Text preview for : ARFX10SM.pdf part of Sharp AR-C172M AR-C172M SERVICE MANUAL



Back to : SERVICE MANUAL.part1.rar | Home

SERVICE MANUAL
CODE : 00ZARFX10/A1E

DIGITAL FULL COLOR MULTIFUNCTIONAL SYSTEM OPTION FAX EXPANSION KIT (For U.K., France, Germany, Sweden, Australia, New Zealand)

MODEL
CONTENTS

AR-FX10

OPTION AR-MM9

[1] PRODUCT OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 [2] CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 [3] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 1 [4] EXTERNAL VIEWS AND INTERNAL STRUCTURES . . . . . . . . . 4 - 1 [5] UNPACKING AND INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . 5 - 1 [6] SIMULATIONS, FAX SOFTWARE SWITCH . . . . . . . . . . . . . . . . 6 - 1 [7] MACHINE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 1 [8] ELECTRICAL SECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 - 1

Parts marked with " " are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.

SHARP CORPORATION

This document has been published to be used for after sales service only. The contents are subject to change without notice.

CONTENTS

[1] PRODUCT OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

[6] SIMULATIONS, FAX SOFTWARE SWITCH 1. Entering the simulation mode . . . . . . . . . . . . . . . . . . . . 6-1

[2] CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

2. Switching the simulation mode . . . . . . . . . . . . . . . . . . . 6-1 3. Canceling the simulation mode . . . . . . . . . . . . . . . . . . . 6-1 4. Simulation list. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1

[3] SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

5. Detail of simulations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 6. FAX software switch . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13

[4] EXTERNAL VIEWS AND INTERNAL STRUCTURES 1. Operation panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 2. FAX mode (Condition settings screen) . . . . . . . . . . . . . . 4-2 [7] MACHINE OPERATION 1. Key operator programs . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 2. Originals that can be faxed . . . . . . . . . . . . . . . . . . . . . . 7-2 [5] UNPACKING AND INSTALLATION. . . . . . . . . . . . . . . . . . 5-1 3. Own number sending. . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 4. Quick On-line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 5. Trouble codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4

[8] ELECTRICAL SECTION 1. Actual wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 2. MDMC PWB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 3. TEL/LIU PWB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-25 4. FAX power unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-33

[1] PRODUCT OUTLINE
This unit provides the FAX function to the following machines: Machines to install this unit: · AR-C170M

[2] CONFIGURATION
Extended memory
* Installed to ICU PWB.

FAX-BOX unit

AR-FX10 PRODUCT OUTLINE / CONFIGURATION 1 - 1

[3] SPECIFICATIONS
(1) Transmission method
Transmission time 2 second level (Super G3/JBIG) 6 second level (G3 ECM) (A4/Standard mode, Sharp Standard original) 33.6kbps 2.4kbps automatic fallback Super G3: 33.6kbps / G3: 14.4kbps General telephone line (PSTN), F network

(8) F code transmission
Sub address Password Memory Box 50 destinations

Compression method MH, MR, MMR, JBIG Modem speed Communication speed/mode Communication line ECM

(9) Memory for Transmit/Receive
Standard Memory extended Data back-up with 2MB flash Memory Expandable (8MB)

(10) Function
Transmit Memory transmit function (Definable destinations: 50 destinations) On-hook Quick online transmit Direct transmit At on-hook only Auto reduction transmit A3 B4, A3 A4, B4 A4 Rotation transmit Re-call mode (Re-call times/interval of time to be set by key operator program (User can set the conditions for line busy and error occasion respectively.)) Book original transmit Long length original transmit (Max. 800mm for the direction that original is transported) Verification stamp function ACR function Receive Auto receive function Manual receive Memory receive Reduced receive for standard size Scaling receive for specified size Rotation receive Divided receive (To be defined by key operator program) Duplex receive (To be defined by key operator program) 2 in 1 receive Authorized receive only for specified number Prohibited receive only for specified number Auto switching between TEL/ FAX External phone connection, remote Remote switch number (1 digit: 0 ­ 9 / setup Default: 5) Ringing sound pattern ON/OFF selection (Australia, New Zealand) Answering phone connection (To avoid patent infringement) Transfer function at output trouble Auto wake up mode Call hold Anti junk fax settings (Max. 50)

(2) Number of Support Line
Standard Expansion 1 line Not provided

(3) Transmission Mode
RSPF/OC transmission switching (Switching during the reading is not feasible)

(4) Fax Image Quality/Image Process
Half tone reproduction Quality selection Resolution Equivalent to 256 levels

Exposure adjustment Auto / Manual (5 steps) Half-tone ON/OFF Standard (8x3.85 lines/mm, 203.2x97.8dpi) Fine (8x7.7 lines/mm, 203.2x195.6dpi) Super Fine (8x15.4 lines/mm, 203.2x391dpi) Ultra Fine (16x15.4 lines/mm, 406.4x391dpi)

(5) Record Size (Fax reception)
Max. record width Record size 293mm A3 ­ A5, 8.5" x 11"

(6) Dial
Manual dialing Chain dialig Re-dialing One-touch dial Speed dialing Group dialing Dial search Program Handset To be entered by 10-key, # key, key To be used in conjunction with Pause, up to 64 digits To recall the latest number dialed with 10key 500 destinations (not including the number of scanner address) To be registered in the one-touch dialing Alphabet order search, User index groups 8 destinations Not provided

(7) Definition of Multiple Destinations
Usable dials Manual dial, One-touch dial and Group dial (Because scanner and fax is separated, fax and e-mail mixed broadcasting cannot be made.)

Definable destination Max. 100 destinations Sequential broadcasting Simultaneous Scan to E-mail

Sequential transmission request

AR-FX10 SPECIFICATIONS 3 - 1

Special Time setting function Polling receive Memory polled Cover function Print at sender Page division Page combination Confidential Transmit broadcast direction Transmit message Scaling transmit Report/ Transmit/receive record List Transmit/receive result function Programmed one-touch key list Group list Sender list Confidential box check list Transmit group list Program list Reserved transmit list Memory box list Memory clear notice list PBX setting R key display

(F code method) (F code method) (Integrated to the memory box list) (Default: OFF (Germany, France)) (Default not displayed: OFF (Germany, France)) (1 ­ 9 times / Default: 9 times (France))

Other

Manual/Auto receive auto select call number setting Date format select setting

AR-FX10 SPECIFICATIONS 3 - 2

[4] EXTERNAL VIEWS AND INTERNAL STRUCTURES
1. Operation panel
1 2 3 4 5 6 9

7
1 Touch panel

8

2 3

Mode select keys [IMAGE SEND] key

4 5

Numeric keys [C] key (clear key)

6

[CA] key (clear all key)

7 8 9

[] key [BLACK COPY START] key [COLOR COPY START] key

· Messages and keys appear on the touch panel. Key input is accomplished by touching the keys. · When a key in the touch panel is touched, a beep sounds and the key is highlighted. · Keys that cannot be selected in a screen are greyed out. If touched, a double-beep will sound to alert you that the key cannot be selected. Use these keys to change modes. Press to switch to fax mode. The initial screen of fax mode will appear. When the network scanner option is installed, touch this key to return to the initial screen of fax mode or scanner mode, whichever mode was selected last. (Pressing the [IMAGE SEND] key in a copy screen or printer screen returns you to the initial screen of fax mode.) To switch to the initial screen of fax mode from the initial screen of scanner mode, touch the [SCANNER/FAX] key. Use to enter fax numbers, sub-addresses, passcodes, and numerical settings. Use to clear a mistake when entering fax numbers, sub-addresses, passcodes, and numerical settings. One digit is cleared each time you press the key. When an original is being scanned, this key can also be used to cancel scanning. Use to cancel a transmission or programming operation. When this key is pressed, the operation is cancelled and you return to the initial screen described on the following page. This key is also used to cancel a resolution, paper size, or special function setting that was selected when sending a fax. This is used to produce tone signals when you are on a pulse dial line. Press to begin scanning an original for fax transmission. Not used when using the machine as a fax machine. (For information on this key.)

