Text preview for : Samsung+LED+Mon+SA300.pdf part of Samsung Samsung+LED+Mon+SA300 Samsung Monitor Monitor WDM1 chassis Samsung+LED+Mon+SA300.pdf



Back to : Samsung+LED+Mon+SA300.pdf | Home










































































!
!
"#$ !
$%&'( !)*

+
+ ,-./
012345
012345

01

6789
6789
6789
:;<=>

?@ABC> DE
?@ABC> FG
67AHIJKLM
NO
PQR2ST,
PQR2ST,
P
ST,
UVR
UVR
UVR

WXYUZW
YU[\







































































]^_`Xabcdea _`Xabcd
:fghijkl\mnoj(pq2rpst xhea
u(vw ypz{





1. Precautions

1. Precautions
1-1. Safety Precautions
Follow these safety, servicing and ESD precautions to prevent damage and to protect against potential hazards such as
electrical shock.

1-1-1. Warnings
1. For continued safety, do not attempt to modify the circuit board.
2. Disconnect the AC power and DC power jack before servicing.

1-1-2. Servicing the LCD Monitor
1. When servicing the LCD Monitor, Disconnect the AC line cord from the AC outlet.
2. It is essential that service technicians have an accurate voltage meter available at all times. Check the calibration of
this meter periodically.

1-1-3. Fire and Shock Hazard
Before returning the monitor to the user, perform the following safety checks:
1. Inspect each lead dress to make certain that the leads are not pinched or that hardware is not lodged between the
chassis and other metal parts in the monitor.
2. Inspect all protective devices such as nonmetallic control knobs, insulating materials, cabinet backs, adjustment and
compartment covers or shields, isolation resistorcapacitor networks, mechanical insulators, etc.
3. Leakage Current Hot Check (Figure 1-1):
WARNING : Do not use an isolation transformer during this test.
Use a leakage current tester or a metering system that complies with American National Standards Institute (ANSI
C101.1, Leakage Current for Appliances), and Underwriters Laboratories (UL Publication UL1410, 59.7).
(READING SHOULD)
NOT BE ABOVE 0.5mA




LEAKAGE
DEVICE
CURRENT
UNDER
TESTER
TEST

TEST ALL
EXPOSED METAL
SURFACES


2-WIRE CORD




*ALSO TEST WITH
PLUG REVERSED
(USING AC ADAPTER
PLUG AS REQUIRED)
EARTH
GROUND
Figure 1-1. Leakage Current Test Circuit
4. With the unit completely reassembled, plug the AC line cord directly into a 120V AC outlet. With the unit's AC switch
first in the ON position and then OFF, measure the current between a known earth ground (metal water pipe, conduit,
etc.) and all exposed metal parts, including: metal cabinets, screwheads and control shafts.
The current measured should not exceed 0.5 milliamp.
Reverse the power-plug prongs in the AC outlet and repeat the test.

1-1-4. Product Safety Notices
Some electrical and mechanical parts have special safetyrelated characteristics which are often not evident from visual
inspection. The protection they give may not be obtained by replacing them with components rated for higher voltage,
wattage, etc. Parts that have special safety characteristics are identified by on schematics and parts lists. A substitute
replacement that does not have the same safety characteristics as the recommended replacement part might create
shock, fire and/or other hazards. Product safety is under review continuously and new instructions are issued whenever
appropriate.




1-1
1. Precautions

1-2. Servicing Precautions
WARNING: An electrolytic capacitor installed with the wrong polarity might explode.
Caution: Before servicing units covered by this service manual, read and follow the Safety Precautions section of
this manual.
Note: If unforeseen circumstances create conflict between the following servicing precautions and any of the
safety precautions, always follow the safety precautions.

1-2-1 General Servicing Precautions
1. Always unplug the unit's AC power cord from the AC power source and disconnect the DC Power Jack before
attempting to:
(a) remove or reinstall any component or assembly, (b) disconnect PCB plugs or connectors, (c) connect a test
component in parallel with an electrolytic capacitor.
2. Some components are raised above the printed circuit board for safety. An insulation tube or tape is sometimes
used. The internal wiring is sometimes clamped to prevent contact with thermally hot components. Reinstall all such
elements to their original position.
3. After servicing, always check that the screws, components and wiring have been correctly reinstalled. Make sure that
the area around the serviced part has not been damaged.
4. Check the insulation between the blades of the AC plug and accessible conductive parts (examples: metal panels,
input terminals and earphone jacks).
5. Insulation Checking Procedure: Disconnect the power cord from the AC source and turn the power switch ON.
Connect an insulation resistance meter (500 V) to theblades of the AC plug.
The insulation resistance between each blade of the AC plug and accessible conductive parts (see above) should be
greater than 1 megohm.
6. Always connect a test instrument's ground lead to the instrument chassis ground before connecting the positive lead;
always remove the instrument's ground lead last.

