-1-14 will appear. On this screen, select each adjustment section.

1 qa 2 4 5 6 7 8 9 0 3

2)

3)

4)

Fig. 6-1-14
1 [Connecting the Equipment] button A connection diagram of the equipment is displayed. 2 [CONNECT] button The mode of Camera is switched to the Adjustment Mode. When the Adjustment Mode has switched normally, the operation of the buttons 4 - 0 is enabled. 3 [END] button The mode of Camera is switched to the normal mode. When the normal mode has switched correctly, the Automatic Adjustment Program is finished. 4 [DESTINATION DATA WRITE] button The "DESTINATION DATA WRITE" screen appears. 5 [USB SERIAL N0. INPUT] button The "USB SERIAL No. INPUT" screen appears. 6 [VIDEO SYSTEM ADJUSTMENT] button The "VIDEO SYSTEM ADJUSTMENT" screen appears. 7 [CAMERA SYSTEM ADJUSTMENT] button The "CAMERA SYSTEM ADJUSTMENT" screen appears. 8 [LCD SYSTEM ADJUSTMENT] button The "LCD SYSTEM ADJUSTMENT" screen appears. 9 [SERVICE MODE] button The "SERVICE MODE" screen appears. 0 [DATA BACKUP] button The "DATA BACKUP" screen appears. qa This part indicates the version of Automatic Adjustment Program.

2. Start of Automatic Adjustment Program Double-click the application file (DSC-W80_W85 Auto-Adj Ver_1.4r05.exe), and the Automatic Adjustment Program will start.

DSC-W80/W85_ADJ 6-13

4. Setting of Adjustment Mode Before performing the adjustment, "Setting of Adjustment Mode" is required. [Setting method] 1) Connect the Camera to the PC with a USB cable, and turn on the power switch. 2) Start the Automatic Adjustment Program, and click the [Connect] button on the Main Menu screen. 3) When the following message is displayed, turn off and on again the power switch of the Camera. Note: Turning off and on the power switch causes the Camera to be switched to the Adjustment Mode. After the Camera restarted, click the [OK] button in the message window.

5. Release of Adjustment Mode To finish the adjustment, be sure to perform "Release of Adjustment Mode". [Releasing method] 1) Click the [END] button on the Main Menu screen. 2) When the following message is displayed, releasing of adjustment mode has completed. Click the [OK] button in the message window to exit the Automatic Adjustment Program. Note: The Camera switches to the normal mode by turning off and on the power switch. After the adjustment finished, turn off and on again the power switch of the Camera to confirm that the USB mode screen is displayed.

4) Upon successful completion of the settings in the Adjustment Mode, the operation of each button on the Main Menu screen is enabled.

DSC-W80/W85_ADJ 6-14

1-3.

DESTINATION DATA WRITE

Note: The DESTINATION DATA WRITE cannot be set with other than the Service board. Function of Each Button on Destination Data Write Screen Click the [DESTINATION DATA WRITE] button on the Main Menu screen, and the "DESTNATION DATA WRITE" screen in Fig. 61-15 will appear.
1

2. Destination Data Write [Writing method] 1) Select the model name with the Model Name List.

1.

2) Select the written destination with the Destination List.
4

2

3

Fig. 6-1-15
1 [To Menu] button The Main Menu screen comes back. 2 Model Name List Selects the model name. 3 Destination List Selects the written destination. 4 [Data Write] button Write the destination data to the camera. 3) Click the [Data Write] button.

4) The writing finishes when the following message is displayed.

DSC-W80/W85_ADJ 6-15

3.

Selectable Language Table
DSTINATION
SELECTABLE LANGUAGE

Portuguese

Norwegian

Traditional Chinese

Hungarian

Japanese

Simplified Chinese

Swedish

J1 JE3 U2 CA2 CEE2 CEE8 CEE9 CEH E14 E15 E32 E33 E37 AU2 HK1 CN1 KR2 AR2 BR1 CA2 CEE2 CEE8 CEE9 CEH E32 E37 AU2 KR2

J JE US CND AEP UK

z z a z a a a z a a a a a a a a z a a a a z a a a a z a a a a z a z a z a a z z a z a a a z a a a a a a z a a z a a a a a a a a z a a a a z a a a a z a a a a z a z a z a a a a a z: INITIAL LANGUAGE a a a a a a a a a a a a a a a a a a z a a a a a a a a a a a a a a a a a a a a a a a a a a a a z a a a a a z a a a a a a a a a a a a z a a a a a a a a a a z a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a

E

a a a a a a a a a a a a a z a a a a a a a

a a a a

a a a a

a a a a

a a a a

a a a a

a a a a

a a a a

a a a a

a a a a

AUS HK CH KR AR BR CND AEP UK E AUS KR

NTSC PAL NTSC NTSC PAL PAL PAL PAL PAL PAL PAL NTSC PAL PAL PAL PAL NTSC NTSC NTSC NTSC PAL PAL PAL PAL PAL PAL PAL NTSC

DSC-W85

DSC-W80

Table 6-1-2

DSC-W80/W85_ADJ 6-16

VIDEO OUT Default

AREA

Spanish

German

Russian

Persian

English

Korean

Turkish

Melayu

Finnish

French

Danish

Arabic

Czech

Greek

Polish

Italian

Dutch

Thai

1-4.

USB SERIAL No. INPUT

1.

The set is shipped with a unique ID (USB Serial No.) written in it. This ID has not been written in a new board for service, and therefore it must be entered after the board replacement. If original ID can be read from the board before replacement, read it from the board before replacement using the "SERIAL READ/ WRITE" screen, and then write it after replacement. If original ID cannot be read from the board before replacement, write the ID for service using the "MANUAL WRITE" screen. (The ID for service is different from the ID written when the set is shipped.) Enter the PRODUCT ID (last 5 characters of model name) and SERIAL No. into the screen and write them.

