datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Sharp UX108-118S

Sharp UX108-118S free download

Various electronics service manuals

File information:
File name:SHARP UX108-118S.part5.rar
[preview UX108-118S]
Size:244 kB
Extension:
Mfg:Sharp
Model:UX108-118S 🔎 UX108118S
Original:UX108-118S 🔎
Descr:SHARP UX108-118S FAX Machine.part5
Group:Electronics > Other
Uploaded:09-03-2004
User:plamensl
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:3
File name Ux108S-DESCR.pdf

UX-108H UX-178H [3] Circuit description of TEL/LIU PWB (1) TEL/LIU block operational description 1) Block diagram TEL/LIU PWB CML CONTROL PWB TEL LINE SURGE PROTECTION BLOCK LINE FILTER BLOCK ON-HOOK BLOCK POLARITY GUARD BLOCK DIAL PULSE GENERATION BLOCK TXOUT SPEECH CIRCUIT BLOCK RXIN 0 1 SIGTX EXT. DIAL CONTROL BLOCK CI DETECTOR MODEM (R96DFXL-CID) SIGRX RX MUTE HANDSET VOL A VOL B VOL C BZCONT 0 1 SPEAKER GAIN-C RX MUTE XFC3 BZCONT SP MUTE CML DP ON CI RHS +5V +24VA DG DP ON CI RHS Fig. 5 2) Circuit description The TEL/LIU PWB is composed of the following 9 blocks. 1. Surge protection circuit 2. Line filter block 3. Dial pulse generation circuit 4. On-hook circuit 5. Matching transformer 6. Hybrid circuit 7. Signal selection 8. Cl detection circuit 9. Power supply and bias circuit 3) Block description 1. Surge Protection circuit This circuit protects the circuit from the surge voltage occurring on the telephone line. · The AR1, AR2 protects the circuit from the 425V or higher line surge voltages. 5­8 UX-108H UX-178H 2. Line filter block The block is comprises of coil L2. 3. Dial pulse generation circuit The pulse dial generation circuit comprises of transistor Q1, the photocoupler PC2, PC8, and zener diode ZD9. Dial pulse supplied from CPU are amplified by transistor Q1 through a photo-coupler PC4 to the telephone line. 4. On-hook circuit This circuit comprises of CML relay and switch SW2, and CML and SW3 are for connection of the telephone line. 5. Matching transformer The matching transformer performs electrical insulation from the telephone line and impedance matching for transmitting the TEL/FAX signal. 6. Hybrid circuit The hybrid circuit performs 2-wire-to-4-wire conversion using the IC101 of operational amplifier, transmits the voice transmission signal to the line, and feeds back the voice signal to the voice reception circuit as the side tone. VOL A VOL B VOL C (The circuit is located in the control PWB.) 7. Signal selection The following signals are used to control the transmission line of TEL/ FAX signal. For details, refer to the signal selector matrix table. [Control signals from output port] Signal Name CML Description Line connecting relay and DP generating relay (The circuit is located H: Line make in the TEL/LIU PWB.) L: Line break SP MUTE (The circuit is located in the TEL/LIU PWB.) Speaker tone mute control signal H: Muting (Power down mode) L: Muting cancel (Normal operation) Handset reception mute control signal H: Muting L: Muting cancel DP generating relay H: DP make L: DP break Speaker volume control signal VRSEL1 VRSEL2 matrix VOL A VOL B VOL C RING SP.REC. /DTMF BUZZER RX MUTE DP ON H L L L L H L L L L H L High High -- -- Middle -- Middle -- -- Low Low Fixed TXCONT (The circuit is located in the control PWB.) TXOUT mute signal H: Signal sending, when transmitting L: During reception, transmission mute, (during standby) Reception gain switching signal L: When connected to line, 1: 1 g
File name Ux108S-DIAGNOSTIC.pdf

