Text preview for : Linn-LK1 preamp.pdf part of Linn LK1 preamp



Back to : Linn-LK1 preamp.pdf | Home

20th August 1999

LK1 Service Manual

LK1 PreAmplifier Service Manual
CONTENTS
INTRODUCTION .................................................................................................................................... 2 ABOUT THIS MANUAL .............................................................................................................................. 2 R ETAILER & D ISTRIBUTOR OBLIGATIONS ................................................................................................... 2 SPARE PARTS AVAILABILITY AND LK1 REPAIR ............................................................................................ 2 HOW TO USE THIS MANUAL ...................................................................................................................... 2 INSTALLATION ..................................................................................................................................... 3 IMPORTANT SAFETY INFORMATION............................................................................................................ 3 INSTALLATION INSTRUCTIONS ................................................................................................................... 3 PLACEMENT.......................................................................................................................................... 3 POWER-UP PROBLEMS........................................................................................................................ 5 POWER UP PROBLEMS ............................................................................................................................ 5 FUSE BLOWING ...................................................................................................................................... 6 DISPLAY & CONTROL PROBLEMS....................................................................................................... 7 GENERAL D ISPLAY & CONTROL PROBLEMS ................................................................................................ 7 R EMOTE CONTROL PROBLEMS ................................................................................................................ 9 CONTROL VIA FRONT PANEL ...................................................................................................................10 AMPLIFIER PROBLEMS .......................................................................................................................11 AUDIO (L ISTEN) OUTPUT ........................................................................................................................11 TAPE ( RECORD) OUTPUT .......................................................................................................................13

Page1

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Introduction
About this manual
This manual is designed to help you as a Linn Retailer or Distributor to repair as many LK1 faults at your repair centre as is practical and so provide the best possible service for your customer should a problem arise. If you have any suggestions or comments regarding this manual, please contact Paul O'Neill at Linn Products Ltd: By E-mail [email protected] By Phone ++44 (0) 141 303 5005 By Fax ++44 (0) 141 644 4262 Marked for attention of Paul O'Neill

Retailer & Distributor Obligations
Linn Specialist Retailers or Distributors are obliged to carry out the repairs in this manual under the terms of the contract & warranty agreements. You should return a faulty product to Linn for repair, only if the fault is not covered in this Service Manual. If a product, which is under warranty, is returned to Linn for repair and the fault is covered in the service manual, Linn may levy a charge and this charge should not be passed to the customer.

Spare Parts Availability and LK1 repair
Please note that the LK1 has been obsolete for some considerable time now and as such, we cannot guarantee the supply of spare parts ­ many are simply no longer available. Some part numbers are listed throughout this manual, but these are provided for information only and this does not imply that these parts will be available should you request them. Linn guarantee that we will service a product until 5 years after the final build. We take this obligation very seriously and also go much further. Beyond this date, we will repair any Linn product that we possibly can, where it is within our power to do so. However, due to the difficulty with the availability of spare parts, as explained above, it is occasionally not possible to repair a product or supply parts for repair, as the necessary parts are not available and can no longer be sourced.

How to use this manual
The main body of this manual, the fault table, is designed to be as quick and simple as possible to use when you are confronted with a faulty product and so it is arranged by fault symptom as the symptom is usually all that you will know about the fault. If you are unsure about the meaning of any words or phrases, look in the Glossary. (accessible via Linfo Website - Product Information) Before embarking on any Service work, you should read the Service Procedures section (accessible via Linfo Website - Product Information), as there are certain procedures that must be followed in order to ensure the problem is resolved quickly and permanently Table of contents & fault symptoms Look firstly at the table of contents and find the category that covers the symptom you are seeing, then look down the list of faults in that section until you find the symptom or symptoms that best describe the problem. Circumstances Then simply follow the table along ­ the table specifies circumstances surrounding the fault symptom ­ e.g. whether the fault is likely to be intermittent or constant, if the fault only occurs within a range of serial numbers etc. Page2 Contents
Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Possible causes The next column details possible causes ­ this is effectively the most important section, probably the main reason you are looking at this manual at all. There may be several possible causes for the symptom you have ­ it is worth checking out all of these (and bear in mind that there may be more than one fault). For some faults, simple checks are detailed that you can use to rule out the problem without replacing any parts, whereas for other faults, the simplest way to rule out the problem is to replace the component(s) listed Cure Quite simply the action that you must take to cure the problem.

