Text preview for : TPC GZM-60-XS.pdf part of TOPPOWER TPC/GZM-60-T05D15 AC input :176VAC-264VAC overload,over-voltage,short circuit protection Operating temperature:0℃~50℃ RoHS complaint High reliability,effificency No fans Triple output 160*99*38mm SELECTION GUIDE Part Number Input Output Efficiency @25℃, (Typ)% Ripple (mV p-p), @0℃~50℃ Volatge(VAC) Voltage(VDC) Rated current(A) Rated Range values TPC/GZM-60-T05D15 220 176-264 +5/+15/-15 7/0.5/0.5 68 ≤80,≤150,≤150 All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.



Back to : TPC GZM-60-XS.pdf | Home

TPC/GZM-60-T05D15
DESCRIPTION 60W Wide input Triple output AC/DC switching power supply
The rated output power of TPC/GZM-60-T05D15 is 60Winput voltage range176-264VAC, output voltage :
5/±15VDC ,High reliability&effificency ,long-life , with short circuit, overload protection, Widely used in
instrument, telecommunications, industrial control, data acquisition, signal control , New Energy, Security,and
other electronic systems.


FEATURES
AC input 176VAC-264VAC overload,over-voltage,short circuit protection Operating temperature0~50

RoHS complaint High reliability,effificency No fans

Triple output 160*99*38mm

SELECTION GUIDE
Input Output
Ripple
Efficiency
Part Number VolatgeVAC) (mV p-p),
@25, Typ%
VoltageVDC) Rated currentA @0~50
Rated Range values
TPC/GZM-60-T05D15 220 176-264 +5/+15/-15 7/0.5/0.5 68 80,150,150
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
OUTPUT CHARACTERISTICS
Conditions Conditions Parameter

Output power Total peak output power(Sustainable time 5 S) 70W Max
5V (V1) +15V (V2) -15V (V3)
Peak output current
8A 1A 1A
5V (V1) +15V (V2) -15V (V3)
Rated output power
35W 7.5W 7.5W
5V (V1) +15V (V2) -15V (V3)
Output light load setting range @25°C
5.00~5.05V / /
Output voltage range 4.5-5.5V / /
Dynamic load characteristics@0~50 0.7A~3.5A:Vp-p<±350mV 0.7A~7A: Vp-p<±500mV 3.5A~7A: Vp-p<±350mV
Voltage regulation accuracy@0~50 ±1.0% /V1,±5.0% /V2,±5.0% /V3
Line regulation @0~50 ±1.0%
Load regulation @0~50 ±1.0% /V1,±5.0% /V2,±5.0% /V3
Set-up risetime@25 1.2s/220VAC at 100%load
Hold-up time@25 130ms/230VAC at V1/0.2AV2/0.2AV3/0.4A
Overshoot Voltage@0~50 <5%


INPUT CHARACTERISTICS
Conditions Parameter
Input voltage range 176Vac~264Vac
Rated input voltage range 200Vac~240Vac
Frequency Range 47Hz~63Hz
Set-up Voltage 176Vac
Input current @25 <0.9 A
Inrush current @25 Cold Start <40A@220Vac




www.gztoppower.com TEL:0086-20-82019000 Email:[email protected] Page1 / 4
TPC/GZM-60-T05D15
PROTECTION @-20~65
Conditions Parameter Notes
protection mode: swinging machine, automatic recovery after eliminating over power; over power
Over-power 65W~95W swinging machine
protection point is V1, V2, V3 output total The sum of the powers, P = V1 * I1 + V2 * I2 + V3 * I3)

Output current continues to increase until protection;Protection mode: Swing machine, can
Over-current [email protected],[email protected],[email protected]
automatically resume normal work after eliminating overcurrent.


short circuit Long-term short circuit, automatic recovery after Long-term short circuit, automatic recovery short eliminating short circuit (V2, V3 can not be
eliminating short circuit (V2, V3 can not be after circuit)
shorted)


ENVIRONMENT CHARACTERISTICS
Conditions Parameter
Operating amb. Temp.&Humi. 0~50; 20%~90%RH refer to the derating curve
Storage Temp. & Humi. -25~85, 10%~95%RH
Altitude 3000m
Temperature coefficient @0~50 0.03%



SAFETY&EMC STANDARDS @25
Conditions Parameter

Safety Standards GB4943/EN60950 (for reference)

Isolation Voltage I/P-O/P:3Kvac/10mA I/P-FG : 1.5Kvac/10mA O/P-FG :0.5Kvac/10mA test time:1min

Leakage current @25°C I/P-FG :3.5MA I/P-O/P0.25MA

Isolation resistance I/P-O/P: I/P-FG : O/P-FG : 100M ohms/500VDC 25 65% RH

Grounding test Test condition32A1min.Grounding resistance0.1 ohms.

ESD EN61000-4-2 LEVEL3

EFT EN61000-4-4 LEVEL3

Interrupted EN61000-4-11

Surge EN61000-4-5 LEVEL4

OTHERS

Conditions Parameter

Cooling method Cooling by free air flow

Dimension (L*W*H) 160*99*38mm

RELIABIILITY CHARACTERISTICS
Conditions Parameter

MTBF 200000Hrs MIL-217 Method 2 Components Stress Method

Design electrolytic capacitor life 35,687Hrs AT 25 FULL Load and Units Continuously Working

NOTES
1. The expected output power can reach 57W, and the pre-output current can reach 8.4A.

2. Ripple noise is connected by 12# twisted pair. The oscilloscope bandwidth is set to 20MHz. Tektronix P3010 100M bandwidth probe is used, and 0.1uF polypropylene
capacitor and 10uF electrolytic capacitor are connected in parallel on the probe end. The oscilloscope sampling uses Sample sampling mode.

3.The derating should be carried out at low voltage input or when working in a high temperature environment. For more details, please refer to the derating curve.

4.Minimum load requirement: [email protected] [email protected] [email protected]

www.gztoppower.com TEL:0086-20-82019000 Email:[email protected] Page2 / 4
TPC/GZM-60-T05D15
MECHANICAL DIMENSIONS


Unit: mm




www.gztoppower.com TEL:0086-20-82019000 Email:[email protected] Page3 / 4
TPC/GZM-60-T05D15
Internal block diagram:




DERATING CURVE




MODEL SELECTION


TP C / GZM - 60 ­ T 05D15
Ouput voltage
Triple output

Delimiter
Rated output Power

Delimiter

Series
Delimiter

Type

Brand
TOPPOWER




www.gztoppower.com TEL:0086-20-82019000 Email:[email protected] Page4 / 4