Function of Each Button on USB Serial No. Input Screen Click the [USB SERIAL No. INPUT] button on the Main Menu screen, and "USB SERIAL No. INPUT" screen in Fig. 6-1-16 will appear.
1

2

3 4 5

6 7

Fig. 6-1-16
1 [To Menu] button The Main menu screen comes back. 2 Display area The "PRODUCT ID", "SERIAL No." and "ASCII TRANSLATION" are displayed. For the "ASCII TRANSLATION", the last 5 characters of model name are displayed if the PRODUCT ID is set from the model name in the MANUAL WRITE. For the PRODUCT ID set in the factory, the model name is not displayed but "?" etc. will be displayed. 3 [Check Serial] button The USB SERIAL No. data is read from the camera and displayed in the display area. 4 [Read and Save] button The USB SERIAL No. data is read from the camera and saved in PC as a file. 5 [Load and Write] button The USB SERIAL No. data is loaded from the file saved in PC and written to the camera. 6 Input area Enter "PRODUCT ID" and "SERIAL No." when writing the ID for service. The "PRODUCT ID" is set from the last 5 characters of model name if the model name is selected. For the "SERIAL No.", read it from the label on the camera body and enter it. 7 [Write Manually] button The USB SERIAL No. data entered in the input area is written to the camera.

DSC-W80/W85_ADJ 6-17

1-5.
1-5-1.

VIDEO SYSTEM ADJUSTMENTS

Function of Each Button on Video System Adjustment Screen Click the [VIDEO SYSTEM ADJUSTMENT] button on the Main Menu screen, and the "VIDEO SYSTEM ADJUSTMENT" screen in Fig. 6-1-17 will appear.
1

2

3 4 5

Fig. 6-1-17
1 [To Menu] button The Main Menu screen comes back. 2 [Preparation] button Notes for adjustment or jigs used are displayed. 3 [Start] button Each adjustment "Composite Video Level Adjustment" or "Component out (Y, Pb, Pr) Level Adjustment" starts. 4 [Reboot] button When this button is clicked, the camera is rebooted. 5 [Release Data Setting] button The data setting at the adjustment is cancelled. During the data setting, the button color changes from "white" to "red". When the data setting is cancelled, the button color returns to "white". (Use this button when an error occurred in the video adjustment. If the adjustment completed successfully, the data setting is automatically cancelled and the button color returns to "white".) 1-5-2. Adjustment Items of VIDEO System Adjustment The adjustment items of video system adjustment are as listed in Table 6-1-3. The Automatic Adjustment Program executes the adjustment items if the VIDEO Adjustment Start button is clicked.

Button Name

Adjustment Composite Video Level Adj.

Measurement Point VIDEO terminal of USB, A/V, DC IN cable for multi-USB terminal (75 ohm terminated) R040 on Multi board (HD Station) R041 on Multi board (HD Station) R042 on Multi board (HD Station)

Measuring Instrument Oscilloscope Oscilloscope Oscilloscope Oscilloscope

Adjusting Address Block Page Address 11 11 11 11 60 60 60 60 06DE 06BF 06C0 06C1

VIDEO Adjustment

COMPONENT OUT Y Level Adj. COMPONENT OUT Pb Level Adj. COMPONENT OUT Pr Level Adj.

Table 6-1-3

DSC-W80/W85_ADJ 6-18

1-5-3. Adjusting Method 1. Composite Video Level Adjustment [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Video Adj. 2. Composite Video Level Adj. 3. VIDEO OUT Level Check 4. Release of Data Setting during Video Adj. [Adjusting method] 1) Click the [Start] button of the Composite Video Level Adj. 2) The Automatic Adjustment Program executes the "1. Data Setting during Video Adj.". 3) If "1. Data Setting during Video Adj." completed successfully, the following screen is displayed during the execution of "2. Composite Video Level Adj.". Using the [Up]/[Down] button on the screen, adjust so that the sync level of the video signals satisfies the specified value. After the adjustment, click the [End] button in the screen.

4) If the [End] button is clicked, "3. VIDEO OUT Level Check" will be executed. The following message and screen are displayed. Check that the sync signal level and burst level of the video signals satisfies the specified value, and click the [OK] button in the message.

5) If the [End] button is clicked, "2. Composite Video Level Adj." and "4. Release of Data Setting during Video Adj." will be executed. 6) Upon successful completion of all item the Composite Video Level Adjustment, the following message is displayed. Click the [OK] button.

DSC-W80/W85_ADJ 6-19

2. Component Video Level Adjustment [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Video Adj. 2. COMPONENT OUT Y Level Adj. 3. COMPONENT OUT Pb Level Adj. 4. COMPONENT OUT Pr Level Adj. 5. Release of Data Setting during Video Adj. [Adjusting method] 1) Click the [Start] button of the Component Video Level Adjustment. 2) The Automatic Adjustment Program executes the "1. Data Setting during Video Adj.". 3) If "1. Data Setting during Video Adj." completed successfully, the following screen is displayed during the execution of "2. COMPONENT OUT Y Level Adj.". Using the [Up]/[Down] button on the screen, adjust so that the Y signal level satisfies the specified value. After the adjustment, check that the sync level of the Y signals satisfies the specified value, and click the [End] button in the screen.