AR-FX10 EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 1

2. FAX mode (Condition settings screen)
The condition settings screen of fax mode is displayed by pressing the [IMAGE SEND] key while the print mode, copy mode, or job status screen appears in the touch panel. In the explanations that follow, it is assumed that the initial screen that appears after pressing the [IMAGE SEND] key is the condition settings screen (shown below). If you have set the display to show the address directory screen (next page) when the [IMAGE SEND] key is pressed, touch the [CONDITION SETTINGS] key in the address directory screen to display the condition settings screen. "Default display settings" in the key operator programs can be used to select whether the condition settings screen (below) appears or the address directory screen (next page) appears as the initial screen when the [IMAGE SEND] key is pressed. When the network scanner option is installed, you will return to the initial screen of fax mode or scanner mode, whichever mode was selected last. (Pressing the [IMAGE SEND] key in a copy screen or printer screen returns you to the initial screen of fax mode.)

A. Condition settings screen
The display is initially set (factory setting) to show the following condition settings screen as the initial screen.

1
READY TO SEND.

2

3
SPEAKER FAX MEMORY:100% AUTO RECEPTION

4
REDIAL ADDRESS DIRECTORY SUB ADDRESS

14 13 12 11
AUTO EXPOSURE STANDARD RESOLUTION

5 6 7 8

SPECIAL MODES AUTO ORIGINAL SCANNER

ADDRESS REVIEW FAX

10
1 2 3 Message display Memory and reception mode display [SPEAKER] key

9

Messages appear here to indicate the current status of the machine. The icon at left ( ) indicates fax mode. This shows the amount of fax memory that is free and the currently selected reception mode. Touch the [SPEAKER] key to dial and transmit a fax manually. During dialing it changes into the [PAUSE] key, and after touching the [SUB ADDRESS] key it changes into the [SPACE] key. Touch this key to redial the number most recently dialed with the numeric keys or a one-touch key. After dialing, this key changes into the [NEXT ADDRESS] key. Touch this key to display the address directory screen (next page). Touch this key when you want to use an auto-dial number (one-touch dialing or group dialing). Touch this key to enter a sub-address and passcode when using F-code transmission. When performing a broadcast transmission, touch this key to check your selected destinations. The selected destinations will appear and any unneeded destinations can be deleted. This key appears when the network scanner option is installed. Touch the key to switch between the scanner screen and the fax screen. When the fax screen appears, "FAX" is highlighted. When the scanner screen appears, "SCANNER" is highlighted. Touch this key to set one of the following special functions: · Timer transmission · Polling · Dual page scan · Program · Memory box Icons appear here when you touch the [ORIGINAL] key and select two-sided scanning. The icons can be touched to open function selection screens. Touch this key when you wish to manually set the size of the original to be scanned or scan both sides of the original. Touch this key to change the resolution setting for the original to be scanned. The selected resolution setting will be highlighted above the key. The initial factory setting is [STANDARD]. Touch this key to change the exposure setting for the original to be scanned. The selected exposure setting will be highlighted above the key. The initial factory setting is [AUTO]. When a special function such as polling or dual page scan is selected, a special function icon appears here.

4 5 6 7 8

[REDIAL] key [ADDRESS DIRECTORY] key [SUB ADDRESS] key [ADDRESS REVIEW] key [SCANNER/FAX] key

9

[SPECIAL MODES] key

10 11 12 13 14

Two-sided original icon display [ORIGINAL] key [RESOLUTION] key [EXPOSURE] key Special function icon display

AR-FX10 EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 2

B. Address directory screen (alphabetically ordered)
The screen below appears initially when the address directory is set as the initial screen using "Default display settings" in the key operator programs.

2
READY TO SEND.

SPEAKER B D

REDIAL CONDITION SETTINGS SUB ADDRESS

A C

3

1
E G FREQUENT USE ABCD F H EFGHI JKLMN OPQRST UVWXYZ

ADDRESS REVIEW

ABC

GROUP

5
1 One-touch key display

4

2 3 4 5

Display switching keys [CONDITION SETTINGS] key [ABC GROUP] key Index keys

This shows the one-touch keys that have been stored on the selected "index card". The key type is indicated by the icon at the right. One-touch keys in which a fax number is stored are indicated by a " " icon. The display is initially set to show 8 keys. This can be changed to 6 or 12 using the key operator program. In cases where the one-touch keys cannot all be displayed on one screen, this shows how many screens are left. Touch the keys to move through the screens. This displays the condition settings screen (previous page), which is used to set various conditions. Touch this key to switch between the alphabetical index and the group index. One-touch key destinations are stored on each of these index cards (alphabetical index or group index). Touch this key to switch between the indexes. Group indexes make it possible to store one-touch keys by group with an assigned name for easy reference. This is done with the custom settings. Frequently used one-touch key destinations can be stored on the [FREQUENT USE] card for convenient access.

NOTE The screen showed above is the alphabetical address directory. If desired, the initial screen can be set to the group address directory.

AR-FX10 EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 3

[5] UNPACKING AND INSTALLATION

· Start installation after checking that the COMMUNICATION indicator on the operation panel is neither lit nor blinking.

(3)

Secure the fax interface cable.

Attach the supplied snap band to the fax interface cable as shown in the illustration and fit the snap band into the hole of the OP connector mounting plate. Pull the interface cable gently to your side to check that the snap band is secured to the OP connector mounting plate and that the snap band on the cable is not loosened. Then, cut off unnecessary portions with nippers.
Line cable: 1 pc. U.K Australia

Parts included

Snap band

Screw B: 1 pc. Snap band: 1 pc.

France Germany For other destinations

Fax box mounting plate (for main unit): 1 pc.

Operation manual: 1 volume

(1)

Turn off the power switch of the printer.

Turn the power switch located on the left side of the printer to the "OFF" position. Then remove the power plug of the main unit from the outlet.

(4)

Attach the rear connecting cabinet.

1) Cut out the cut-out portion. 2) Pass the fax interface cable through the cut-out portion and attach it to the rear connecting cabinet taking care about the engagement with the rear cabinet.
OFF

3) Secure the cabinet with two screws at the two positions shown in the illustration. 4) Tighten the rear cabinet securing screw that has been loosened at 1) in step (2).

(2)

Remove the rear connecting cabinet.

1) Loosen the rear cabinet securing screw. 2) Remove the three rear connecting cabinet securing screws and lift the rear connecting cabinet to remove it taking care about the engagement with the rear cabinet.

(5)
3) Peel the securing tape of the FAX interface cable stored in the printer and pull out the cable from the wire saddle.

Attach the fax box mounting plate (for main unit).

1) Remove the two rear cabinet securing screws. 2) Use the two screws that have been removed to secure the fax box mounting plate (for main unit) with the rear cabinet.

Wire saddle

AR-FX10 UNPACKING AND INSTALLATION 5 - 1

(6)

Attach the fax box unit.

(8)

Connect the fax interface cable.

1) Remove the rear cabinet securing screw. 2) Insert the shaft of the fax box mounting plate into the mounting section of the fax box.

Connect the connector of the fax interface cable to the connector of the fax box unit.

· If mounting of additional fax memory is not needed, proceed to step (10).

Operation for mounting additional fax memory (AR-MM9)

3) Secure the fax box unit with screw B and the rear cabinet securing screw that has been removed at 1).

Additional fax memory

(9)

Mount the additional fax memory to the ICU PWB.

1) Remove the two screws from the upper output tray and slide the tray in the direction of the arrow to remove it.
Screw B
Screws

Upper output tray

2) Remove the two screws from the ICU cover and slide the cover in the direction of the arrow to remove it.

Screws

(7)

Connect the fax power supply connector.

1) Remove the connector cover securing screw from the back of the printer and remove the connector cover.
ICU cover

3) Mount the additional fax memory to the socket of the ICU PWB.

2) Ensure that the fax power switch is set to "OFF." 3) Connect the fax power supply connector to the connector of the printer and secure it by tightening the three screws.
IC U

Screws OFF

4) Reattach the ICU cover to its original position and secure it with the two screws.
Screws

5) Reattach the upper output tray to its original position and secure it with the two screws.

AR-FX10 UNPACKING AND INSTALLATION 5 - 2

(10) Turn on the main switch of the printer and the fax power switch.
Insert the power plug of the printer to the outlet and turn on the main power switch and the fax power switch.
ON ON

(12) Set the destination for the fax.
1) Switch the operation panel to the copy mode and use the key operation [P] [] [C] and [] to enter the simulation mode. 2) Use the 10-key pad to enter [66] in the main code entry screen and press the [START] key.