1-3. Static Electricity Precautions
Some semiconductor (solid state) devices can be easily damaged by static electricity. Such components are commonly
called Electrostatically Sensitive Devices (ESD). Examples of typical ESD are integrated circuits and some field-effect
transistors. The following techniques will reduce the incidence of component damage caused by static electricity.
1. Immediately before handling any semiconductor components or assemblies, drain the electrostatic charge from your
body by touching a known earth ground. Alternatively, wear a discharging wrist-strap device. To avoid a shock hazard,
be sure to remove the wrist strap before applying power to the monitor.
2. After removing an ESD-equipped assembly, place it on a conductive surface such as aluminum foil to prevent
accumulation of an electrostatic charge.
3. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ESDs.
4. Use only a grounded-tip soldering iron to solder or desolder ESDs.
5. Use only an anti-static solder removal device. Some solder removal devices not classified as "anti-static" can generate
electrical charges sufficient to damage ESDs.
6. Do not remove a replacement ESD from its protective package until you are ready to install it. Most replacement ESDs
are packaged with leads that are electrically shorted together by conductive foam, aluminum foil or other conductive
materials.
7. Immediately before removing the protective material from the leads of a replacement ESD, touch the protective
material to the chassis or circuit assembly into which the device will be installed.
Caution: Be sure no power is applied to the chassis or circuit and observe all other safety precautions.
8. Minimize body motions when handling unpackaged replacement ESDs. Motions such as brushing clothes together,
or lifting your foot from a carpeted floor can generate enough static electricity to damage an ESD.




1-2
1. Precautions

1-4. Installation Precautions
1. For safety reasons, more than two people are required for carrying the product.
2. Keep the power cord away from any heat emitting devices, as a melted covering may cause fire or electric shock.
3. Do not place the product in areas with poor ventilation such as a bookshelf or closet. The increased internal
temperature may cause fire.
4. Bend the external antenna cable when connecting it to the product. This is a measure to protect it from being exposed
to moisture. Otherwise, it may cause a fire or electric shock.
5. Make sure to turn the power off and unplug the power cord from the outlet before repositioning the product. Also check
the antenna cable or the external connectors if they are fully unplugged. Damage to the cord may cause fire or electric
shock.
6. Keep the antenna far away from any high-voltage cables and install it firmly. Contact with the highvoltage cable or the
antenna falling over may cause fire or electric shock.
7. When installing the product, leave enough space (10cm) between the product and the wall for ventilation purposes.
A rise in temperature within the product may cause fire.




1-3
1. Precautions

Memo




1-4
2. Product specifications

2. Product specifications
2-1. Feature & Specifications
S19A300B / S19A300N

Feature

Panel Specifications: 250 cd/m2, 5 ms, CR 1000:1, 170/160 (CR>10)
DPMS : <0.3W
Off-Timer function for reducing standby power usages
DVI with HDCP (S19A300N: Analog only)
Picture;a screen size desire
Supported Magic Bright3/Magic Eco/Magic Angle/Magic Return off timer/Image Size/Color Effect/Key Repeat Time

Specifications

Item Description
Model S19A300B S19A300N
LCD Panel TFT-LCD panel, RGB vertical stripe, normally white transmissive
18.5" Wide viewable
0.300(H) x 0.300(V)mm pixel pitch
Scanning Frequency Horizontal : 30kHz ~ 81kHz (Automatic)
Vertical: 56Hz ~ 75Hz
Display Colors 16.7 Million colors
Maximum resolution Horizontal: 1366 Pixels
Vertical: 768 Pixels
Input Signal Analog / DVI digital with HDCP Analog
Input Sync Signal Seperate H/V sync, Composite H/V, Sync-on-Green
Level: TTL level
Maximum Pixel Clock rate 89Mhz
Active Display
409.8 (H) x 230.4(V)
(Horizontal/Vertical)
AC power voltage &
AC 100V~130V, 60Hz & AC, 200V~240V 50Hz
Frequency
Power Consumption MAX 21W / Typical 19W
Dimensions Set 445 X 273 X 53 mm (Without Stand)
(W x H x D) 445 X 348 X 177 mm (With Stand)
Weight Set
2.3 kg
(After installation Stand)
Environmental Considerations Operating Temperature: 10