5) After that, the following screen is displayed during the execution of "4. COMPONENT OUT Pr Level Adj.". Using the [Up]/ [Down] button on the screen, adjust so that the Pr signal level satisfies the specified value. After the adjustment, check that the sync level of the Pr signals satisfies the specified value, and click the [End] button in the screen.

6) If the [End] button is clicked, the items from "2. COMPONENT OUT Y Level Adj." to "4. COMPONENT OUT Pr Level Adj." and "5. Release of Data Setting during Video Adj." will be executed. 7) Upon successful completion of all item the Component Video Level Adjustment, the following message is displayed. Click the [OK] button.

4) After that, the following screen is displayed during the execution of "3. COMPONENT OUT Pb Level Adj.". Using the [Up]/ [Down] button on the screen, adjust so that the Pb signal level satisfies the specified value. After the adjustment, check that the sync level of the Pb signals satisfies the specified value, and click the [End] button in the screen.

DSC-W80/W85_ADJ 6-20

1-6.
1-6-1.

CAMERA SYSTEM ADJUSTMENTS

Function of Each Button on Camera System Adjustment Screen Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main Menu screen, and the "CAMERA SYSTEM ADJUSTMENT" screen in Fig. 6-1-18 will appear.

1 2 3

3 2 4

5

Fig. 6-1-18
1 [To Menu] button The Main Menu screen comes back. 2 [Preparation] button Notes for adjustment or jigs used are displayed. 3 [Start] button Each adjustment from "Camera Adjustment 1" to "Camera Adjustment 7" starts. 4 [Reboot] button When this button is clicked, the camera is rebooted. 5 [Release Data Setting] button The data setting at the adjustment is cancelled. During the data setting, the button color changes from "white" to "red". When the data setting is cancelled, the button color returns to "white". (Use this button when an error occurred in the camera adjustment 1 to 6. If the adjustment completed successfully, the data setting is automatically cancelled and the button color returns to "white".)

DSC-W80/W85_ADJ 6-21

Ver. 1.4 2008.05

1-6-2.

Adjustment Items of Camera System Adjustment The adjustment items of camera system adjustment are as listed in Table 6-1-4. The Automatic Adjustment Program divides the adjustment items into seven, camera adjustment 1 to 7. Clicking either CAMERA Adjustment Start button allows the adjustment item which corresponds to that button to be executed. The adjustment conditions of the subject and filter vary depending on which item is adjusted. The Adjustment Program displays an instruction for the subject and filter as a message during the adjustment.

Button Name Hall Adj.

Adjustment

Subject

Block

CAMERA Adjustment 1

Not required Auto Orientation Adj. Siemens star chart with ND filter for minipattern box (Note 1) or Flange back adjustment jig Siemens star (1.0m from front the lens) (Illuminance: 200 to 400 lux)

Adjusting Address Page Address 0E00 to 0E04, 11 61 0E08, 0E09, 0E20 to 0E2F 11 61 0E0A to 0E0D 61 0F1C, 0F1D, 0F20 to 0F3F, 095A 0964 0961 0980, 0981, 0998, 0999 0C00 to 0C21, 0C24 to 0C49 0C50 to 0C57 0200 to 02FF, 0300 to 03FF, 0400 to 04FF, 0500 to 05FF 0000 to 00FF, 0100 to 01FF, 0400 to 04FF, 0500 to 05FF 09C2, 09C3, 0C72 to 0C75 0F10 to 0F15 0E10, 0E11

CAMERA Adjustment 2 Flange Back Adj.

11

CAMERA Adjustment 3 Flange Back Check F No. Compensation Measure Gain Adj. Light Value Adj. Mechanical Shutter Adj. AWB 3200K-5800K Standard Data Input AWB 3200K-5800K Check CAMERA Adjustment 4 Color Reproduction Adj. & Check CCD Linearity Check CCD White Defect Compensation Check

11

61 61 61 61 61 61 61

Clear chart (Standard picture frame)

11 11 11 11

9 color chart (Standard picture frame)

11 11

Clear chart (Standard picture frame) 11 61

CCD Black Defect Compensation Check CAMERA Adjustment 5 Strobe Adj. Flash adjustment box (50 cm)

11 11 11

61 61 61

CAMERA Adjustment 6 Auto Focus Illumination Check Flash adjustment box (50 cm) Angular Velocity Sensor CAMERA Adjustment 7 Sensitivity Adj.
Note 1: Dark Siemens star chart.

Not required

Table 6-1-4

DSC-W80/W85_ADJ 6-22

1-6-3. Adjusting Method 1. CAMERA Adjustment 1 Note: There is no magnetic substance within around 8 cm of the camera. [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Hall Adj. 3. Auto Orientation Adj. 4. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of CAMERA Adjustment 1. 2) The Automatic Adjustment Program executes the "1. Data Setting during Camera Adj.". 3) Upon successful completion of "1. Data Setting during Camera Adj.", the following message and screen are displayed. Set the camera in accordance with the message.

6) If the [OK] button is clicked, "3. Auto Orientation Adj." and "4. Release of Data Setting during Camera Adj." will be executed. 7) Upon successful completion of all items of the CAMERA Adjustment 1, the following message is displayed. Click the [OK] button.

Processing after Completing Adjustment: [Checking method] 1) [HOME screen] t [Settings] t [Shooting Settings] t [Shooting Settings 2] t Select [Auto Orientation] to "ON". 2) Shoot with the set in respective positions (a) to (c) shown below. 3) Check the pictures in the Playback mode to confirm that the pictures are rotated correctly.

(a)

4) If the [OK] button is clicked, "2. Hall Adj." will be executed. 5) Upon successful completion of "2. Hall Adj.", the following message and screen are displayed. Set the camera in accordance with the message.