0
TEST SIMULATION

CLOSE

INPUT A MAIN PROGRAM NUMBER BY 10-KEY PAD, AND PRESS START.

66

(11) Set the destination for the main unit.
· Be sure to set the destination for the main unit before setting the destination for the fax. 1) Switch the operation panel to the copy mode and use the key operation [P] [] [C] and [] to enter the simulation mode. 2) Use the 10-key pad to enter [26] in the main code entry screen and press the [START] key. 3) Use the 10-key pad to enter [2] in the sub-code entry screen and press the [START] key.

0
TEST SIMULATION NO. 66

CLOSE

0
TEST SIMULATION

CLOSE

INPUT A MAIN PROGRAM NUMBER BY 10-KEY PAD, AND PRESS START.

26

INPUT A SUB PROGRAM NUMBER BY 10-KEY PAD, AND PRESS START. 1:FAX SOFT SW. SETTING 7:IMAGE MEMORY PRINT OUT 2:FAX SOFT SW. CLEAR 8:MESSAGE OUTPUT CHECK (WITHOUT ADJUSTMENT VALUE) (LEVEL MAX) 9:MESSAGE OUTPUT CHECK(SOFT SW) 3:FAX PWB MEMORY CHECK 4:SIGNAL OUTPUT CHECK(LEVEL MAX) 10:IMAGE MEMORY CLEAR 11:300bps SIGNAL OUTPUT 5:SIGNAL OUTPUT CHECK(SOFT SW.) (LEVEL MAX) 6:PASS CODE PRINT OUT

2

1/3

4) To set the U.K. as the destination, enter [10110100] using the 10-key pad and select [SET] [EXECUTE], and [YES] in this order to register it. 3) The sub-code list is displayed. Use the 10-key pad to enter [6] and press the [START] key. When you press the [CA] key, this machine will be rebooted and will start with the setting of the selected destination.

0 0
TEST SIMULATION NO. 26 TEST SIMULATION NO. 66-02

CLOSE

CLOSE

INPUT A SUB PROGRAM NUMBER BY 10-KEY PAD, AND PRESS START. 26 2:SIZE SETUP 38:ENGINE LIFE OVER SETTING 3:AUDITOR SETUP 41:PAMPHLET MODE AMS SETTING 5:A3(11 X 17)COUNTUP 49:COPY SPEED MODE SETUP 6:DESTINATION SETUP 50:FUNCTION SETTING 10:NETWORK SCANNER 52:A BLANK PAPER COUNT MODE SETUP TRIAL MODE SETUP 53:DISABLING OF AUTOMATIC 1/2 35:TROUBLE MEMORY MODE SETUP COLOR CALIBRATION.

FAX SOFT SW. CLEAR(WITHOUT ADJUSTMENT VALUE) PRESENT: -------NEW: DEST CODE ARE YOU SURE? YES NO

SET

EXECUTE

1/1

4) Select the desired destination from the destination list and press the [START] key. When you press the [CA] key, this machine will be rebooted and will start with the setting of the selected destination for the main unit. (For example, to set the U.K. as the destination, select [U.K.] from the destination list.)
TEST SIMULATION NO. 66-02

0
CLOSE

FAX SOFT SW. CLEAR(WITHOUT ADJUSTMENT VALUE) PRESENT: -------NEW: 10110100 DEST CODE ARE YOU SURE? YES NO

SET

EXECUTE

0
TEST SIMULATION NO. 26-06

1/1

CLOSE Inch U. K. Japan Aus.

DESTINATION SETUP U. S. A. AB _ B AB _ A

Canada Europe China

NOTE: To display the list of country codes, press the [DEST CODE] key. Separate table 1: Setting value of destination for fax Destination JAPAN U.S.A. AUSTRALIA NEWZEALAND U.K. FRANCE GERMANY SWEDEN 0 1 0 0 1 0 0 1 FAX Software SW No 1 ­ 8 0 0 0 0 0 0 0 1 1 0 1 0 0 0 0 1 0 0 1 1 1 1 1 1 0 1 1 0 1 0 0 1 1 1 1 0 0 0 0 0 1 0 0 1 0 0 1 0 0 1 1 0 0 1 0 1

AR-FX10 UNPACKING AND INSTALLATION 5 - 3

(13) Clear the image memory.
· If an additional memory (AR-MM9) has been mounted, be sure to carry out this step. If no additional memory has been mounted, this step is not necessary. 1) Switch the operation panel to the copy mode and use the key operation [P] [] [C] and [] to enter the simulation mode. 2) Use the 10-key pad to enter [66] in the main code entry screen and press the [START] key.

(14) Connect the line cable to the fax box unit.
Connect the line cable to the fax box unit.

TEL
LINE

0
TEST SIMULATION

CLOSE

INPUT A MAIN PROGRAM NUMBER BY 10-KEY PAD, AND PRESS START.

66

3) Use the 10-key pad to enter [10] in the sub-code entry screen and press the [START] key.

0
TEST SIMULATION NO. 66

CLOSE

INPUT A SUB PROGRAM NUMBER BY 10-KEY PAD, AND PRESS START. 10 1:FAX SOFT SW. SETTING 7:IMAGE MEMORY PRINT OUT 2:FAX SOFT SW. CLEAR 8:MESSAGE OUTPUT CHECK (WITHOUT ADJUSTMENT VALUE) (LEVEL MAX) 3:FAX PWB MEMORY CHECK 9:MESSAGE OUTPUT CHECK(SOFT SW) 4:SIGNAL OUTPUT CHECK(LEVEL MAX) 10:IMAGE MEMORY CLEAR 5:SIGNAL OUTPUT CHECK(SOFT SW.) 11:300bps SIGNAL OUTPUT (LEVEL MAX) 1 / 3 6:PASS CODE PRINT OUT

4) In the submenu screen, press [EXECUT] and [YES].

0
TEST SIMULATION NO. 66-10

CLOSE

IMAGE MEMORY CLEAR

ARE YOU SURE?

YES

NO

EXECUTE

5) The screen shown on the right is displayed and memory clear operation is executed.

0
TEST SIMULATION NO. 66-10

CLOSE

IMAGE MEMORY CLEAR

ARE YOU SURE?

YES

NO

EXECUTE

6) After several minutes, memory clear operation is completed. (When highlighting of the [YES] key disappears, the clear operation is complete.) If you press the [CA] key, the screen shown on the right is displayed. Turn off both power switches and then on again.

0
TEST SIMULATION NO. 66-10

CLOSE

IMAGE MEMORY CLEAR

TO TURN THE COPIER ON, TURN THE POWER SWITCH TO OFF THEN ON AGAIN.

ARE YOU SURE?

YES

NO

EXECUTE

AR-FX10 UNPACKING AND INSTALLATION 5 - 4

[6] SIMULATIONS, FAX SOFTWARE SWITCH
1. Entering the simulation mode
a. Nomal mode Enter the copy mode and perform the following procedures. [P] [*] [C] [*] [Main code] [START] [Sub code] [START] b. FAX mode Enter the copy mode and perform the following procedures. [9] [*] [8] [#] [7]

2. Switching the simulation mode
Press [CUSTOM SETTINGS] to return to the code entry screen.

3. Canceling the simulation mode
Press [CA] key to cancel the simulation mode.

4. Simulation list
Code Main Sub 22 5 6 Function (Purpose) Used to check the ROM version of each unit (section). Used to print the setting and adjustment data list. Used to check the number of use of FAX. (When the FAX is installed) Used to clear the FAX counter. (When the FAX is installed) Collective adjustment of FAX mode (all modes) document scan density (When the FAX is installed) Used to adjust the FAX mode (normal mode) document scan density (when the FAX is installed). Used to adjust the FAX mode (fine text mode) document scan density (when the FAX is installed). Used to adjust the FAX mode (super fine mode) document scan density (when the FAX is installed). Used to adjust the FAX mode (ultrafine mode) document scan density (when the FAX is installed). Used for firmware version up (Machine/FAX). Used to adjust image loss in the FAX/scanner mode. Used to change/set the soft SW setting (FAX-related items). (When the FAX is installed.) Used to initialize the soft SW setting (FAX-related items) according to the destination. (When the FAX is installed.) Used to check the memory on the Modem controller. (When the FAX is installed.) Used to select a signal and send it to the line and speaker (at the max. level). (When the FAX is installed.) Used to select a signal and send it to the line and the speaker. (Level: Soft SW setting) (When the FAX is installed.) Used to print the check list of the contents when confidential registration is made. (When the FAX is installed.) Used to print all the images in the memory. (When the FAX is installed.) Others Adjustment/Setting/ Operation data output, check (display, print) FAX Adjustment/Setting/ Operation data output, check (display, print) Data clear FAX Adjustment ICU PWB / FAX Purpose Section Software Data Setting/ Adjustment data Item

