Getting Started with TDSHT3 4. To connect the DUT, click Tests > Connect. 8. If you have run the tests successfully, the software
makes Result available automatically and displays the
You can use this side of the quick reference card to get eye diagram plot and the clock jitter plot. You can also
started with the Source Clock- -Data Tests Select All test view both the result summary of the test and the report
procedure. The other side contains a complete menu tree for configuration in the result pane.
the TDSHT3 HDMI Compliance Test Software.

NOTE. For additional procedures, refer to the
TDSHT3 Quick Start User Manual. For
complete operating instructions, refer to the
online help.
5. Make the connections as follows:

TDSHT3 HDMI Compliance Test Software enables
unprecedented efficiency by providing a comprehensive
range of tests, including Jitter Tolerance. Start the
application by using Analyze > HDMI Compliance Test 9. In the result summary pane, click Result Details to
Software(1.3) or App > HDMI Compliance Test display the results of the tests.
Software(1.3).

Source Clock- -Data Tests Select All
This option enables you to run the Eye Diagram, Duty
Cycle, Rise Time, Fall Time, and Clock Jitter
simultaneously.
You will need one supported oscilloscope, two differential
probes, one DC power supply 3.3 V, one EDID emulator,
and one HDMI EFF- -TPA- fixture.
-P
Follow these steps: 10. In the Result Details dialog box, click Result Statistics
to display statistics based on the tests.
1. On the menu bar, click Tests > Select > Source.
-data tests pane, click Select All.
2. In the clock-




6. Ensure that your signal in the oscilloscope display is
similar to the sample signal. Click View Waveform to
display a sample of the expected signal. If the displays
are not similar, go back and check your configuration
and connections. The software calculates statistics for each selected test, and
3. To change the configuration settings, click Tests > logs the statistics on a cycle- -cycle basis in a fairly large
-by-
Configure. For most tests, you can use the factory waveform. The standard statistics are for the Maximum,
default configuration. However, you can change the Minimum, Mean, Standard Deviation, and Population.
values by using the virtual keyboard or the general
purpose knob on the oscilloscope front panel. You can
also restore the factory defaults or save and recall your
own configuration settings.




7. Click Run Test to perform the test. The TDSHT3
HDMI Compliance Test Software sets up the
oscilloscope and the test runs displaying a progress
indicator.




For up-to-date information on Tektronix oscilloscope Recommended Accessories
solutions for HDMI Compliance Test Software, access the
www.tektronix.com Web page. Oscilloscopes
H 16 M Record Length/Ch: Opt. 4 M or more (Eye
TDSHT3 Ordering Information Diagram and Jitter tests)
This software supports the TDS6000B, TDS6000C, HDMI Pattern Sources
TDS7254/TDS7254B, TDS7404/TDS7404B, CSA7404/
CSA7404B, TDS7704B, and DPO70000 series of H Jitter Generation: AWG7102/AWG710/AWG710B/
oscilloscopes. Refer to the Optional Applications Software AFG3000 (minimum two channel AFG) for Sink tests
on Windows-Based Oscilloscopes Installation Manual for a H Test Pattern Generation: DTG5274/DTG5334,
list of specific models. The applications CD includes a PDF DTGM30 (three required), and DTGM32 (one required
file of the online help. for AFG3000/AWG710/AWG710B) for sink tests
To order along with oscilloscope: TDR Tests
H Opt. HT3 - HDMI Compliance Test Software
- H Oscilloscope: TDS8200B/DSA8200 with 80E03 and
80E04 modules
To order an upgrade for an existing oscilloscope:
Probes
H TDS6000B - Order TDS6BUP - Opt. HT3
- -
H Differential Probes: P7313SMA for both single-ended
H TDS7000/B - Order TDS7UP/7BUP - Opt. HT3
- -
and differential measurements. P7350SMA can be used
H CSA7000/B - Order TDS7UP/7BUP - Opt. HT3
- - for differential tests of limited resolutions.
H DPO70000 - Order DPO7UP - Opt. HT3
- - H Active Probes: P7240 (two probes) for single ended
To order an upgrade from HDMI 1.2a to HDMI 1.3a measurements using old fixtures.
compliance test software: H Probe Positioner: PPM100 Flexible Arm Probe Posi-
TDSHT3
tioner. HDMI Compliance Test Software
H TDS6000B - Order TDS6BUP - Opt. HT23
- -
Test Fixtures Reference Source Test
H TDS7000/B - Order TDS7UP/7BUP - Opt. HT23
- -
H CSA7000/B - Order TDS7UP/7BUP - Opt. HT23
- - H Plug type: EFF- -HDMI- -TPA- available from Efficere
-P,
Technologies
H DPO70000 - Order DPO7UP - Opt. HT23
- -
H Receptacle type: EFF- -HDMI- -TPA- available from
-R,
Efficere Technologies
NOTE. You will be provided with two
TDSHT3 applications, one supporting H Receptacle type: HDMI TPA- adapter set -
-R -
CTS 1.2a specification, displayed as 013--A012- (can be used for limited resolution)
-50
TDSHT3, and the other for CTS 1.3a H Plug type: HDMI TPA- adapter set - 013-
-P - -A013- -50
specification, displayed as TDSHT3v1.3. Both (can be used for limited resolution)
applications can be loaded onto the
oscilloscope, but you can run only one
application at a time.




www.tektronix.com
*P071195902*
071-1959-02
TDSHT3 Menu Tree
Recall Default
Recall
Save
File Recall Recent Position Eye Mask in Center
Preferences Acquisition Alert Message
Minimize
Exit

Eye Diagram
Source Duty Cycle
Select Sink Rise Time
Cable Fall Time
Clock Jitter
Inter-- Pair Skew (Data-- Data Tests)
Source Intra-- Pair Skew
Low Amplitude +
Low Amplitude