(b)

(c)
Fig. 6-1-19

DSC-W80/W85_ADJ 6-23

Ver. 1.4 2008.05

2. CAMERA Adjustment 2 [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Flange Back Adj. 3. Release of Data Setting during Camera Adj. Preparation of Flange Back Adj. (Using the minipattern box) 1) The minipattern box is installed as shown in the following figure. Note 1: The attachment lenses are not used. 2) Install the minipattern box so that the distance between it and the front of lens of camera is less than 3 cm. 3) Make the height of minipattern box and the camera equal. 4) Check the output voltage of the regulated power supply is the specified voltage ± 0.01 Vdc. 5) Check that the center of Siemens star chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively. Specified voltage: The specified voltage varies according to the minipattern box, so adjustment the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camera

Preparation of Flange Back Adj. (Using the flange back adjustment jig) (Illuminance: about 300 lux) Note 2: When using the flange back adjustment jig, take care of the following points: · For the illumination, use a light source such as an incandescent lamp or inverter type fluorescent light free from flickering. · Do not make an adjustment in the environment where fluorescent lamp flickering occurs even if the illuminance can be ensured with the room illumination only. Use an incandescent lamp or inverter type fluorescent light at a place free from the influence of room illumination. 1) Install the flange back adjustment jig so that the distance between it and the front of lens of camera is less than 3 cm. 2) Make the height of flange back adjustment jig and the camera equal. 3) Check that the center of chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively.
Flange back adjustment jig Below 3 cm

Camera

Fig. 6-1-21

Regulated power supply Output voltage : Specified voltage ± 0.01 Vdc Output current : more than 3.5 A

Red (+) Black (­) Yellow (SENS +) White (SENS ­) Black (GND) Need not connected

Fig. 6-1-20

DSC-W80/W85_ADJ 6-24

Ver. 1.4 2008.05

[Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 2. 2) The Automatic Adjustment Program executes "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject by referring to "Preparation of Flange Back Adj.".

3. CAMERA Adjustment 3 [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Flange Back Check 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 3. 2) The Automatic Adjustment Program executes "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject in accordance with the message.

4) If the [OK] button is clicked, "2. Flange Back Adj." and "3. Release of Data Setting during Camera Adj." will be executed. 5) Upon successful completion of all items of the CAMERA Adjustment 2, the following message is displayed. Click the [OK] button.

4) Click the [OK] button is clicked, "2. Flange Back Check" is executed. The following messages are displayed, and then operate the camera to make a check in accordance with the messages.

5) Upon completion of "2. Flange Back Check", "3. Release of Data Setting during Camera Adj." is executed. 6) Upon successful completion of all items of the CAMERA Adjustment 3, the following message is displayed. Click the [OK] button.

DSC-W80/W85_ADJ 6-25

4. Picture Frame Setting (Standard Picture Frame) In the "CAMERA Adjustment 4", set the picture frame so as to attain the positions shown in the following figure when shooting the 9 colors chart. Check on the oscilloscope Measurement Point: Video terminal of USB, A/V, DC IN cable for multi-use terminal (75 terminated) 1. Horizontal period
A=B A B A

5. CAMERA Adjustment 4 [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Picture Frame Setting 3. F No. Compensation 4. Measure Gain Adj. 5. Light Value Adj. 6. Mechanical Shutter Adj. 7. AWB 3200K-5800K Standard Data Input 8. AWB 3200K-5800K Check 9. Color Reproduction Adj. & Check 10. CCD Linearity Check 11. CCD White Defect Compensation Check 12. CCD Black Defect Compensation Check 13. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 4. 2) The Automatic Adjustment Program executes the "1. Data Setting during Camera Adj.". 3) Upon successful completion of "1. Data Setting during Camera Adj.", "2. Picture Frame Setting" is executed. The following message is displayed, and then referring to Fig. 6-1-22 to Fig. 6-1-24, set the subject and click the [OK] button.

Fig. 6-1-22
2. Vertical period
C C= B 3 V B C

After that, the next message is displayed. Then, change the chart in accordance with the message.

Fig. 6-1-23
Check on the monitor TV or the LCD screen
A=B C= B 3 A C Green Yellow W14

C14: Filter for AWB 5800K adjustment A B

Cyan

White

Red

B

C14

Blue Magenta C

Effective picture frame

A 2 Transparent window

Fig. 6-1-24

DSC-W80/W85_ADJ 6-26

4) Click the [OK] button, and the items from "3. F No. Compensation" to "6. Mechanical Shutter Adj." will be executed. 5) Upon successful completion of "6. Mechanical Shutter Adj.", the following message is displayed. Change the chart in accordance with the message.

At this time, the following message is displayed, and click the [Yes] button if the check result display at the upper right of Color Reproduction Check screen is OK, or the [No] button if NG.

6) Click the [OK] button, and the "7. AWB 3200K-5800K Standard Data Input" and "8. AWB 3200K-5800K Check" will be executed. 7) After that, "9. Color Reproduction Adj. & Check" will be executed. Upon completion of adjustment, the check result is displayed on the Color Reproduction Check screen.

8) Upon successful completion of "9. Color Reproduction Adj. & Check", the following message is displayed. Change the chart in accordance with the message.

9) Click the [OK] button, and the items from "10. CCD Linearity Check" to "13. Release of Data Setting during Camera Adj." will be executed. 10) Upon successful completion of all items of the CAMERA Adjustment 4, the following message is displayed. Click the [OK] button.