11

Counter

24 46

10 40

Counter Picture quality

41

Adjustment

ICU PWB / FAX

Picture quality

42

Adjustment

ICU PWB / FAX

Picture quality

43

Adjustment

ICU PWB / FAX

Picture quality

44

Adjustment

ICU PWB / FAX

Picture quality

49 50 66

1 27 01

Version up Adjustment Setting

Firmware (Machine/FAX) FAX/Scanner FAX

Operation Picture quality

02

Setting

FAX

Data

Initializing

03

Operation test/check

FAX

Operation

04

Operation test/check

FAX

Operation

05

Operation test/check

FAX

Operation

06

Data output/check

FAX

Data

Confidential pass code

07

Data output/check

FAX

Data

Image data

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 1

Code Main Sub 66 08

Function (Purpose) Used to select a voice message and send it to the line and the speaker (at the max. level). (When the FAX is installed.) Used to select a signal and send it to the line and the speaker. (Level: soft SW setting). (When the FAX is installed.) All the images in the memory can be deleted. (When the FAX is installed.) Used to select a pattern and send it to the line and the speaker at 300bps (at the max. level). (When the FAX is installed.) Used to select a pattern and send it to the line and the speaker at 300bps. (Level: soft SW setting) (When the FAX is installed.) Used to register a dial number for test used in SIM 66-14/15/16. (When the FAX is installed.) Used to adjust and check the make time of dial pulse (10pps). (When the FAX is installed.) Used to adjust and check the make time of the dial pulse (20pps). (When the FAX is installed.) Used to adjust and check the send level of DTFM signal. (When the FAX is installed.) Used to select the DTFM signal (1 ­ 9, 0, *, #) to send it to the line and the speaker (at the max. level). (When the FAX is installed.) Used to select the DTFM signal (1 ­ 9, 0, *, #) to send it to the line and the speaker (Level: soft SW setting). (When the FAX is installed.) Used to write the ICU PWB SRAM contents (various set values and user data) into the Flash ROM (ARMM9). (When the FAX is installed.) Used to write the Flash ROM (ARMM9) contents (SRAM contents written with SIM 66-19) into the ICU PWB SRAM. (When the FAX is installed.) Used to print various registration information, communication, file management, system error, and protocol information. (When the FAX is installed.) Used to set the sound volume of the handset. (When the FAX is installed.) Used to download the FAX program. (When the FAX is installed.) Used to clear the data in the FAST memory. (When the FAX is installed.) Used to clear the data related to the address book (one-touch registration, program registration/ expansion, interface memory box registration, each table contents). (When the FAX is installed.) Used to check the status change of the TEL/LIU sensor. (When the FAX is installed.) Used to set ON/OFF of each port for output to the TEL/LIU. (When the FAX is installed.) Used to check (compare) the received data (fixed data) from the line to make judgment of error or normal. (When the FAX is installed.)

Purpose Operation test/check FAX

Section Operation

Item

09

Operation test/check

FAX

Operation

10 11

Data clear Operation test/check

FAX FAX

Data Operation

Image data

12

Operation test/check

FAX

Operation

13

Setting

FAX

Data

Registration

14

Adjustment

FAX

Operation

15

Adjustment

FAX

Operation

16

Adjustment

FAX

Operation

17

Operation test/check

FAX

Operation

18

Operation test/check

FAX

Operation

19

Backup

FAX

Data

20

Backup

FAX

Data

21

Check

FAX

Data

22

Setting

FAX

Operation

23 24

Setting Data clear

FAX FAX

Operation Data Initializing

29

Data clear

FAX

Data

Initializing

30

Operation test/check

FAX

Operation

31

Setting

FAX

Operation

32

Operation test/check

FAX

Operation

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 2

Code Main Sub 66 33

Function (Purpose) Used to detect signals (BUSY TONE/CNG/CED/FNET) from the line. (When the FAX is installed.) Used to display the time required for sending the test image data. (When the FAX is installed.) Used to rewrite the Modem program. (When the FAX is installed.) Used to check send/receive (data/ command line) from the Modem controller to the MFP controller. (When the FAX is installed) Used to set the destination of the FAX. (When the FAX is installed.)

Purpose Operation test/check FAX

Section Operation

Item

34

Operation test/check

FAX

Operation

35 36

Setting Operation test/check

FAX FAX

Data Operation

Writing

39

Setting

FAX

Specifications

5. Detail of simulations
22 -6 Adjustment/Setting/Operation data output, check, (display, print) Used to print the setting and adjustment data list. Data Setting/Adjustment data

22
22 -5 Others Used to check the ROM version of each unit (section). Software

Purpose Function (Purpose) Item

Purpose Function (Purpose) Item

Operation/ If there is any problem in the software, check the Procedure ROM version of each section with this simulation and replace with a new version if necessary. (Sections to be displayed) ICU PCU SCANNER COL REV DATA OPE PROG PRT BOOT PRT PROG FAX FIN-SORTER PUNCH DESK LCC NIC PS ICU control Engine control section Scanner control section Color correction ROM OPE control section PRT boot PRT control section FAX control section Finisher/Sorter Punch unit Desk Large capacity cassette NIC PostScript

Operation/ When installing or servicing, execute this simulation Procedure to print and store the adjustment values and setting data for use in the next servicing. (Memory trouble, PWB replacement, etc.) In this case, the print conditions can be set optionally. 1. Select the setup item. (The selected item is highlighted.) 2. Set the item and conditions with the 10-key pad. 3. Press the [EXECUTE] key to print various data. Item Display item Low High Default Description A DATA PATTERN 1 1 1 =1 B PAPER SELECT 1 6 2 Cassette selection =1 MANUAL Manual paper feed =2 CAS1 Cassette 1 =3 CAS2 Cassette 2 =4 CAS3 Cassette 3 =5 CAS4 Cassette 4 =6 LCC LCC

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 3

22

-11 Adjustment/Setting/Operation data output, check (display, print) Used to check the number of use of FAX. (When FAX installed) FAX Counter

46
46 -40 Adjustment Collective adjustment of FAX mode (all modes) document scan density (when FAX is installed) ICU PWB/FAX Picture quality

Purpose Function (Purpose) Section Item

Purpose Function (Purpose) Section Item

Operation/ The FAX send/receive counter value is displayed. Procedure (Counter values to be displayed) Display FAX SEND FAX RECEIVED FAX OUTPUT SEND IMAGES SEND TIME RECEIVED TIME Content FAX send counter FAX receive counter FAX print number FAX send number counter FAX send time FAX receive time

Operation/ The print densities of all the modes (FAX modes) Procedure can be collectively and uniformly changed with the adjusted density level of each mode (normal, fine text, super fine, ultra fine) as the start point. 1. Select the print density adjustment mode with the scroll key. 2. Enter the adjustment value with the 10-key, and press [OK] key. The adjustment value is set. 3. Set the print condition with the scroll key and the 10-key. 4. Set a document and press [EXECUTE] key. The document is scanned at the density level set in procedure 2 and it is printed. (Item to be set) A AUTO B PAPER C EXIT TRAY Item Exposure data value (Collective) Print execution cassette selection Paper exit tray selection 3: CS2 4: CS3 Set range 1 to 99 1 to 6 *1 1 to 2 *2 6: LCC Default 50 2 2

24
24 -10 Data clear Used to clear the FAX counter. (with FAX installed) FAX Counter

*1

: 1: MFT 2: CS1 *2 : 1: R 2: S

5: CS4

Purpose Function (Purpose) Section Item

Operation/ 1. Select the counter to be cleared. Procedure 2. Press the [EXECUTE] key. The display for reconfirmation to clear is shown. 3. Select YES or NO to clear the counter. YES: Clear NO: Not clear (Counters to be cleared) Display FAX SEND FAX RECEIVED FAX OUTPUT SEND IMAGES SEND TIIME RECEIVE TIME Content FAX send counter FAX receive counter FAX print number FAX send number counter FAX send time FAX receive time