Installation
Important Safety Information
Mains connections This appliance must be earthed ­ both for Safety and functional reasons. Lethal Voltages Inside the LK1, lethal voltages are present, although normally these are inaccessible inside the transformer casing and at the mains switch (which is insulated with heatshrink sleeving.) If the mains switch is properly insulated, none of the wires to/from it are damaged and the transformer casing is closed, the LK1 is quite safe to work on while powered up as only low voltages are found on the circuit boards (maximum 38Vac and 22V dc)

Installation Instructions
Important ­ the LK1 Inverts the phase of the signal to the power amp, therefore to achieve absolute phase, connect the positive output of the power amp to the negative (black) loudspeaker terminal and the negative output to the positive (red) loudspeaker terminal. If, however, you use a speaker switching box or a headphone adaptor box however, these must be wired IN PHASE or damage to the power amp, headphones etc can result.

Placement
Location & Environment Do not locate near electronic products that may transmit RF, such as microcomputers, fax machines, TVs etc, or connect them to the same mains socket as these devices. Also avoid close contact with the mains or signal leads of such products ­ careful routing of the cable may be required. Avoid locations where direct sunlight can shine on the display as sunlight (even diffused sunlight) is a strong source of infra-red light & this causes problems with the unit's remote control circuitry. Avoid certain types of artificial lighting, such as low energy bulbs, fluorescent light etc, as these emit strong infra-red patterns that can lock up the LK1 control functions. Although the LK1 can usually be stacked along with other products with no problem, it is better if possible to keep it apart from other products to prevent its operation being adversely affected by the heat and strong electrical field emitted by some products. Avoid locations that have high humidity or the chance of the unit getting wet. Avoid locations where there is a lot of dust.

Page3 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Handling & general maintenance. Always handle the LK1 with great care. Always turn off the LK1 and any Power Amps connected to it before connecting or disconnecting any plugs to/from the sockets at the back of the unit. Wait at least 10 seconds after switching off the power amps before unplugging from the back of the LK1 to avoid damage to the speakers. If you are carrying out any work on the LK1 with its' sleeve removed, ALWAYS take anti-static precautions as tiny static discharges from your body, which you may be completely unaware of, can damage electronic circuitry and cause major problems. Anti-static earth mats & wrist straps must be used when handling any of the circuit boards or any spare parts.

Page4 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Power-up problems
Power up problems
Symptom Won't power up. Display dead & no function Circumstances Constant Possible Cause(s) Fuse blown in unit and/or in mains plug. Cure Replace fuse(s) with correct value & type. Fuse in mains lead should be 5A. Fuse in LK1 should be "Slow Blow" ­ look for a `T' before the rating on the fuse. Correct types are: 110/115V - T300mA antisurge 220/240V - T200mA antisurge Replace faulty mains lead.

Won't power up Power LED dead, no display & no function Display dies intermittently & unit stops working for a while. Doesn't power up or Powers up (display LED lit) but no function.

May be intermittent

Mains lead faulty

At any time

May be intermittent

Mains voltage dropping too low for LK1 to function correctly (known as `Brown outs' as these voltage drops also sometimes cause the house lights to dim.) Wrong mains voltage for LK1 type ­ mains voltage is too low. (e.g. 240V LK1 being used with 115V mains supply.)

Consult an electrician or your power company.

Doesn't power up or Powers up (display LED lit) but no function.