DSC-W80/W85_ADJ 6-27

6. CAMERA Adjustment 5 Note: "CAMERA Adjustment 5" is available only once after the power is turned on. If the adjustment is retried, turn off the power and turn on again. [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Strobe Adj. 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of CAMERA Adjustment 5. 2) The Automatic Adjustment Program executes the "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject in accordance with the message. (For the Flash adjustment box, refer to "3. Preparing the Flash Adjustment Box" (see page 6-9).)

7. CAMERA Adjustment 6 [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Auto Focus Illumination Check 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of CAMERA Adjustment 6. 2) The Automatic Adjustment Program executes the "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject in accordance with the message. (For the Flash adjustment box, refer to "3. Preparing the Flash Adjustment Box" (see page 6-9).)

4) Press the [OK] button, and the "2. Strobe Adj." will be executed. 5) During execution of "2. Strobe Adj.", the following message is displayed. After checking the flashing of strobe light, click the [OK] button. (This message is displayed 2 times during execution of adjustment.)

4) Press the [OK] button, and the "2. Auto Focus Illumination Check" will be executed. 5) Upon successful completion of the "2. Auto Focus Illumination Check", the "3. Release of Data Setting during Camera Adj." will be executed successively. 6) Upon successful completion of all items of the CAMERA Adjustment 6, the following message is displayed. Click the [OK] button.

6) Upon successful completion of "2. Strobe Adj.", "3.Release of Data Setting during Camera Adj." is executed. 7) Upon successful completion of all items of the CAMERA Adjustment 5, the following message is displayed. Click the [OK] button.

DSC-W80/W85_ADJ 6-28

Ver. 1.4 2008.05

8. CAMERA Adjustment 7 Perform this adjustment only when replacing the angular velocity sensor or lens block. When the microprocessor, circuit etc. is damaged, don't perform this adjustment but check the operations only. 8-1. Precaution before adjustment Before adjustment, read the following data and record them. When the SY-173 board is replaced, read out the data before the replacement, and record them. Reading out method: 1) Read out the data in Block:11, Page:61, Address:0E10, and name this as Dp. 2) Read out the data in Block:11, Page:61, Address:0E11, and name this as Dy. Note: The previous data (Dp, Dy) can be read from the SY173 board and it can be saved in the PC as a file by using the Automatic Adjustment Program. (Refer to "84. Angular Velocity Sensor Sensitivity Adjustment") 8-2. Preparation when the angular velocity sensor or the SY-173 board is replaced Note down the sensitivity displayed on the angular velocity sensor of the repair parts. At this time, note down also to which board it was attached to. Be sure to check because if attached incorrectly, the screen will vibrate up and down or left and right during the steady shot operations. Precautions on the Parts Replacement The PITCH sensor and the YAW sensor are different parts. Precautions on Angular Velocity Sensor The sensor incorporates a precision oscillator. Handle it with care as if it dropped, the balance of oscillator will be disrupted and operations will not be performed properly. Adjustment Block Adjustment Page Adjustment Address 11 61 0E10, 0E11

Preparation: 1) Read the PITCH sensor (SY-173 board SE502) sensitivity written on repair parts, and named this as S502. 2) Read the YAW sensor (SY-173 board SE501) sensitivity written on repair parts, and named this as S501.

SY-173 BOARD (SIDE A)

1

4

SE501

YY

Note: The sensor sensitivity of SE501 and SE502 of the SY-173 board is written only repair parts.

How to read the sensitivity data of angular velocity sensor With the pins 1 and 2 of angular velocity sensor placed in the lower position, read the data value.

Description example :
For the sensor sensitivity value 60
4 3

DSC-W80/W85_ADJ 6-29

1 4
1

SE502

PP
3

2

PP:PITCH sensor sensitivity t S502 YY:YAW sensor sensitivity t S501

2

Fig. 6-1-25

6 0
2

Hand Writing

Fig. 6-1-26

3

Ver. 1.4 2008.05

8-3. Preparation when the lens is replaced Note down the PITCH/YAW data on the replacement lens for repair. Adjustment Block Adjustment Page Adjustment Address 11 61 0E10, 0E11

8-4. Angular Velocity Sensor Sensitivity Adjustment [Adjusting method] 1) Click the [Start] button of Camera Adjustment 7, and the following screen will appear.

Note: The PITCH/YAW data of lens is written only repair parts. Preparation: 1) Read the PITCH data written on repair parts, and named this as L1. 2) Read the YAW data written on repair parts, and named this as L 2.

PITCH/YAW Data

2)

X.XX / X.XX
3)

YAW data

t L2

PITCH data t L1

Fig. 6-1-27

4)

5)

6)

The buttons on this screen provide the following functions. [Read] button: Reads and displays the previous data (Dp, Dy) from the SY-173 board. [Save] button: Saves the previous data (Dp, Dy) in the PC as a file. [Load] button: Loads and displays the previous data (Dp, Dy) from the file saved in the PC. Note: The previous data (Dp, Dy) is saved with the file name "DSC_W80_W85_DpDyData.dat" in the same folder as the Automatic Adjustment Program. Input the previous data (Dp, Dy) into screen. If the previous data cannot be read, give a check to the checkbox at the lower left of the screen. Input the sensitivity of respective sensors (S501, S502) read at "Preparation" into the screen. If only either sensor was replaced, give a check to the checkbox for the sensor not replaced at the lower left of the screen. Input the PITCH/YAW data of lens (L1, L2) read at "Preparation" into the screen. If the lens was not replaced, give a check to the checkbox at the lower left of the screen. Note: In order to get the correct value for the adjustment, it is necessary to input a decimal point ("period" or "comma") as same format as windows setting because "Numeric Value Format" depend on the language. (F:123 456 789,00, GB:123,456,789.00, D:123.456.789,00) "Numeric Value Format" setting is available in "Control Panel"-"Regional and Language Options". Click the [OK] button, and the adjustment data is then calculated from the sensor sensitivity value and the calculation result is written to the memory in the camera. Upon successful completion of the data writing, the following screen will appear. Check that the steady shot function operates normally.