46

-41 Adjustment Used to adjust the FAX mode (normal mode) document scan density (when the FAX is installed). ICU PWB/FAX Picture quality

Purpose Function (Purpose) Section Item

Operation/ 1. Select the print density adjustment mode with the Procedure scroll key. 2. Enter the adjustment value with the 10-key, and press [OK] key. The adjustment value is set. 3. Set the print condition with the scroll key and the 10-key. 4. Set a document and press [EXECUTE] key. The document is scanned at the density level set in procedure 2 and it is printed. (Item to be set) A B C D E F G H I Item AUTO Automatic LEVEL1 Manual level 1 LEVEL2 Manual level 2 LEVEL3 Manual level 3 LEVEL4 Manual level 4 LEVEL5 Manual level 5 EXECUTE MODE Print mode PAPER Print execution cassette selection EXIT TRAY Paper exit tray selection Set range Default 1 to 99 1 to 99 1 to 99 1 to 99 1 to 99 1 to 99 1 to 6 *1 1 to 6 *2 1 to 2 *3 50 50 50 50 50 50 1 2 1

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 4

*1

: 1: AUTO 2: LEVEL1 3: LEVEL2 4: LEVEL3 5: LEVEL4 6: LEVEL5 *2: 1: MFT 2: CS1 3: CS2 4: CS3 5: CS4 6: LCC *3 : 1: R 2: S

46

-43 Adjustment Used to adjust the FAX mode (super fine mode) document scan density (when the FAX is installed). ICU PWB/FAX Picture quality

Purpose 46 -42 Adjustment Used to adjust the FAX mode (fine text mode) document scan density (when the FAX is installed). ICU PWB/FAX Picture quality Function (Purpose) Section Item

Purpose Function (Purpose) Section Item

Operation/ 1. Select the print density adjustment mode with the Procedure scroll key. 2. Enter the adjustment value with the 10-key, and press [OK] key. The adjustment value is set. 3. Set the print condition with the scroll key and the 10-key. 4. Set a document and press [EXECUTE] key. The document is scanned at the density level set in procedure 2 and it is printed. (Item to be set)
A AUTO B LEVEL1 C LEVEL2 D LEVEL3 E LEVEL4 F LEVEL5 G AUTO (HALF TONE) H LEVEL1 (HALF TONE) I LEVEL2 (HALF TONE) J LEVEL3 (HALF TONE) K LEVEL4 (HALF TONE) L LEVEL5 (HALF TONE) M EXECUTE MODE N PAPER O EXIT TRAY
*1

Operation/ 1. Select the print density adjustment mode with the Procedure scroll key. 2. Enter the adjustment value with the 10-key, and press [OK] key. The adjustment value is set. 3. Set the print condition with the scroll key and the 10-key. 4. Set a document and press [EXECUTE] key. The document is scanned at the density level set in procedure 2 and it is printed. (Item to be set)
A AUTO B C D E F G H I Item Super fine/ Auto/ Without half-tone LEVEL1 Super fine/ Manual level 1/ Without half-tone LEVEL2 Super fine/ Manual level 2/ Without half-tone LEVEL3 Super fine/ Manual level 3/ Without half-tone LEVEL4 Super fine/ Manual level 4/ Without half-tone LEVEL5 Super fine/ Manual level 5/ Without half-tone AUTO Super fine/ Auto/ With half(HALF TONE) tone LEVEL1 Super fine/ Manual level 1/ (HALF TONE) With half-tone LEVEL2 Super fine/ Manual level 2/ (HALF TONE) With half-tone LEVEL3 Super fine/ Manual level 3/ (HALF TONE) With half-tone LEVEL4 Super fine/ Manual level 4/ (HALF TONE) With half-tone LEVEL5 Super fine/ Manual level 5/ (HALF TONE) With half-tone EXECUTE MODE Print mode PAPER Print execution cassette selection EXIT TRAY Paper exit tray selection Set range Default 1 ­ 99 50 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 12 *1 1 ­ 6 *2 1­2
*3

Item Set range Default Fine text/Auto/ 1 ­ 99 50 Without half-tone Fine text/ Manual level 1/ 1 ­ 99 50 Without half-tone Fine text/ Manual level 2/ 1 ­ 99 50 Without half-tone Fine text/ Manual level 3/ 1 ­ 99 50 Without half-tone Fine text/ Manual level 4/ 1 ­ 99 50 Without half-tone Fine text/ Manual level 5/ 1 ­ 99 50 Without half-tone Fine text/Auto/With half-tone 1 ­ 99 50 Fine text/ Manual level 1/ With half-tone Fine text/ Manual level 2/ With half-tone Fine text/ Manual level 3/ With half-tone Fine text/ Manual level 4/ With half-tone Fine text/ Manual level 5/ With half-tone Print mode Print execution cassette selection Paper exit tray selection 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 12 *1 1 ­ 6 *2 1­2
*3

50 50 50 50 50 50 50 50 50 50 50 1 2 1

50 J 50 K 50 L 50 50 1 2 1 M N O
*1

: 1: AUTO 2: LEVEL1 3: LEVEL2 4: LEVEL3 5: LEVEL4 6: LEVEL5 7: AUTO (HALF TONE) 8: LEVEL1 (HALF TONE) 9: LEVEL2 (HALF TONE) 10: LEVEL3 (HALF TONE) 11: LEVEL4 (HALF TONE) 12: LEVEL5 (HALF TONE) *2: 1: MFT 2: CS1 3: CS2 4: CS3 5: CS4 6: LCC *3 : 1: R 2: S

: 1: AUTO 2: LEVEL1 3: LEVEL2 4: LEVEL3 5: LEVEL4 6: LEVEL5 7: AUTO (HALF TONE) 8: LEVEL1 (HALF TONE) 9: LEVEL2 (HALF TONE) 10: LEVEL3 (HALF TONE) 11: LEVEL4 (HALF TONE) 12: LEVEL5 (HALF TONE) *2: 1: MFT 2: CS1 3: CS2 4: CS3 5: CS4 6: LCC *3 : 1: R 2: S

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 5

46

-44 Adjustment Used to adjust the FAX mode (ultra-fine mode) document scan density (when the FAX is installed). ICU PWB/FAX Picture quality

49
49 -1 Version up Used for firmware version up (Machine/FAX). Firmware (Machine/FAX) Operation

Purpose Function (Purpose) Section Item

Purpose Function (Purpose) Section Item

Operation/ 1. Select the print density adjustment mode with the Procedure scroll key. 2. Enter the adjustment value with the 10-key, and press [OK] key. The adjustment value is set. 3. Set the print condition with the scroll key and the 10-key. 4. Set a document and press [EXECUTE] key. The document is scanned at the density level set in procedure 2 and it is printed. (Item to be set)
A AUTO B C D E F G H I J K L M N O
*1

Operation/ 1. Press the [EXECUTE] key to enter the Flash Procedure ROM writing mode. 2. Start the download program on the PC side and perform Flash ROM writing.