May be intermittent

One of the power supplies is dead or at an incorrect voltage level. Power supplies can be checked at the points listed below: +15V - U10 (regulator) output ­ middle leg. -15V - Q78 emitter (square pad) +Vref - U9 pin 7 -Vref - U9 pin 8 +8V - Q77 emitter (square pad)

Check voltage rating at rear of LK1. If wrong, transformer will require replacement. Correct part numbers are: MCAS 002/100 for 100V mains MCAS 002/115 for 115V mains MCAS 002/220 for 220V mains MCAS 002/240 for 240V mains Our stock of these transformers is very limited, so it may not be possible to supply the part you require. Cannot suggest a simple fix as some fault finding is required to trace the cause of the fault. See PCAS 001 Circuit Diagram (accessible via Linfo Website Product Information)

Page5 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Fuse blowing
Symptom Fuse blowing Circumstances May be intermittent Possible Cause(s) Wrong type of fuse fitted Cure Replace fuse(s) with correct value & type. Fuse in mains lead should be 5A. Fuse in LK1 should be "Slow Blow" ­ look for a `T' before the rating on the fuse. Correct types are: 110/115V - T300mA antisurge 220/240V - T200mA antisurge Consult an electrician or your power company. Check voltage rating at rear of LK1. If wrong, transformer will require replacement. Correct part numbers are: MCAS 002/100 for 100V mains MCAS 002/115 for 115V mains MCAS 002/220 for 220V mains MCAS 002/240 for 240V mains Our stock of these transformers is very limited, so it may not be possible to supply the part you require. Replace transformer. Correct part numbers are: MCAS 002/100 for 100V mains MCAS 002/115 for 115V mains MCAS 002/220 for 220V mains MCAS 002/240 for 240V mains Our stock of these transformers is very limited, so it may not be possible to supply the part you require. Replace D3 ­ Linn part no: MISS 002 See Introduction to Fault Finding section (accessible via Linfo Website - Product Information) for tips on tracing the fault. Also see circuit diagrams.

Fuse blowing Fuse blowing

May be intermittent Constant

Mains surges Wrong mains voltage for LK1 voltage setting - mains voltage is too high, e.g. a 115V LK1 connected to 230V mains.

Fuse blowing

May be intermittent but usually constant

Fuse blowing

Constant

Fuse blowing

Constant

Transformer faulty. To check if it is definitely the transformer, power down the unit, replace fuse, disconnect the transformer output from the Main board and power up. If the transformer IS the cause, the fuse will continue to blow. If the fuse remains intact, the fault is more likely to be on the Main board. Bridge rectifier ­ D3 on main board faulty (probably internally short circuit). Fault inside LK1, e.g. short circuit or similar.

Page6 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Display & Control problems
General Display & Control problems
Symptom Display dead or locked up. Flashing lights on display (sometimes known as `Disco lights' or `Christmas tree lights') LK1 will not function. Flashing lights on display (sometimes known as `Disco lights' or `Christmas tree lights') LK1 will not function. Circumstances Possibly intermittent Sometimes intermittent ­ may start doing this occasionally and then become more & more frequent. Symptoms may vary. Ensure that the above `Flashing light' fault (C12) has been ruled out. Sometimes intermittent ­ may start doing this occasionally and then become more & more frequent. Symptoms may vary. Ensure that the `Flashing light' fault (C12) above has been ruled out. Sometimes intermittent ­ may start doing this occasionally and then become more & more frequent. Symptoms may vary. Possible Cause(s) Unit not powering up correctly. C12 on control board faulty Cure See `Power up problems' section above Replace C12 ­ Linn part no: CAP 022

U9 (EEPROM) on control board faulty.

Flashing lights on display (sometimes known as `Disco lights' or `Christmas tree lights') LK1 will not function.

U7 and U8 on control board faulty.

Please Note U9 is unlikely to be the cause of this fault (perhaps a 1 in 50 chance) but is easy to rule out IF you have another LK1 or a control board or a spare U9 that you can try in the faulty product. If you do not have the part available, ignore U9. Linn part no: IC 016 (ensure U9 is programmed ­ a programmed U9 will have its window covered with a sticker that will normally read `MK3') Replace U7 & U8 ­ Linn part no: IC 015 for both parts.

