DESCRIPTION 6W 1.5KVDC3KVDC Isolated Wide Input Voltage DC/DC Converters
The rated output power of TP06DA converters is 6W,the outline dimensions is "31.75*20.32*11.2", 2:1 and 4:1 wide
input Voltage range, the voltage range is 4.5-9V,9V-18V,18V-36V,36V-72V,9V-36V and 18V-72VDC.The accuracy of
the converter can reach ±1% it can be widely used in telecommunications, railway transportation, instrument and etc.


FEATURES
6W output power 2:1 and 4:1 wide input voltage range Over load protection
31.75mm*20.32mm*11.2mm standard package Fixed switching frequency Operating temperature: -40to 85
Metal shell package or plastic shell packaging RoHS compliant 1.5KVDC3KVDC isolation

SELECTION GUIDE
Input Voltage Output
Maxmum capacitive
voltageVDC) Efficiency(Typ)
Part Number load
VoltageVDC) CurrentA % u F)
Rated Range values
TP06DA05S05 5(2:1) 4.5-9 5 1.2 79 1500
TP06DA05S12 5(2:1) 4.5-9 12 0.5 82 660
TP06DA05D05 5(2:1) 4.5-9 ±5 ±0.6 79 850
TP06DA12S03 12(2:1) 9-18 3.3 1.5 77 2200
TP06DA12S05 12(2:1) 9-18 5 1.2 79 1500
TP06DA12S12 12(2:1) 9-18 12 0.5 82 660
TP06DA12S15 12(2:1) 9-18 15 0.4 84 470
TP06DA12D05 12(2:1) 9-18 ±5 ±0.6 79 850
TP06DA12D12 12(2:1) 9-18 ±12 ±0.25 82 330
TP06DA12D15 12(2:1) 9-18 ±15 ±0.2 84 220
TP06DA24S03 24(2:1) 18-36 3.3 1.5 78 2200
TP06DA24S05 24(2:1) 18-36 5 1.2 80 1500
TP06DA24S12 24(2:1) 18-36 12 0.5 84 660
TP06DA24S15 24(2:1) 18-36 15 0.4 86 470
TP06DA24S24 24(2:1) 18-36 24 0.25 83 470
TP06DA24D05 24(2:1) 18-36 ±5 ±0.6 81 850
TP06DA24D12 24(2:1) 18-36 ±12 ±0.25 84 330
TP06DA24D15 24(2:1) 18-36 ±15 ±0.2 86 220
TP06DA48S03 48(2:1) 36-72 3.3 1.5 78 2200
TP06DA48S05 48(2:1) 36-72 5 1.2 80 1500
TP06DA48S12 48(2:1) 36-72 12 0.5 84 660
TP06DA48S15 48(2:1) 36-72 15 0.4 86 470
TP06DA48D05 48(2:1) 36-72 ±5 ±0.6 80 850
TP06DA48D12 48(2:1) 36-72 ±12 ±0.25 84 330
TP06DA48D15 48(2:1) 36-72 ±15 ±0.2 83 220
TP06DA24S05W 24(4:1) 9-36 5 1.2 80 1500
TP06DA24S12W 24(4:1) 9-36 12 0.5 82 660
TP06DA24S15W 24(4:1) 9-36 15 0.4 84 470
TP06DA24D05W 24(4:1) 9-36 ±5 ±0.6 80 850
TP06DA24D12W 24(4:1) 9-36 ±12 ±0.25 82 330
TP06DA24D15W 24(4:1) 9-36 ±15 ±0.2 84 220
TP06DA48S03W 48(4:1) 18-72 3.3 1.5 78 2200
TP06DA48S05W 48(4:1) 18-72 5 1.2 77 1500
TP06DA48S12W 48(4:1) 18-72 12 0.5 80 660
TP06DA48S15W 48(4:1) 18-72 15 0.4 84 470
TP06DA48D05W 48(4:1) 18-72 ±5 ±0.6 80 850
TP06DA48D12W 48(4:1) 18-72 ±12 ±0.25 82 330
3KVDC isolation with /3H at the end of the part number. for example TP06DA24S05W/3H ;3KVDC isolated parts only can make with plastic shell packaging.
TP06DA48D15W 48(4:1) 18-72 ±15 ±0.2 79 ±47

www.gztoppower.com TEL0086-20-62162688 [email protected] page 1 of 4
TP06DA Series
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.

