datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Philips p16 p20

Philips p16 p20 free download

Computer monitors - CRT, TFT, LCD, touch screen, plasma display - service manuals and repair information

File information:
File name:p16_p20.pdf
Size:121 kB
Extension:pdf
Mfg:Philips
Model:p16 p20 🔎
Original:p16 p20 🔎
Descr: Philips Monitor CD 2001 Monitor CD 2001 E-MANUALS Philips crt 109b2 pdf p16_p20.pdf
Group:Electronics > Computer equipment > Monitors
Uploaded:13-05-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name p16_p20.pdf

16 109B2 GS3 CM25 Electrical Instructions Go to cover page 0. General - Connect a "high-voltage voltmeter" between the high- voltage connection of the picture tube and earth. When carry-out the electrical settings in many cases a video - Turn on the power. signal must be applied to the monitor. A computer with : - Set the EHT trimming potentiometer R3587 so that the "high- voltage voltmeter" reads 26.5 KV +/- 0.5 KV . - ATI GPT-1600 (4822 397 10065), Mach 64 (up to 107kHz) - Turn off the power. are used as the video signal source. The signal patterns - Remove the "high-voltage voltmeter" from the picture tube. are selected from the "service test software" package, see - Turn on the power again. user guide 4822 727 21046 (GPT-1600). 3. Monitor the following auxiliary voltages. 0.1 This monitor has 35 factory-preset modes as below: SOURCE ACROSS C2152 + 190.0V +/- 1.0VDC. 640 x 350 37.9 kHz/85 Hz 1152 x 870 68.7 kHz/75 Hz SOURCE ACROSS C2154 + 79.0V +/- 1.0VDC. 640 x 400 31.5 kHz/70 Hz 1152 x 900 71.8 kHz/76 Hz SOURCE ACROSS C2156 - 6.3V +/- 0.3VDC. 640 x 480 31.5 kHz/60 Hz 1280 x 960 60.0 kHz/60 Hz SOURCE ACROSS C2160 + 13.5V +/- 0.5VDC. 640 x 480 37.9 kHz/72 Hz 1280 x 960 85.9 kHz/85 Hz SOURCE ACROSS C2157 - 13.5V +/- 0.5VDC. 640 x 480 37.5 kHz/75 Hz 1280 x 1024 63.9 kHz/60Hz 640 x 480 43.3 kHz/85 Hz 1280 x 1024 79.9 kHz/75 Hz 640 x 480 50.6 kHz/100 Hz 1280 x 1024 91.1 kHz/85 Hz 4. General conditions for alignment 720 x 400 31.5 kHz/70 Hz 1600 x 1200 75.0 kHz/60 Hz 720 x 400 37.9 kHz/85 Hz 1600 x 1200 81.3 kHz/65 Hz 4.1 During all alignments, supply a distortion free AC mains 800 x 600 37.9 kHz/60 Hz 1600 x 1200 87.5 kHz/70 Hz voltage to set via an isolating transformer with low internal 800 x 600 48.1 kHz/72 Hz 1600 x 1200 93.8 kHz/75 Hz impedance. 800 x 600 46.9 kHz/75 Hz 1792 x 1344 83.6 kHz/60 Hz 4.2 Align in pre-warmed condition, at least 30 minutes warm- 800 x 600 53.7 kHz/85 Hz 1856 x 1392 86.3 kHz/60 Hz up with nominal picture brightness. 800 x 600 63.9 kHz/100 Hz 1920 x 1440 90.0 kHz/60 Hz 4.3 Purity, geometry and subsequent alignments should be 832 x 624 49.7 kHz/75 Hz 1024 x 768 48.4 kHz/60 Hz

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Philips p16 p17 - Philips p29 v - Philips Philips 3104 313 6009.5 [SCH] - Philips Philips 3104 313 6082.2 [SCH] - Philips Philips 3104 328 27821 [SCH] - Philips Philips 3104 313 6065.1 [SCH] - Philips Philips 3104 313 6128.2 [SCH] -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Sony WM-D6C

script execution: 0.04 s