Page7 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Display locked up ­ no function and no sources can be selected ­ input LEDs will not illuminate when input selection button is pressed.

Occurred after unit was switched off and then on again.

Battery faulty ­ if the battery is dead and the unit is switched off, the unit loses its memory. On most units, when this happens the unit functions okay afterwards but loses memory. On some units, however the display locks up and must be reactivated.

Display locked up ­ probably one, two or more LEDs on front panel constantly lit. No function.

Probably constant

Display dead or locked up. May have occasional `Disco Lights' Display locked up ­ amp will not function, perhaps one or two display LEDs permanently lit. May have occasional `Disco Lights' Display dead or locked up.

May be intermittent and symptoms may vary

Control board requires upgrade. Check for the following on control board: Is a Pot (variable resistor) fitted at location VR1? Is a capacitor fitted at C16? Does the EEPROM (U9) have MK3 written on it? If the answer is yes to any of these questions, the control board requires upgraded. Battery has leaked fluid onto control board, damaging components in that vicinity

To re-activate the display, press and hold one of the input selection buttons for about 5 seconds. Once the display is reactivated it will stay active and work as normal until the unit is switched off and then this must be repeated. To fix permanently, replace backup battery (BATT 1 on control board) and then re-activate the display. See LK1 Control Board Upgrade sheet (accessible via Linfo Website - Product Information)

Probably constant Symptoms may vary

U7, U8 or C12 on control board faulty.

Remove battery, clean board, replace any components that have been contaminated with battery fluid. Replace battery with a new one ­ Linn part no: MISS 011 Replace C12 first (easy to replace) then replace U7 & U8.

Probably constant

Power supply fault on main board. The control board power comes from the emitter (square pad) of Q77 (attached to one of the heatsinks) on the main board. It should measure +8V

One or more display LEDs dim or dead Page8 Contents

LK1 works okay otherwise.

Faulty display LED

Firstly check which board is causing the fault ­ it could be the main board failing to supply the correct voltage or it could be the control board pulling the voltage down. If you have another LK1 try replacing the control board. See Introduction to Fault Finding section (accessible via Linfo Website - Product Information) for tips on how to trace fault. See also circuit diagrams. If the fault is located on the main board, try replacing Q77 ­ Linn part no: TRAN 006. Replace LED ­ Linn part nos: MISS 004 (green LED) MISS 005 (red LED)

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

LK1 loses all settings (volume setting, input selected, memory settings etc) when unit is switched off and back on. LK1 takes actions by itself ­ i.e. volume changes, selects inputs, unmutes etc.

Probably constant

Intermittent and random.

Battery ­ BATT1 on control board faulty. To check, measure across the battery from one side to the other ­ it should measure about 3.5V dc. If it measures lower than about 2V, the battery is faulty. U7, U8 or C20 on control board faulty.

Replace battery ­ Linn part no: MISS 011.

Replace C20 first (easy to replace) and if that does not fix it, try U7 & U8 Linn part numbers: U7 & U8 - IC 015 C20 - CAP 003

Remote Control Problems
Symptom LK1 cannot be controlled via remote handset. Works okay via front panel controls LK1 cannot be controlled via remote handset. Works okay via front panel controls Circumstances Probably constant Possible Cause(s) Remote handset faulty or remote handset batteries require replacement. Cure Try fitting new batteries Try another working handset.

Probably constant

LK1 cannot be controlled via remote handset. Works okay via front panel controls Poor control or no control via remote handset. Works okay via front panel controls

Probably constant

Remote control is not enabled on LK1 control board. On the LK1 remote handset, there is a button marked `Pre' and several other buttons beside it in the same group. If one of these other buttons is pressed, this disables the remote control of the LK1 ­ to enable the remote again ­ press `Pre'. Remote receiver diode (D15 on Control board) is faulty.

Press `pre' on remote handset.