Item Ultra-fine/ Auto/ Without half-tone LEVEL1 Ultra-fine/ Manual level 1/ Without half-tone LEVEL2 Ultra-fine/ Manual level 2/ Without half-tone LEVEL3 Ultra-fine/ Manual level 3/ Without half-tone LEVEL4 Ultra-fine/ Manual level 4/ Without half-tone LEVEL5 Ultra-fine/ Manual level 5/ Without half-tone AUTO Ultra-fine/ Auto/ With half(HALF TONE) tone LEVEL1 Ultra-fine/ Manual level 1/ (HALF TONE) With half-tone LEVEL2 Ultra-fine/ Manual level 2/ (HALF TONE) With half-tone LEVEL3 Ultra-fine/ Manual level 3/ (HALF TONE) With half-tone LEVEL4 Ultra-fine/ Manual level 4/ (HALF TONE) With half-tone LEVEL5 Ultra-fine/ Manual level 5/ (HALF TONE) With half-tone EXECUTE MODE Print mode PAPER Print execution cassette selection EXIT TRAY Paper exit tray selection

Set range Default 1 ­ 99 50 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 99 1 ­ 12 *1 1 ­ 6 *2 1­2
*3

50 50

50
50 50 50 50 50 50 50 50 50 1 2 1

50

-27 Adjustment Used to adjust image loss in the FAX/scanner mode. FAX/Scanner Picture quality Image position

Purpose Function (Purpose) Section Item

Operation/ 1. Select the adjustment mode with the scroll key. Procedure 2. Enter the adjustment value at the selected point, and press the [OK] key. The entered value is set. When the adjustment value is changed, the image losses at the four corners are changed uniformly. Display A B C Min. Max. Default Value Value FAX MODE image loss 0 99 20 PUSH SCAN MODE image loss 0 99 30 PULL SCAN MODE image loss 0 99 0 Content

: 1: AUTO 2: LEVEL1 3: LEVEL2 4: LEVEL3 5: LEVEL4 6: LEVEL5 7: AUTO (HALF TONE) 8: LEVEL1 (HALF TONE) 9: LEVEL2 (HALF TONE) 10: LEVEL3 (HALF TONE) 11: LEVEL4 (HALF TONE) 12: LEVEL5 (HALF TONE) *2 : 1: MFT 2: CS1 3: CS2 4: CS3 5: CS4 6: LCC *3 : 1: R 2: S

66
66 -01 Setting Used to change/set the soft SW setting (FAX-related items). (When the FAX is installed.) FAX

Purpose Function (Purpose) Section

Operation/ 1. Enter the soft SW number to be selected with the Procedure 10-key. 2. Change or set the selected soft SW setting. 3. Enter [EXECUTE] key to save the setting. The FAX-related soft SW setting is displayed on the LCD for checking and changing.

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 6

(Sendable signals)
Page.1: NO SIGNAL (No signal is sent.) 33.6 V34 (3429) 31.2 V34 (3429) 28.8 V34 (3429) 26.4 V34 (3200Low) 24.0 V34 (3200Hi) 21.6 V34 (3200Low) 19.2 V34 (3000Hi) 16.8 V34 (3000Low) 14.4 V34 (3000Hi) 12.0 V34 (2800) 9.6 V34 (2800) 7.2 V34 (2800) 4.8 V34 (2400) 2.4 V34 (2400) 14.4 V33 Page.2: 12.0 V33 14.4 V17 12.0 V17 9.6 V17 7.2 V17 9.6 V29 7.2 V29 4.8 V27t 2.4 V27t 0.3 FLG CED 2100 CNG 1100 0.3 V21 ANSam RINGER No RBT

66

-02 Setting Used to initialize the soft SW setting (FAX-related items) according to the destination. (When the FAX is installed.) FAX Data Initializing

Purpose Function (Purpose) Section Item

Operation/ 1. Enter the destination code with the 10-key, and Procedure press [SET] key. 2. Press the [EXECUTE] key. (YES/NO key display) 3. When [Yes] key is pressed, the soft SW is initialized according to the destination code. (When [No] key is pressed, the operation is canceled. )

The unit of setting is kbps. Setting is made by the key display name. The item in ( ) is, however, excluded.

66

-05 Operation test/check Used to select a signal and send it to the line and the speaker. (Level: Soft SW setting) (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section 66 -03 Operation test/check Used to check the memory on the Modem controller. (When the FAX is installed.) FAX Operation Item Purpose Function (Purpose) Section Item

Operation/ The page can be selected with the scroll keys. Procedure 1. Select the send mode. 2. Press the [EXECUTE] key. (Sendable signals)
Page.1: NO SIGNAL (No signal is sent.) 33.6 V34 (3429) 31.2 V34 (3429) 28.8 V34 (3429) 26.4 V34 (3200Low) 24.0 V34 (3200Hi) 21.6 V34 (3200Low) 19.2 V34 (3000Hi) 16.8 V34 (3000Low) 14.4 V34 (3000Hi) 12.0 V34 (2800) 9.6 V34 (2800) 7.2 V34 (2800) 4.8 V34 (2400) 2.4 V34 (2400) 14.4 V33 Page.2: 12.0 V33 14.4 V17 12.0 V17 9.6 V17 7.2 V17 9.6 V29 7.2 V29 4.8 V27t 2.4 V27t 0.3 FLG CED 2100 CNG 1100 0.3 V21 ANSam RINGER No RBT

Operation/ 1. Press the [EXECUTE] key. Procedure Read/write checks of the EEPROM, the SRAM (G/A), and the SDRAM on the modem controller and the SRAM and the Flash ROM on the MFP controller are executed and the results are displayed.

66

-04 Operation test/check Used to select a signal and send it to the line and speaker (at the max. level). (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section Item

The unit of setting is kbps. Setting is made by the key display name. The item in ( ) is, however, excluded.

Operation/ The page can be selected with the scroll keys. Procedure 1. Select the send mode. 2. Press the [EXECUTE] key.

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 7

66

-06 Data output/check Used to print the check list of the contents when confidential registration is made. (When the FAX is installed.) FAX Data Confidential pass code 66 -09 Operation test/check Used to select a signal and send it to the line and the speaker. (Level: soft SW setting). (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section Item

Operation/ 1. Press the [EXECUTE] key. Procedure The confidential registration check list (Box No., BOX name, and print pass code) is printed. (If there is no registration, print is not made.)

Purpose Function (Purpose) Section Item

Operation/ 1. Select the voice message to be sent. Procedure 2. Press the [EXECUTE] key. (Sendable message) 66 -07 Data output/check Used to print all the images in the memory. (When the FAX is installed.) FAX Data Image data NONE PAUSE MESSAGE1 MESSAGE2 MESSAGE3 MESSAGE4 MESSAGE5 MESSAGE6 ALARM RINGER EXT.TEL.RINGER Mute Hold-on melody Message 1 Message 2 Message 3 Message 4 Message 5 Message 6 Alarm Calling melody (speaker) External telephone call

Purpose Function (Purpose) Section Item

Operation/ 1. Press the [EXECUTE] key. Procedure All the image data saved in the image memory are outputted. The confidential receive data are also outputted.

66

-08 Operation test/check Used to select a voice message and send it to the line and the speaker (at the max. level). (When the FAX is installed.) FAX Operation

66

-10 Data clear All the images in the memory can be deleted. (When the FAX is installed.) FAX Data Image data

Purpose Function (Purpose) Section Item

Purpose Function (Purpose) Section Item

Operation/ 1. Select the voice message to be sent. Procedure 2. Press the [EXECUTE] key. (Sendable message) NONE PAUSE MESSAGE1 MESSAGE2 MESSAGE3 MESSAGE4 MESSAGE5 MESSAGE6 ALARM RINGER EXT.TEL.RINGER Mute Hold-on melody Message 1 Message 2 Message 3 Message 4 Message 5 Message 6 Alarm Calling melody (speaker) External telephone call

Operation/ 1. Press the [EXECUTE] key. Procedure All the image data saved in the image memory are deleted. Confidentially received data are also deleted.

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 8

66

-11 Operation test/check Used to select a pattern and send it to the line and the speaker at 300bps (at the max. level). (When the FAX is installed.) FAX Operation

66

-13 Setting Used to register a dial number for test used in SIM 66-14/15/16. (When the FAX is installed.) FAX Data Registration

Purpose Function (Purpose) Section Item

Purpose Function (Purpose) Section Item

Operation/ 1. Select the pattern to be sent. Procedure 2. Press the [EXECUTE] key. (Sendable voice message) NO SIGNAL 00000 11111 10101 11110 00001 No signal (CML ON) Repetition of "00000" Repetition of "11111" Repetition of "10101" Repetition of "11110" Repetition of "00001"

Operation/ If a dial number is already registered, it is displayed Procedure on "PRESENT: ." 1. Enter a dial number with the 10-key (displayed on NEW:) and press [SET] key. The registered number is displayed on "PRESENT:."