DSC-W80/W85_ADJ 6-30

1-7.
1-7-1.

LCD SYSTEM ADJUSTMENTS

Function of Each Button on LCD System Adjustment Screen Click the [LCD SYSTEM ADJUSTMENT] button on the Main Menu screen, and the "LCD SYSTEM ADJUSTMENT" screen in Fig. 6-1-28 will appear.
1

1-7-2. Adjustment Items of LCD System Adjustment The adjustment items of LCD system adjustment are as listed in Table 6-1-5. The Automatic Adjustment Program executes the adjustment items if the LCD Adjustment Start button is clicked. Button Name LCD Adjustment V-COM Adj. Adjusting Address Block 11 11 Page 60 60 Address 0301 0368, 0369

Adjustment White Balance Adj.

Table 6-1-5
2 3

Fig. 6-1-28
1 [To Menu] button The Main Menu screen comes back. 2 [Start] button "LCD Adjustment" starts. 3 [Reboot] button When this button is clicked, the camera is rebooted.

DSC-W80/W85_ADJ 6-31

1-7-3. Adjusting Method [Automatic Adjustment Program execution items and sequence] 1. Data Setting during LCD Adj. 2. V-COM Adj. 3. White Balance Adj. [Adjusting method] 1) Click the [Start] button of the LCD Adjustment. 2) The Automatic Adjustment Program executes "1. Data Setting during LCD Adj.". 3) Upon successful completion of the "1. Data Setting during LCD Adj.", the following screen is displayed during the execution of "2. V-COM Adj.". Using the [Up]/[Down] button on the screen, adjust so that the brightness of portions A and B on the LCD panel is equal. After the adjustment, click the [End] button in the screen.

5) Upon successful completion of all item the LCD Adjustment, the following message is displayed. Click the [OK] button.

4) If the [End] button is clicked, the following screen is displayed during the execution of "3. White Balance Adj.". Check that the LCD screen is not colored. If colored, using the [Up]/[Down] button on the screen, adjust so that the LCD screen is not colored. After the adjustment, click the [End] button in the screen.

DSC-W80/W85_ADJ 6-32

1-8.

ERROR

3.

Adjustment Time Out

In the case of an error during the execution of adjustment, the Automatic Adjustment Program interrupts the processing at that point, and displays an error message, and then terminates the program execution there. 1-8-1. Error Message When an error message is displayed, perform the remedy given below, and then retry adjustment. If the error message is displayed though the remedy was performed, the circuits will be faulty. Symptom 1. Connect Error, Adjust Control Error Cause Remedy
This part indicates the adjustment item in which an error occurred.

Adjustment does not finish within the specified time. · Adjustment conditions are wrong. · Data error exists in the camera. · Check that the conditions such as a subject are correct. · Reset the camera.

4. Symptom Cause USB communication with the set is abnormal. · USB cable is not inserted tightly. · Power supply is not installed correctly. · Communication with SeusEX is abnormal. · Disconnect the USB cable once, and then reconnect it tightly and check that the set is in "USB Mode". · Install the power supply correctly. · Start the SeusEX and click the [Connect] to check that the connection state is established.

Adjustment NG

Remedy

This part indicates the adjustment item in which an error occurred.

Symptom Cause Remedy

The adjusted data does not become the specified value. · Adjustment conditions are wrong. · Data error exists in the camera. · Check that the conditions such as a subject are correct. · Reset the camera.

2.

RESET the CAMERA and Try Again

Symptom Cause Remedy

The camera is not ready for adjustment. Data error exists in the camera. Reset the camera.

DSC-W80/W85_ADJ 6-33

5.

Data Save Error

1-8-2. Precautions When an Error Occurred The Automatic Adjustment Program sets the data for adjustment before the adjustment starts. Accordingly, if the adjustment terminates by an error, the data during the adjustment may be left in the camera. Note 1: With this data left in the camera, the camera will not operate normally. In this case, the [Release Data Setting] button is displayed in "red" on the screen as shown figures below. Click the [Release Data Setting] button to cancel the data setting. When the data setting is cancelled, the button color becomes "white". Note 2: When "Data Save Error" occurred, the [Release Data Setting] button is displayed in "white". To cancel the data setting, perform it on the SeusEX Operation screen. How to cancel the data setting is displayed in the error message. Video System Adjustment screen

How to cancel the data setting during adjustment is display here.

Symptom Cause

data cannot be saved normally. (The data setting during adjustment cannot be cancelled) · Data writing to the flash memory failed. · Connection is faulty. · Power supply is not installed correctly. · On the SeusEX Operation screen, [Set] the data to the pages and addresses displayed in the message, and [Save] them. (Cancel manually the data setting during adjustment.) · Check the connection. · Install the power supply correctly.

Remedy

Camera System Adjustment screen

DSC-W80/W85_ADJ 6-34

6-2. SERVICE MODE
2-1. APPLICATION FOR ADJUSTMENT (SeusEX)
The adjustment software (SeusEX) can change operational coefficients of signal processing, EVR data, etc. same as the adjustment remote commander. The SeusEX performs two-way communication between PC and camera using the USB terminal. The twoway communication result data can be written in the nonvolatile memory. 1. 1) 2) 3) 4) Connection Connect the HASP key to the USB terminal of the PC. Connect the PC and camera with the USB cable. Start the SeusEX on the PC. Click [Connect] on the SeusEX screen. If the connection is normal, the SeusEX screen will be as shown in Fig. 6-2-1, indicating the "connected" state. Note: The SeusEX will go in "disconnect" state, if the camera is turned off (for instance, by resetting the set). In such a case, click [Connect] on the SeusEX screen to restore the "connected" state.

