File name Pa99-04.pdf For internal use only PHILIPS ISSUE PA99.04 (99-10-13) Published by: Service Department Portable Audio LINE OF BUSINESS PORTABLE AUDIO SERVICE NEWSLETTER 04.01 TYPENUMBER(S): AJ3290 INFORMATION : The Clock set button can get stuck inside when too much force is applied on the button. A rib will be added on the top cabinet as stopper. REMARKS : Modification will be implemented in production from week 9948 onwards. 04.02 TYPENUMBER(S): AJ3940 INFORMATION : Additional information to Service Newsletter PA99.02.04. The transformer hum can be further reduced by adding 2 pieces of sponge (about 20x15x2mm) between transformer and shield plate. REMARKS : Modification has been implemented in production from week 9902 onwards. 04.03 TYPENUMBER(S): AZ1010 INFORMATION : On special request the following parts were added to the service partslist: pos code number article description | ||