CE Mark Information
for the DAS-1800 Series
Note: Products that contain the CE Mark are certified to meet European
EMC directive 89/336 EEC. If this directive is not of importance to your
application, please disregard the information in this document.


Keithley MetraByte certifies that this product has been tested and found
to be in compliance with the EMC directive and relevant harmonized
standards.

This document describes the limitation of certification, the declaration of
conformity, and the cabling instructions required for the CE Mark
configuration.


Limitation of Certification

This certification applies only to the operation of the product (with
specified cables and accessories) in the stated configuration and under the
stated operational and environmental specifications. Any modification,
misuse, or improper or inadequate maintenance of the product by the user
voids this certification.

Any deviation from the specific configuration may cause emissions or
susceptibility not within the allowed limits required by the stated
directive. It is the user's responsibility to demonstrate and maintain
compliance with the directive and standards.

Please read the next section, "Declaration of Conformity," for the specific
testing configuration for this product. Consult the Keithley Instruments
GMBH office (European importer) or Technical Support in Taunton, MA,
USA, for further information regarding the exact configuration details and
testing.



Part Number: 24642; Revision B 1
Declaration of Conformity

Application of Council Directive(s) 89/336/EEC
Standard(s) to which Conformity is EN50081-1, EN50082-1
Declared
Manufacturer's Name Keithley MetraByte
Importer's Name Keithley Instruments GMBH
Importer's Address Landsberger Str.65 D-82110 Germering, Munich
Type of Equipment Data Acquisition Plug-in Boards
Model Numbers DAS-1801ST, DAS-1802ST, DAS-1801ST-DA,
DAS-1802ST-DA, DAS-1802HR, DAS-1802HR-DA,
DAS-1801AO, or DAS-1802AO with EXP-1800, an ENCL
Series enclosure, FWA-EXP, FWA-1800U, and SDAS-2000

DAS-1801HC or DAS-1802HC with STA-1800HC and
CAB-1800/S
Year of Manufacture 1995


I, the undersigned, hereby declare that the equipment specified above conforms
to the above Directive(s) and Standard(s).
Place: Taunton, MA USA
___________________________________
(Signature)

Date: 01 January 1996 Mark Urban
(Name)

Quality Assurance Manager
(Position)




2 January 1996
Cabling Instructions for the CE Mark Configuration

When using an EXP-1800 as part of the CE Mark configuration, you must
use an ENCL Series enclosure. The ENCL-1 supports one EXP-1800, the
ENCL-2 supports two EXP-1800s, and the ENCL-4 supports four
EXP-1800s.

Each version of the ENCL Series enclosure contains slotted card guides
and a rear panel that accommodates the rear connectors of each installed
EXP-1800. To install an EXP-1800 in an ENCL Series enclosure,
perform the following steps:
1. Remove the four standoffs from each EXP-1800 to be installed.
2. Insert the EXP-1800 into the slots of a pair of card guides.
3. Gently push the EXP-1800 toward the rear of the desktop enclosure
until the front-panel screws meet the tapped holes on the card guides.
4. Fasten the front-panel screws to the card guides.

An ENCL-4 containing four EXP-1800s is shown in Figure 1.




Figure 1. ENCL-4 Enclosure with Four EXP-1800s Installed




Part Number: 24642; Revision B 3
Once the EXP-1800 is installed in the ENCL Series enclosure, connect
the EXP-1800 directly to the main I/O connector of a DAS-1800ST/HR/
AO Series board through the SDAS-2000 cable, as shown in Figure 2.
Figure 2 also shows where to attach the FWA-EXP and FWA-1800U.
Refer to the DAS board and EXP-1800 user's guides for more
information.

FWA-EXP FWA-1800U


J5
J1



Note: When using an EXP-1800, remember to
EXP-1800 configure the channels of the DAS board as
single-ended inputs.
J6 J7




DAS-1800ST/HR/AO Series Board

SDAS-2000
Cable



Figure 2. Connecting the DAS-1800ST/HR/AO Series Board to an EXP-1800, FWA-EXP,
and FWA-1800U




4 January 1996
Use the CAB-1800/S cable to connect an DAS-1800HC Series board to
an STA-1800HC as shown in Figure 3. Refer to the DAS-1800HC Series
User's Guide for more information.




DAS-1800HC Series Board




CAB-1800/S
Cable




STA-1800HC




Figure 3. Connecting a DAS-1800HC Series Board to an STA-1800HC




Part Number: 24642; Revision B 5