UX-108H UX-178H [2] Diagnostics and service soft switch 1. Operating procedure (1) Entering the diagnostic mode Press FUNC 9 8 # 7 , and the following display will appear. ROM Ver. FWV0 (FXN0 ) After 2 sec: DIAG MODE FWV0 (UX-108H) FXN0 (UX-178H) Then press the START key. Select the desired item with the (Diag·specifications) key or the # key or select with the rapid key. Enter the mode with the START key. FUNC 9 8 7 FWV0 FXN0 DIAG MODE START Soft switch mode ROM & RAM check Aging mode Panel check mode Check pattern mode START START START START START 1 2 3 4 5 10 9 8 7 6 START START START Auto feeder mode All black mode Shading mode START Memory clear mode START Signal send mode If the diag mode cannot be set, repeat the diag mode operation, performing the following operation. After the power is turned on and "WAIT A MOMENT" is indicated, press the STOP key. STOP KEY "Power ON" + + START KEY In relation with the process response (request from Production Engineering) "WAIT A MOMENT" clock indication may appear depending on STOP key timing. If the STOP key is held down, "MEMORY CLEAR?" appears. Memory clear (Work + Backup) 2. Diagnostic items ITEM No. 1 2 3 4 5 6 7 8 9 10 DIRECT key 1 2 3 4 5 6 7 8 9 10 Contents SOFT SWITCH MODE ROM & RAM CHECK AGING MODE PANEL CHECK MODE Function Soft switches are displayed and changed. List can be output. ROM is sum-checked, and RAM is matched. Result list is output. 10 sheets of check patterns are output every 5 minutes per sheet. Panel keys are tested. Result list is output. CHECK PATTERN MODE Check pattern is output. SIGNAL SEND MODE Various signals of FAX communication are output. MEMORY CLEAR MODE Back-up memory is cleared, and is set at delivery. SHADING MODE ALL BLACK MODE AUTO FEEDER MODE Shading compensation is performed in this mode. To check the print head, whole dots are printed over the interval of 2 m. Insertion and discharge of document are tested. 2­2 UX-108H UX-178H 3. Diagnostic items description 3. 1. Soft switch mode Used to change the soft switch settings. The soft switch which is stored internally is set by using the keys. The available soft switches are SW-A1 to SW-L2. The content of soft switches is shown in page 2-5 to 2-15. The contents are set to factory default settings. 3. 6. Signal send mode The mode is used to send various signals to the circuit during FAX communication. Every push of START key sends a signal in the following sequence. Moreover, the signal sound is also output to the speaker when the line monitor of the soft switch is on. [1] No signal (CML signal turned on) [2] 9600bps [3] 7200bps [4] 4800bps [5] 2400bps [6] 300bps (FLAG) [7] 2100Hz (CED) [8] 1100Hz (CNG) [9] END 3. 2. ROM & RAM check ROM executes the sum check, and RAM executes the matching test. The result will be notified with the number of short sounds of the buzzer as well as by printing the ROM & RAM check list. Number of short sounds of buzzer 0 No error 1 ROM error 2 RAM
File name Ux108S-GENERAL.pdf

UX-108H UX-178H CHAPTER 1. GENERAL DESCRIPTION [1] Specifications Automatic dialing: Fax paper: Rapid Key Dialing: 10 numbers Speed Dialing: 20 numbers Initial starter roll (included with fax machine): 10 m roll Recommended replacement roll: FO-40PR6(R) 50 m roll Automatic document feeder: 10 sheets max. Paper cutting method: Modem speed: Transmission time* : Display: Reception modes: Resolution: UX-108: Tear off by hand UX-178: Automatic cutter 9600 bps with automatic fallback to 7200, 4800, or 2400 bps Approx. 15 seconds 16-digit LCD display FAX, TEL, TEL/FAX, A.M. Horizontal: 8 dots/mm Vertical: Standard: 3.85 lines/mm Fine/Halftone: 7.7 lines/mm Super fine (transmission only) : 15.4 lines/mm Thermal recording 64 levels/16 levels Public switched telephone network/PBX ITU-T (CCITT) G3 mode Half-duplex, desktop transceiver Modified Huffman and Sharp special mode (MR/MH/UNIQUE) Sheet-feeder CIS (Contact Image Sensor) 210 mm max. Automatic feeding: Width 148 to 216 mm Length 140 to 297 mm Manual feeding: Width 148 to 216 mm Length 140 to 600 mm Dimensions: Effective scanning width: Contrast control: Copy function: Telephone function: 210 mm max. Automatic/Dark selectable Standard Standard (cannot be used for incoming/outgoing calls if power fails) 230 V AC, 50 Hz 5 to 35°C Maximum: 85 % Stand-by: 5.5 W Maximum: 120 W Width: 308 mm Depth: 256 mm Height: 138 mm Weight: * UX-108: Approx. 2.5 kg UX-178: Approx. 2.6 kg Power requirements: Operating environment: Humidity: Power consumption: Based on ITU-T (CCITT) Test Chart #1 at standard resolution in Sharp special mode, excluding time for protocol signals (i.e., ITU-T phase C time only). Recording system: Halftone (grayscale): Applicable telephone line: Compatibility: Configuration: Compression scheme: Scanning method: Effective recording width: Input document size: As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification changes for procduct improvement without prior notice. The performance specifications figures indicated are nominal values of production units. There may be some deviation from these values in individual units. 1­1



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Sharp FO-90RA - Sharp R-350A - Sharp R-870B - Sharp LC-20C2E - Sharp LC-15C2E - Sharp LC-13C2E - Sharp R-217E -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Anton 2000XT

script execution: 0.02 s