2. Operation · Block change To change the block, click [Block] on the SeusEX screen and enter the block to be changed. The block is displayed in hexadecimal notation. · Page change To change the page, click [Page] on the SeusEX screen and enter the page to be changed. The page is displayed in hexadecimal notation. · Address change To change the address, click [Address] on the SeusEX screen and enter the address to be changed. The address is displayed in hexadecimal notation. · Data change To change the data, click [Set] on the SeusEX screen and enter the data. The data is displayed in hexadecimal notation. This operation does not write the data to the nonvolatile memory. · Data writing To write the data to the EEPROM, click [Write] on the SeusEX screen and enter the data value to be written. To write the data to the flash memory, change the data value using the [Set] on the SeusEX screen and then click [Save] to save the data. · Data reading The data displayed on the SeusEX screen are the data values at the time when the pages and addresses were set, and they are not updated automatically. To check the data change, click [Read] on the SeusEX screen and update the displayed data.

Fig. 6-2-1

DSC-W80/W85_ADJ 6-35

2-2.

SERVICE MODE

1. Function of Each Button on Service Mode Screen Click the [SERVICE MODE] button on the Main Menu screen, and the "SERVICE MODE" screen in Fig. 6-2-2 will appear.
1

2. Switch Check Click the [Switch Check] button on the SERVICE MODE screen, and the "SWITCH CHECK" screen will appear.

2

4 5

3

Fig. 6-2-2
1 [To Menu] button The Main Menu screen comes back. 2 [Switch Check] button "SWITCH CHECK" screen appears. 3 [LED Check] button "LED CHECK" screen appears. 4 [Record Data] button "RECORD DATA" screen appears. 5 [Aging] button "AGING" screen appears.

Using method: Click the [Start] button, and the switch check will start. During execution of switch check, the pressed switch is displayed in orange. Also, once the switch was pressed, its name characters change to blue in color.

DSC-W80/W85_ADJ 6-36

Ver. 1.4 2008.05

3. LED Check Click the [LED Check] button on the SERVICE MODE screen, and the "LED CHECK" screen will appear.

4. Record Data Click the [Record Data] button on the SERVICE MODE screen, and the "RECORD DATA" screen will appear.

The record data such as Lifetime counter is displayed. Initializing method: Click the [Clear Shot Count] button on the screen, and the Lifetime Count data will be initialized. Using method: LED ON or OFF can be controlled with [LED ON] or [LED OFF] button on the screen.

DSC-W80/W85_ADJ 6-37

5. Aging On the AGING screen, various types of aging can be executed. Select the type of aging to be executed with the Aging Mode Select buttons.
Aging Mode Select button

(1) 10MODE In the 10MODE, perform continuous recording in accordance with the CIPA Standard. When the 10MODE starts, the following operation is repeated until the battery end. 1) The zoom moves to the TELE end. 2) The camera records a still picture with a strobe light flashed at the maximum level. 3) The camera stands by for the time (sec.) set to the "Rec Interval". 4) The zoom moves to the WIDE end. 5) The camera records a still picture without flashing a strobe light. 6) The camera stands by for the time (sec.) set to the "Rec Interval". 7) Each time 10 still pictures are recorded, the power is turned off, and after the time (min.) set to the "Power Off Interval", the power is turned on again. At the start of 10MODE, the counter in the camera is initialized. This counter counts the number of recording times during the execution of 10MODE, and it holds the counts even during the power off.

Supply the power not from an AC adapter but from the fully charged battery and execute the aging until the battery end, so that its battery use time and how many pictures the camera can record/play back can be checked. During the execution of aging, the camera automatically repeats recording/playback. During the recording, if the recording memory capacity becomes full, its memory is automatically formatted. Accordingly, when executing the aging, insert the Memory Stick into the camera and set the Memory Stick as default media. [Preparation] For the aging, set the camera as follows: Switch setting: 1) Flash button ...................................................................... Auto Home Items 1) Shooting ....................................................... Auto Adjustment 2) AF Mode (Settings ­ Shooting Settings ­ Shooting Settings 1) ..... Single

DSC-W80/W85_ADJ 6-38

10MODE screen and functions of each item

(2) AGING_REC In the AGING_REC mode, still pictures are continuously recorded at the interval (sec.) set to the "Rec Interval". At the start of AGING_REC, the counter in the camera is initialized. This counter counts the number of recording times during the execution of AGING_REC, and it holds the counts even during the power off.
4 5

2 3 1

AGING_REC screen and functions of each item

6

7
2 3 4

1 [Preparation] button Notes for aging is displayed. 2 Rec Interval setting and display The setting of recording interval (sec.) is displayed. The setting can be changed by entering a numeric value in this field.

1

5

6

3 Power Off Interval setting and display The setting of power off interval (min.) is displayed. The setting can be changed by entering a numeric value in this field. 4 [START] button The settings of parameters specified by the Rec Interval and Power Off Interval for execution of 10MODE are sent to the camera. The 10MODE starts when the camera power is turned off once and then on again. The settings for execution of 10MODE are held until the camera detects the battery end. They cannot be reset by the power off or RESET button. To interrupt the 10MODE, use the [STOP] button. 5 [STOP] button The settings for execution of 10MODE are reset. 6 [GET] button After the 10MODE was executed, the number of recording times is got from the counter in the camera. The result is displayed in the "Count" display field. 7 Count display The number of recording times got by the [GET] button is displayed.

