Text preview for : MX M260344.pdf part of Sharp Andromeda II refresh Polish and English language



Back to : Andromeda ll refresh.part | Home

Date: Model: Ref.: Colour: Page:

19th March 2010 See Below DCE788 White 1 of 2

TECHNICAL BULLETIN
ROM version upgrade ... (1)

1. Model Name 2. Description

MX-M260/M310, MX-PB12, AR-FX7 MCU, PCL and FAX-ROM version upgrade
Executed from the production in December 2009 Target model MX-M260 Series MX-M310 Series Packing control No. A01 A01 MCU V02.00 V02.00 IMC V05.00 V01.00 OPE V01.00 V01.00 PCL V01.06 V01.06 FAX V04.01 V04.01

Note: Version upgrade of FAX (AR-FX7) has been executed from January 2010 for Europe and from December 2009 for other regions. Changes: Refer to the attached sheet.

1/2

Sharp Electronics (UK) Ltd., Document Systems Support

3. Changes
No. 1 UI relation Item Description If the screen is switched when the delivery tray is full, the delivery tray full indicator flashes. This problem is fixed. If toner end occurs when performing staple sort copying, a message prompting removal of the paper in the staple compiler appears after replacing toner, and staple job is not resumed. This problem is fixed. If paper runs out during printing with sheets stapled and it is left in that state for a long time, printing is not resumed even if paper is loaded. This problem is fixed. If the FAX setting list is printed when the delivery tray is full, a message prompting removal of the delivered paper appears, and hang-up occurs. This problem is fixed. If "F1-15" trouble occurs when setting the E-mail alert, the E-mail alert is sent; however the trouble code is not listed in the text. This problem is fixed. A check item for the sensor (FPLS) of the inner finisher added as a countermeasure against jam during stapling has been added to SIM3-21. A change has been made so that the display timing of the message appearing when the drum and developer reach the life cycle can be selected by the soft SW. Sim55-1 Soft SW 4-6 0: The life is determined by the counter or running distance. (Conventional display: Default) 1: The life is determined by the counter only. 8 Others Flash ROM made by MACRONIX can be used.

2

Copy relation

3

Printer relation

4

List print relation

5

E-mail alert relation

6

Simulation relation

7

Soft SW relation

2/2

Sharp Electronics (UK) Ltd., Document Systems Support