66

-14 Adjustment Used to adjust and check the make time of dial pulse (10pps). (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section 66 -12 Purpose Function (Purpose) Section Item Operation test/check Used to select a pattern and send it to the line and the speaker at 300bps. (Level: soft SW setting) (When the FAX is installed.) FAX Operation A Item

Operation/ 1. Enter the make time to be set with the 10-key. Procedure 2. Press [OK] key to set. 3. Press [EXECUTE] key to send the pulse (dial set with SIM 66-13). (Items to be set) Item Make time Set range 0 ­ 15 Default 11 (Europe) 6 (Australia, New Zealand)

Operation/ 1. Select the pattern to be sent. Procedure 2. Press the [EXECUTE] key. (Sendable voice message) NO SIGNAL 00000 11111 10101 11110 00001 No signal (CML ON) Repetition of "00000" Repetition of "11111" Repetition of "10101" Repetition of "11110" Repetition of "00001"

66

-15 Adjustment Used to adjust and check the make time of the dial pulse (20pps). (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section Item

Operation/ 1. Enter the make time to be set with the 10-key. Procedure 2. Press [OK] key to set. 3. Press [EXECUTE] key to send the pulse (dial set with SIM 66-13). (Items to be set) A Item Make time Set range 0 ­ 15 Default 8

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 9

66

-16 Adjustment Used to adjust and check the send level of DTFM signal. (When the FAX is installed.) FAX Operation

66

-19 Backup Used to write the ICU PWB SRAM contents (various set values and user data) into the Flash ROM (ARMM9). (When the FAX is installed.) FAX Data

Purpose Function (Purpose) Section Item

Purpose Function (Purpose) Section Item

Operation/ 1. Select an item to be adjusted with the scroll key. Procedure 2. Enter the set value with the 10-key. 3. Press [OK] key to set. 4. Press [EXECUTE] key to send pulses (dial set with SIM 66-13) from the line at each setting of the high group and the low group of the send level. (Adjustable items) Item A Level (db) B Difference between the high and the low groups Set range 0 ­ 15 0 ­ 15 Default 5 1

Operation/ 1. Press the [EXECUTE] key. (YES/NO key display) Procedure 2. Press [Yes] key to write the ICU PWB SRAM data into the Flash ROM (AR-MM9). This function is enabled only when the AR-MM9 is installed. It is used when the ICU PWB SRAM data must be backed up in case of repair of the ICU PWB, etc.

66

-20 Backup Used to write the Flash ROM (AR-MM9) contents (SRAM contents written with SIM 66-19) into the ICU PWB SRAM. (When the FAX is installed.) FAX Data

Purpose Function (Purpose) 66 -17 Operation test/check Used to select the DTFM signal (1 ­ 9, 0, *, #) to send it to the line and the speaker (at the max. level). (When the FAX is installed.) FAX Operation Section Item

Purpose Function (Purpose) Section Item

Operation/ 1. Press the [EXECUTE] key. (YES/NO key Procedure display) 2. Press [Yes] key to write the Flash ROM (ARMM9) data into the ICU PWB SRAM. This function is enabled only when the AR-MM9 is installed. It is used to restore the backup data of the AR-MM9 to the ICU PWB SRAM after completion of repair of the ICU PWB.

Operation/ 1. Select the DTFM signal (1 ­ 9, 0, *, #) to be sent. Procedure 2. Press the [EXECUTE] key.

66 66 -18 Operation test/check Used to select the DTFM signal (1 ­ 9, 0, *, #) to send it to the line and the speaker (Level: soft SW setting). (When the FAX is installed.) FAX Operation Purpose Function (Purpose) Section Item

-21 Check Used to print various registration information, communication, file management, system error, and protocol information. (When the FAX is installed.) FAX Data

Purpose Function (Purpose) Section Item

Operation/ 1. Select the DTFM signal (1 ­ 9, 0, *, #) to be sent. Procedure 2. Press the [EXECUTE] key.

Operation/ 1. Select items to be printed. Procedure 2. Press the [EXECUTE] key. (Printable data) REGISTERED MANAGEMENT FILE MANAGEMENT SYSTEM ERROR PROTOCOL Various registration information Communication management information File management information System error information Protocol information

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 10

66

-29 Data clear Used to clear the data related to the address book (one-touch registration, program registration/ expansion, interface memory box registration, each table contents). (When the FAX is installed.) FAX Data Initializing

Purpose Function (Purpose)

Section 66 -22 Setting Used to set the sound volume of the handset. (When the FAX is installed.) FAX Operation Item

Purpose Function (Purpose) Section Item

Operation/ 1. Press the [EXECUTE] key. (YES/NO key Procedure display) 2. Press [Yes] key to clear the data stored in the FAST memory. (Press [NO] key to cancel.)

Operation/ 1. Select the sound volume. (MIN: Minimum, Procedure MIDDLE: Middle, MAX. Maximum) 2. Press the [EXECUTE] key.

66

-30 Operation test/check Used to check the status change of the TEL/LIU sensor. (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section 66 -23 Setting Used to download the FAX program. (When the FAX is installed.) FAX Operation Item Purpose Function (Purpose) Section Item

Operation/ Each display is reversed or normalized according to Procedure the status change. (Checkable sensors) HS1 HS2 RHS EXHS Polarity reverse signal Polarity reverse signal Handset hook SW External telephone hook SW

Operation/ 1. Press the [EXECUTE] key. Procedure The FAX program is downloaded.

66

-24 Data clear Used to clear the data in the FAST memory. (When the FAX is installed.) FAX Data Initializing

66

-31 Setting Used to set ON/OFF of each port for output to the TEL/LIU. (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section Item

Purpose Function (Purpose) Section Item

Operation/ 1. Press the [EXECUTE] key. (YES/NO key Procedure display) 2. Press [Yes] key to clear the data stored in the FAST memory. (Press [NO] key to cancel.)

Operation/ 1. Press the [EXECUTE] key. (ON: Reverse Procedure display) 2. Press the [EXECUTE] key. (Setting is saved.) (Settable ports) MPXA CION MR EC S CML DP

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 11

66

-35 Setting Used to rewrite the Modem program. (When the FAX is installed.) FAX Data Writing

Purpose Function (Purpose) Section Item 66 -32 Operation test/check Used to check (compare) the received data (fixed data) from the line to make judgment of error or normal. (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section Item

Operation/ 1. Press the [EXECUTE] key. (YES/NO key Procedure display) 2. Press [Yes] key to rewrite the Modem program. (Press [NO] to cancel.) 3. Check sum is executed and the write result is displayed. (Check sum result display) COMPLETE 81 82 83 84 NG : Write complete : Check sum error : Write error : Delete error : Verify error : Because of LOADER NG

Operation/ The fixed data received from the line are checked Procedure and the result is displayed. Coincide: OK is displayed. / Not coincide: NG is displayed.

66

-33 Operation test/check Used to detect signals (BUSY TONE/CNG/CED/ FNET) from the line. (When the FAX is installed.) FAX Operation

Purpose Function (Purpose) Section Item

66

-36 Operation test/check Used to check send/receive (data/command line) from the Modem controller to the MFP controller. (When the FAX is installed) FAX Operation

Purpose Function (Purpose) Section Item

Operation/ Various signals are detected with the line Procedure connected. The detected signals are highlighted.

Operation/ 1. Press [EXECUTE] key to check send and receive Procedure operation of the data line or the command line individually from the Model controller to the MFP controller.

66

-34 Operation test/check Used to display the time required for sending the test image data. (When the FAX is installed.) FAX Operation 66 -39 Setting Used to set the destination of the FAX. (When the FAX is installed.) FAX Specifications Purpose Function (Purpose) Section Item

Purpose Function (Purpose) Section Item

Operation/ The send test is executed, and the time to send the Procedure image data in that test communication is measured and displayed. Send/receive are executed in the normal mode, and the measure communication time (ms) is displayed.

Operation/ Press the key corresponding to the destination to set. Procedure The set information is saved in the EEPROM in the FAX unit. If no setting is made, "NO DESTINATION" is displayed.