Replace D15 ­ Linn part no: MISS 007

All the above Remote faults have been ruled out May be intermittent

U2 (remote receiver IC) or U6 (main processor IC) on Control board faulty.

Replace U2 (Linn part no: IC 010) or U6 (Linn part no: IC 017)

Page9 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Control via Front Panel
Symptom One or more buttons either do not work at all or do not work well Circumstances May be intermittent Possible Cause(s) Membrane & switch contact require cleaning Cure Remove control board from Facia. With a dry, clean tissue or cloth, vigorously wipe the switch contacts on the control board. Clean membrane contacts (the black circular pads) in a similar way as switch contacts but with more care as it can be torn by rough handling. Replace U1 ­ Linn part no: IC 009.

No control via front panel ­ one of the display LEDs may be permanently lit. Some buttons work and some buttons do not

Probably constant

U1 on control board (encoder IC) faulty.

May be intermittent

Control board requires upgrade

See Control Board Upgrade procedure (accessible via Linfo Website - Product Information)

Page10 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Amplifier problems
It is assumed at this point that the LK1 is definitely the cause of the fault ­ that you have traced the fault to the LK1 and ruled out all other aspects of the system (e.g. interconnect leads, power amp, speakers, sources etc.). If you have not, please do so before proceeding to ensure that you are not fault-finding on a product that is not faulty while the fault remains in the system.

Audio (Listen) output
Symptom No output from both channels One channel is louder than the other on all inputs Cross-talk from one (or more) input to other inputs. May also have a loud crackling noise intermittently Loud crackling, buzzing or electronic noise through speakers intermittently. May also have cross-talk between inputs. Cross-talk from one (or more) input to other inputs. May also have a loud crackling noise intermittently Circumstances May be intermittent Display & control may be affected Probably constant Possible Cause(s) Power up, display, or control fault ­ see these faults as listed above. Balance is set off centre. Cure See Power up and Display & Control faults listed above. Centre the balance setting

May be intermittent

One of the display LEDs on control board is leaking current.

See LK1 Cross-talk Repair Procedure (accessible via Linfo Website - Product Information)

Intermittent Symptoms may vary.

One of the display LEDs on control board is leaking current.

See LK1 Cross-talk Repair Procedure (accessible via Linfo Website - Product Information)

Probably constant If the switches within the IC go faulty, they usually get jammed in the `Closed' position. This means that the affected input will be permanently switched on and this causes crosstalk. E.g. if AUX switching IC is faulty and you are trying to listen to TUN while a source is playing on AUX, one channel of the AUX source may be heard on the TUN input.

Switching IC(s) faulty. Each input has its own switching IC, which switches Listen & Record for that input. If one input's IC fails it can affect the other inputs. The IC's in question are U1 ­ U6 and they are configured as follows: U1 ­ Phono U2 ­ Phono U3 ­ TP2 U4 ­ TP1 U5 ­ AUX U6 ­ TUN

Either replace all the switching IC's listed ­ Linn part no: IC 001 for all IC's; or by carrying out some checks, you may be able to narrow the fault down to the faulty IC(s) and replaced it/them only. If the symptom is cross-talk, then usually the faulty input will crosstalk to other inputs, but these inputs do not cross-talk back to the faulty one. If the symptom is loud thump, then usually the faulty input will be least affected by the fault.

Page11 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

Crackling and/or rustling noise at the output of one channel

Firstly rule out the LED fault above. Probably intermittent. Noise varies in volume and intensity. Happens after unit has been switched off and then on again.

Transistor breaking down. You may be able to narrow down the fault by checking exactly what inputs/outputs are affected, whether the fault increases/decreases with volume etc. Backup battery (BATT1 on control board) faulty ­ causes sound to mute completely (volume is at absolute zero) on all inputs Volume control DAC faulty

See Introduction to Fault Finding (accessible via Linfo Website - Product Information) for tips on how to trace.

No output from all inputs.

Output of one or both channels dead on all inputs When volume is set to minimum, the music is still heard.