1 [Preparation] button Notes for aging is displayed. 2 Rec Interval setting and display The setting of recording interval (sec.) is displayed. The setting can be changed by entering a numeric value in this field. 3 [START] button The AGING_REC starts. In the AGING_REC mode, the aging starts immediately when the [START] button is clicked. At the battery end, the AGING_REC stops. To interrupt the AGING_REC, use the [STOP] button, though the AGING_REC stops also by the power off or RESET button. 4 [STOP] button The AGING_REC stops. 5 [GET] button After the AGING_REC was executed, the number of recording times is got from the counter in the camera. The result is displayed in the "Count" display field. 6 Count display The number of recording times got by the [GET] button is displayed.

DSC-W80/W85_ADJ 6-39

(3) AGING_MREC In the AGING_MREC mode, motion pictures are continuously recorded for the time (sec.) set to the "Rec Time" at the interval (sec.) set to the "Rec Interval". At the start of AGING_MREC, the counter in the camera is initialized. This counter counts the number of recording times during the execution of AGING_MREC, and it holds the counts even during the power off. AGING_MREC screen and functions of each item

(4) AGING_PB In the AGING_PB mode, pictures are continuously played back at the interval (sec.) set to the "Play Back Interval". At the start of AGING_PB, the counter in the camera is initialized. This counter counts the number of play back times during the execution of AGING_PB, and it holds the counts even during the power off. AGING_PB screen and functions of each item

2
2 3 1 5 4

3 4

1

5
6

6
7

1 [Preparation] button Notes for aging is displayed. 2 Rec Time setting and display The setting of recording time (sec.) is displayed. The setting can be changed by entering a numeric value in this field. 3 Rec Interval setting and display The setting of recording interval (sec.) is displayed. The setting can be changed by entering a numeric value in this field. 4 [START] button The AGING_MREC starts. In the AGING_MREC mode, the aging starts immediately when the [START] button is clicked. At the battery end, the AGING_MREC stops. To interrupt the AGING_MREC, use the [STOP] button, though the AGING_MREC stops also by the power off or RESET button. 5 [STOP] button The AGING_MREC stops. 6 [GET] button After the AGING_MREC was executed, the number of recording times is got from the counter in the camera. The result is displayed in the "Count" display field. 7 Count display The number of recording times got by the [GET] button is displayed.

1 [Preparation] button Notes for aging is displayed. 2 Play Back Interval setting and display The setting of play back interval (sec.) is displayed. The setting can be changed by entering a numeric value in this field. 3 [START] button The AGING_PB starts. In the AGING_PB mode, the aging starts immediately when the [START] button is clicked. At the battery end, the AGING_PB stops. To interrupt the AGING_PB, use the [STOP] button, though the AGING_PB stops also by the power off or RESET button. 4 [STOP] button The AGING_PB stops. 5 [GET] button After the AGING_PB was executed, the number of play back times is got from the counter in the camera. The result is displayed in the "Count" display field. 6 Count display The number of play back times got by the [GET] button is displayed.

DSC-W80/W85_ADJ 6-40

2-3.

DATA BACKUP

With the "DATA BACKUP", the adjustment data in the camera can be backed up in the PC as a file. The adjustment data that can be backed up are as follows. System Control Section: 1) Video System Adjustments 2) LCD System Adjustments Camera Control Section: 1) Camera System Adjustments

1. Function of Each Button on Data Backup Screen Click the [DATA BACKUP] button on the Main Menu screen, and the "DATA BACKUP" screen in Fig. 6-2-3 will appear.
1

2 3

Fig. 6-2-3
1 [To Menu] button The Main Menu screen comes back. 2 [Data Read and Save] button Read the adjustment data from the camera and save them in PC as a file. 3 [Data Load and Write] button Load the adjustment data from the file saved in PC and write them to the camera.

DSC-W80/W85_ADJ 6-41E 6-41

Reverse

985219455.pdf

Revision History
Ver. 1.0 1.1 Date 2007.03 2007.04 History Official Release Supplement-1 (S1 DI07-003) Contents -- · Change of Automatic Adjustment Program · Addition of [Read], [Save], and [Load] buttons to Angular Velocity Sensitivity Adjustment · Addition of AF Illuminator as a Controllable LED to LED Check · Change of Automatic Adjustment Program · Change of Automatic Adjustment Program Replace the previously issued SERVICE MANUAL 9-852-194-52 with this Manual. · Change of Automatic Adjustment Program Version of Automatic Adjustment Program has been changed from Ver_1.3r04 into Ver_1.4r05. · Correction of adjustment condition · Addition of [Read], [Save], and [Load] buttons to Angular Velocity Sensitivity Adjustment · Note is added to alert the user when a decimal point (period or comma) is input to "Angular Velocity Sensor Sensitivity Adjustment" · Addition of AF Illuminator as a Controllable LED to LED Check S.M. revised: Page 6-13, Page 6-22, Page 6-24, Page 6-25, Page 6-29, Page 6-30, Page 6-37 Replace the SUPPLEMENT-1, SUPPLEMENT-2 and SUPPLEMENT-3 with the REVISED-1. Please discard the SUPPLEMENT-1, SUPPLEMENT-2 and SUPPLEMENT-3. S.M. Rev. issued -- Yes

1.2 1.3 1.4

2007.05 2007.05 2008.05

Supplement-2 (S2 DI07-010) Supplement-3 (S3 DI07-015) Revised-1 (A1 DI08-029)

Yes Yes Yes

DSC-W80/W85_ADJ