GENERAL CHARACTERISTICS
parameter Test conditions Min Typ Max Units
Isolation voltage Input to Output 500 15003000 VDC
Isolation resistance Input to Output 100M ohm
Seismic 10~55Hz 5 G
5
MTBF MIL-HDBK-217F2 5 x 10 hrs
Over-current protection mode Full input range Auto recovery
Cooling Free air convection
Case material Metal case

INPUT CHARACTERISTICS
parameter Test conditions Min Typ Max Units
Startup voltage 5V Input module(4.5V -9V) 4.9 5 5.15
Startup voltage 12V Input module(9V -18V) 8.8 9 9.3 VDC
Startup voltage 24V Input module(18V-36V) 18 VDC
Startup voltage 48V Input module(36V-72V ) 36 VDC
Startup voltage 24V Input module(9V -36V) 8.8 9 9.3 VDC
Startup voltage 48V Input module(18V-72V) 18 VDC
Start rising time Input rising time from 5%-100% 20 ms
OUTPUT CHARACTERISTICS
parameter Test conditions Min Typ Max Units

Voltage accuracy Io=0.1...1.0 x Ionom Vi=Vi rated ±1 %

Line regulation ViminViVimax ±0.2 %
Io=0.1...1.0 x Ionom
Load regulation ±0.5 %
Vimin ViVimax
Main Load and auxiliary load differ 25%,the
Auxiliary voltage accuracy auxiliary circuit of the load with at least 25%, the ±3 %
main circuit with full load
Ripple and noise 20MHz bandwidth ±1 %
Over-current protection ViminViVimax 120 %
Transient recovery time 25% load change ±5 %
Transient overshoot range 25% load change 400 us
Switch frequency ViminViVimax 300 KHz

ENVIRONMENT CHARACTERISTICS
parameter Test conditions Min Typ Max Units
Storage Humidity Non condensing 5 +95 %
Operating Temperature Power derating (above 71 -40 +85
Storage Temperature -55 +125
Max. Case Temperature Operating Temperature curve range 105
Lead Temperature 1.5mm from case for 10 seconds 300
Cooling Free air convection


Case temperature under shall not exceed the maximum case temperature level.




www.gztoppower.com TEL0086-20-62162688 [email protected] page 2 of 4
TP06DA Series
MECHANICAL DIMENSIONS PIN CONNECTIONS

DIP Package
Pin Single Output Dual Output
31.75
2 -Vin -Vin
3 -Vin -Vin
2 3 9 10 11
(9) (11) 9 NC

20.32 15.24 bottom view 9 / Com
10 NC NC
(16)
23 22 16 15 14 11 NC
11 / -Vout
2.54 2.54 14 +Vout +Vout
15 NC NC
16 -Vout /

11.20
16 / Com
0.50 22 +Vin +Vin
23 +Vin +Vin

1.00
4.00
4.57 17.78 5.08




Units: mm
Tolerance: ±0.2mm

MODEL SELECTION

TP 06 D A 24 S 05 W

W:4:1 Wide voltage input range
Output voltage

S:single output D:Dual output
Input Rated Voltage

Package type
DC-DC
Output rated power
Brand name

RECOMMEND CIRCUIT:
Single Output

+ vin + V0


+ +
Cin DC-DC Cout

-vin -V0




www.gztoppower.com TEL0086-20-62162688 [email protected] page 3 of 4
TP06DA Series
RECOMMEND CIRCUIT:
Dual Output


+ vin + V0

+
Cout1
+ COM
Cin DC-DC
+
Cout2
-vin -V0




Add input capacitance Cin is helpful to improve the electromagnetic compatibility, recommend Cin use 47 uF-100uF of the electrolytic capacitors.
If the module connect to the digital circuits, please add the CoutCout1Cout2.
If Cout, Cout1, Cout2 value is too high or lower ESR, it will cause the module instable,
The recommended value of Cout, Cout1, Cout2 should be 100 uF/A, the current here means the output current.




USING ATTENTIONS


Module will cause irreversible damage when in the state of the input reverse polarity.
Module will cause irreversible damage when in the long-term overload conditions.
Module will cause irreversible damage when out of the maximum input voltage range.




STEMPERATURE DERATING GR




www.gztoppower.com TEL0086-20-62162688 [email protected] page 4 of 4