Probably constant

To temporarily fix, simply turn up the volume when unit is first powered up. To fix permanently, replace the back-up battery ­ Linn part no: MISS 011 Replace DAC ­ Linn part no: IC 003 See LK1 Gain Modification sheet (accessible via Linfo Website - Product Information).

Constant

Slight hum on both channels of MM or MC input

May be intermittent and/or vary in volume & intensity.

This is normal. The lowest volume setting of the LK1 is NOT absolute zero. If absolute zero is required, press Mute. If the lowest volume is too loud, a mod can be done to reduce the gain of the LK1 by 8dB. A certain amount of noise is to be expected on the phono inputs due to the massive gain level required there. Earthing lead between arm & LK1 casing is broken or not properly connected Ground (black) wire between phono socket and main board inside the LK1 is broken or not making good contact.

Hum on both channels of MM or MC input Loud hum on one channel of MM or MC input

May be intermittent

Compare noise levels to another LK1 or another pre-amp phono stage ­ some low level hum is normal and unavoidable and cannot be eliminated. Ensure continuity of Ground connection. Repair the connection ­ re-solder or replace wire as necessary.

One channel of MM or MC input dead or distorted. Some crackling may occur

Probably intermittent. Ensure firstly that the fault is not caused by turntable or interconnect leads etc. Rule out Phono hum faults above. May be intermittent Symptoms may vary

Signal (red) wire between phono socket and main board inside the LK1 is broken or not making good contact

Repair the connection ­ re-solder or replace wire as necessary.

Page12 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.

20th August 1999

LK1 Service Manual

No output from one or both channels

All inputs May be intermittent

Faulty:Power amp Speakers Interconnect leads Speaker cables

No output from one or both channels

May be all inputs or possibly limited to one or two inputs. May be intermittent

Check that all input & output leads are inserted in the correct places Check that all input & output leads are pushed fully home. Check that the source selected on display corresponds with the source connected to the input. Check that the source is powered up, is playing and is working okay.

Find & repair or replace faulty part. Do not assume LK1 or any other part of system is faulty ­ check & fault find system. See Introduction to Fault Finding section (accessible via Linfo Website - Product Information) and also Service Procedures section (also accessible via Linfo Website Product Information) for tips on how to fault find in a system. Find and fix the problem. See Introduction to Fault Finding section (accessible via Linfo Website - Product Information) and also Service Procedures section (also accessible via Linfo Website Product Information) for tips on how to fault find in a system.

Tape (record) Output
Symptom Tape (record) output dead or ­ no recordings Tape (record) output dead Circumstances Constant Possible Cause(s) Tape deck faulty Cure Repair/replace Tape deck.

Constant

Tape (record) output faulty. Possible Crosstalk from one record output to others. Possible loud thump when certain record outputs are switched.

Probably constant If the switches within the IC go faulty, they usually get jammed in the `Closed' position. This means that the affected input will be permanently switched on and this causes crosstalk. E.g. if AUX switching IC is faulty and you are trying to record from TUN while a source is playing on AUX, one channel of the CD may be heard on the tape.

Interconnect lead from LK1 to tape deck is wrongly connected Interconnect lead from LK1 to tape deck is faulty Switching IC(s) faulty. Each input has its own switching IC, which switches Listen & Record for that input. If one input's IC fails it can affect the other inputs. The IC's in question are U1 ­ U6 and they are configured as follows: U1 ­ Phono U2 ­ Phono U3 ­ TP2 U4 ­ TP1 U5 ­ AUX U6 ­ TUN

Check, repair connections

Either replace all the switching IC's listed ­ Linn part no: IC 001 for all IC's; or by carrying out some checks, you may be able to narrow the fault down to the faulty IC(s) and replaced it/them only. If the symptom is cross-talk, then usually the faulty input will crosstalk to other inputs, but these inputs do not cross-talk back to the faulty one. If the symptom is loud thump, then usually the faulty input will be least affected by the fault.

Page13 Contents

Copyright © 1999 Linn Products Limited. All rights reserved.