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 12

6. FAX software switch
A. Soft SW setup change quick reference
Large item Dial (Calling) Medium item Content of switch Remote Line current detection in dial call machine Dial call wait time calling disable Pause time (between dialing) Tone/Pulse default setup (Dial call signal) DTMF signal level (high group) DTMF send level (low group) DTMF signal send time DTMF minimum pause time Make time (10PPS) Break time (10PPS) Minimum pause (10PPS) Busy tone detection Busy tone detection cycle DT/BT detection level Dial tone detection Dial tone monitor time Busy tone detection time lower limit (ON time) Busy tone detection time upper limit (ON time) DT/BT detection frequency range setup Recalling when the remote machine does not respond. Number of recall in communication error Setup of reference for the number of recall in communication error Recall allowed in communication error Recall interval in communication error Recall interval in communication busy Number of recall in busy Recall allowed in busy Auto reception call number setup Auto/Manual default setup CI detection disable Call signal ON time lower limit Call signal ON time upper limit Call signal OFF time lower limit Call signal OFF time upper limit Call signal OFF not-detection time External telephone connection Send setup Send setup Send setup Send setup Send setup Send setup Send setup Receive setup User setup Key operator Soft SW No. SW 70-5 SW 62-1~2 Initial setup SW 70-1~4 Initial setup SW 62-5~6 Purpose of use Dial disable Dial disable/Erroneous dialing Dial disable/Erroneous dialing Dial disable

Signal detection

SW 66-5~8 Dial disable in PB (PB/FAX service, etc.) SW 67-1~4 Dial disable in PB (PB/FAX service, etc.) SW 68-1~5 Dial disable in PB (PB/FAX service, etc.) SW 69-1~8 Dial disable in PB (PB/FAX service, etc.) SW 63-1~4 Dial disable in pulse SW 63-5~8 Dial disable in pulse SW 64-1~4 Dial disable in pulse SW 71-3 Busy tone detection disable SW 71-4~5 Busy tone detection error SW 71-6~7 Busy tone detection disable SW 70-6 Dial tone detection disable SW 70-7 Dial tone detection error SW 72-1~2 Busy tone detection error SW 72-3 Busy tone detection error

Redial

Remote machine not responding Error Error Error Error Busy Busy Busy Not receiving

SW 72-4~5 Dial tone/busy tone detection error SW 56-8 No recall wanted when remote machine not responding SW 57-5~8 Effective only when divided with SW59-1 SW 59-1 Use of different recall numbers between when busy and when error SW 59-3 SW 2-1~4 SW 57-1~4 SW 58-1~4 SW 59-2 SW 3-5~8 Number of reception call SW 7-2 SW 75-1~4 SW 75-5~8 SW 76-1~4 SW 76-5~6 SW 77-1~4 SW 3-2 Initial setup of auto reception/ manual reception CI signal detection disable CI signal detection disable Ci signal detection disable CI signal detection disable CI signal detection disable External telephone connection

Reception (Calling)

External telephone handset

External telephone connection External telephone offhook detection Remote switch number Remote switch setup

Initial setup

External telephone off-hook detection time Remote switch number setup Remove reception command External telephone notification in remote switching Remote switch enable Initial setup

SW 12-1~8 External telephone off-hook detection error SW 13-1~8 Remote switch detection error SW 14-1 SW 14-2 SW 14-3 Remote switch inhibit

Remote switch is made when calling from external telephone.

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 13

Large item Medium item Content of switch Communication General Signal send level ECM (Other than V.34 mode)

SG3

Timer setup between flag-adrs (V.21-FSK) Send/receive coding capacity (Except for V.34) V.34 mode function V.34 Symbol Rate Mask (when receiving) V.34 mode function in manual communication Countermeasures against echo in sending CED detection time V.34 mode send speed Echo suppresser tone Modem send speed (Except for V.34) DCS-TCF interval time DIS reception confirmation (G3 transmission) Error process in RTN reception

Key operator Soft SW No. Purpose of use Adjustment SW 15-5~8 When the remote machine does not value receive signals in a proper level. Initial setup SW 17-5 Error resend frequently occurs, resulting in extended communication time. SW 20-3~4 Communication error in a satellite line SW 17-7~8 Error in JBIG mode SW 43-1 Frequent errors in SG3 communication SW 43-3~6 Frequent errors in SG3 communication SW 42-8 Frequent errors in SG3 communication in FAX service SW 20-7 An error occurs in phase B.

Send

G3/SG3

SG3 G3

SW 25-5 CED signal detection error SW 44-1~4 An error occurs in SG3 communication. SW 27-1~4 An error occurs in V.29 communication SW 16-1~4 To uncertain/certain receiver SW 24-1 An error occurs in training. SW 20-2 An error occurs in phase B. SW 30-2 OK is displayed when RTN is received.

Receive

G3/SG3 SG3 G3

CSI send V.34 mode reception speed Countermeasures against echo in reception (CED tone send interval) Modem speed fixed in reception (other than V.34) EOL detection timer RTN send line error rate EQM judgment in TCF reception confirmation TCF reception confirmation judgment method Sub scan length judgment Output tray setup Reception data print condition setup Auto reduction/Dispose setup magnification ratio setup in auto reduction Reduction/Dispose setup in printing A3-11x17 Duplex reception print Rotation print Received document output setup in reception Reception width setup of 11 x 17 paper Reception size setup (Indicate reception capacity.) Receive setup Receive setup Receive setup Receive setup

SW 20-1 SW 44-5~8 An error occurs in SG3 communication. SW 20-6 An error occurs n phase B in reception. SW 16-5~6 Fall back or an error occurs due to poor line conditions. SW 23-1 EOL time up occurs frequently. SW 23-7~8 Line error occurs frequently. SW 24-2 TCF reception error occurs. SW 24-3 SW 35-2 TCF reception error occurs.

Receive print

Paper selection

Print is not made on the selected paper. SW 83-1~2 Print is not made on the selected paper. SW 35-3~4 To make divided print instead of reduction print. SW 35-7 To disable reduction print.

SW 36-1~8 To disable reduction print on fixed size paper. SW 35-8 Print is not made on the selected paper when A3-11x17 size document is received. SW 34-8 To make duplex print of received document SW 35-1 To disable rotation print SW 35-5 To print after reception of each page To print 11x17 document as B4 width SW 37-1~2 To limit the reception size. SW 37-3

AR-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 6 - 14

B. Details
UK = U.K., SW Bit Item No. No. 1 1-8 Country code FR = France, GR = Germany, SW = Sweden, AS = Australia, NZ = New Zealand Key operator Switch selection and function Country code set by ITU-T. Control is made according to the set country code. UK FR GR SW AS NZ Initial value 1 0 1 1 0 1 0 0 0 0 0 1 0 0 0 1 0 1 0 0 1 1 1 1 0 1 0 0 0 1 1 0 0 1 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 1 0 1 1 0 1 0 0 1 0 1 0 0 0 1 0 0 0 1 0 1 0 0 0 0 1 0 0 1 0 0 0 1 0 0 0 1 0 1 0 1 1 1 1 1 1 0 0 1 min 0 0 1 0 0 0 1 0 1 YES

2

1-4 Recall interval in case of a communication error

Used to set the recall interval in case of a communication error. The set range is 1 ­ 15min in the increment of 1min by binary input. If a value outside the setup range for each destination is inputted, the default setup is made. Valid except for Australia, and New Zealand.

Send setup

5-8 Not used

3

1 2

Not used External telephone connection

Setting to use an external telephone. If not set to YES, an external telephone cannot be used. 1: External telephone YES 0: External Telephone NO

Initial setup

3,4 Not used 5-8 Number of calls for auto receives Used to set the number of calls to start auto receive (to catch the line). Setup is made in the range of 0 ­ 15 by binary input. When set to 0, no ringing is made.

4

1,2 Not used 3 Polling protection Used to set Enable/Disable of confidential protection (inhibition of transmission to erroneous party) in transmission of bulletin board. Confidential protection is made by collating the number registered in this machine and that in the other party machine. Sender's number and send request allow number are collated each other. In this machine, Sharp's unique collating of system number ID number is not performed. 1: Not protected 4 0: Protected

0 0 0 0 1 0 0 0 0

0 0 0 0 1 0 0 0 0

0 0 0 0 1 0 0 0 0

0 0 0 0 1 0 0 0 0

0 0 0 0 1 0 0 0 0

0 0 0 2 0 1 0 0 0 0 Protect

Receive setup

Polling security setup

Relay data output Used to set whether the document received from the relay station is outputted or not when relay broadcast reception is made. Similar to F code relay broadcast indicating reception. 1: Document received 0: Document received from relay station is not from relay station is outputted. outputted.

0

0

0

0

0

0 Output

5 6

Not used F code relay Used to set whether relay broadcast transmission is broadcast function made by receiving F code relay broadcast instruction from the other party or F code relay broadcast instruction is not re