TP100~200DH Series
DESCRIPTION 100W~200W 1.5KVDC Isolated Wide Input Voltage DC/DC Converters
The rated output power of TP100DH converters is 100W, TP150DH converters is 150W, TP200DH converters is
200W ,the outline dimensions is 57.9*61*12.7mm,with 2:1, input voltage range ,the voltage range is 9V-18V,
18V-36V,36V-72V.The accuracy of the converter can reach ±1%,it can be widely used in telecommunications,
railway transportation, instrument and etc.


FEATURES
100W -200W output power 2:1 input voltage range Input under voltage protection
standard package Fixed switching frequency Super capability with capacitive load




R
Long term short-circuit protection Operating temperature: -40to 85 RoHs compliance

SELECTION GUIDE
Input Voltage Output
Efficiency




E
Capacity
Part Number voltageVDC) Voltage Current Ability Typ.
VDC) A (uF) (%)
Rated Range values
TP100DH12S12 12(2:1) 9-18 12 8.3 2200 84
TP100DH12S15 12(2:1) 9-18 15 6.6 2200 87




W
TP100DH24S05 24(2:1) 18-36 5 20 10000 87
TP100DH24S12 24(2:1) 18-36 12 8.3 2200 84
TP100DH24S15 24(2:1) 18-36 15 6.6 2200 87




O
TP100DH24S24 24(2:1) 18-36 24 4.1 1000 88
TP100DH48S05 48(2:1) 36-72 5 20 10000 87




P
TP100DH48S12 48(2:1) 36-72 12 8.3 2200 84
TP100DH48S15 48(2:1) 36-72 15 6.6 2200 87
1000




P
TP100DH48S24 48(2:1) 36-72 24 4.1 88
TP100DH48S48 48(2:1) 36-72 48 2.1 470 88
TP150DH24S05 24(2:1) 18-36 5 30 10000 87
2200




O
TP150DH24S12 24(2:1) 18-36 12 12.5 87
TP150DH24S15 24(2:1) 18-36 15 10 2200 85
TP150DH24S24 24(2:1) 18-36 24 6.2 1000 85




T
TP150DH48S05 48(2:1) 36-72 5 30 10000 87
TP150DH48S12 48(2:1) 36-72 12 12.5 2200 87
TP150DH48S15 48(2:1) 36-72 15 10 2200 85
TP150DH48S24 48(2:1) 36-72 24 6.2 1000 85
TP150DH48S48 48(2:1) 36-72 48 3 470 85
TP200DH48S05 48(2:1) 36-72 5 40 10000 84
TP200DH48S12 48(2:1) 36-72 12 16.7 2200 84
TP200DH48S24 48(2:1) 36-72 24 8.3 1000 87
TP200DH48S48 48(2:1) 36-72 48 4.2 470 87


All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified
GENERAL CHARACTERISTICS
parameter Test conditions Min Typ Max Units
Isolation voltage Input to output 500 1500 VDC
Insulation resistance Input to output 100M Ohm
Seismic 10~55Hz 5 G
MTBF MIL-HDBK-217F2 2x106 hrs
Over-current protection mode All input range Burp, Automatic recovery


www.gztoppower.com TEL0086-20-62162688 [email protected] page 1 of 3
TP100~200DH Series
INPUT CHARACTERISTICS
parameter Test conditions Min Typ Max Units
Voltage(21) The12V input module 9 12 18 VDC
Voltage(21) The24V input module 18 24 36 VDC
Voltage(21) The48V input module 36 48 72 VDC
OUTPUT CHARACTERISTICS
parameter Test conditions Min Typ Max Units

Voltage accuracy Io=0.1...1.0 x Ionom Vi=Vi rated ±1 %

Line regulation ViminViVimax ±0.2 %

Load regulation Io=0.1...1.0 x Ionom ,Vimin ViVimax ±0.5 %




R
Main Load and auxiliary load differ 25%,the auxiliary circuit of the
Auxiliary voltage accuracy ±3 %
load with at least 25%, the main circuit with full load




E
Ripple and noise 20MHz bandwidth 50 300 mV
Transient recovery time 25% load changes ±5 %
Transient overshoot time 25% load changes 400 us
Switch frequency ViminViVimax 300 KHz




W
ENVIRONMENT CHARACTERISTICS
parameter Test conditions Min Typ Max Units




O
Storage Humidity Non condensing 5 +95 %
Operating Temperature Power derating (above 71 -40 +85
Storage Temperature -55 +125




P
Max. Case Temperature Operating Temperature curve range -40 100
Lead Temperature 1.5mm from case for 10 seconds 300




P
Cooling Free air convection

Module in every environment temperature rating, case temperature under shall not exceed the maximum case temperature level.

MECHANICAL DIMENSIONS PIN CONNECTIONS




O
Units: mm Tolerance: ± 0.2mm

Pin Single output




T
1 -Vin
2 CASE
3 CTL
4 +Vin
5 +Vo
6 +S
7 TRIM
8 -S
9 -Vo




www.gztoppower.com TEL0086-20-62162688 [email protected] page 2 of 3
TP100~200DH Series
MODEL SELECTION
TP 100 D H 24 S 05


Output voltage

S: Single output D: Dual output
Input Rated Voltage

Package type
DC-DC




R
Output rated power
Brand name




E
USING ATTENTIONS

Module will cause irreversible damage when in the state of the input reverse polarity.
Module will cause irreversible damage when in the long-term overload conditions.




W
Module will cause irreversible damage when out of the maximum input voltage range.




O
STEMPERATURE DERATING GR




P P
T O
www.gztoppower.com TEL0086-20-62162688 [email protected] page 3 of 3