datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent 5991-3578EN HBT Prescaler Evaluation Board - Technical Overview c20140718 [2]

Agilent 5991-3578EN HBT Prescaler Evaluation Board - Technical Overview c20140718 [2] free download

Various electronics service manuals

File information:
File name:5991-3578EN HBT Prescaler Evaluation Board - Technical Overview c20140718 [2].pdf
[preview 5991-3578EN HBT Prescaler Evaluation Board - Technical Overview c20140718 [2]]
Size:998 kB
Extension:pdf
Mfg:Agilent
Model:5991-3578EN HBT Prescaler Evaluation Board - Technical Overview c20140718 [2] 🔎
Original:5991-3578EN HBT Prescaler Evaluation Board - Technical Overview c20140718 [2] 🔎
Descr: Agilent 5991-3578EN HBT Prescaler Evaluation Board - Technical Overview c20140718 [2].pdf
Group:Electronics > Other
Uploaded:25-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 5991-3578EN HBT Prescaler Evaluation Board - Technical Overview c20140718 [2].pdf

Keysight Technologies HBT Prescaler Evaluation Board Technical Overview Description A connectorized evaluation PC board is available for Keysight Technologies, Inc. HBT prescalers. Table 1 lists the six SOIC8 packaged prescalers and their main features. See individual data sheets for additional features and specifications. The evaluation PC board allows single bias operation from either a positive or negative supply. See Table 2. The PC board layout permits single ended or differential operation from ~200 MHz to 12/16 GHz input signal bandwidth. All RF ports are AC coupled, allowing direct connection to test equipment or additional circuitry, independent of selected bias polarity. For single ended operation the unused RF input port should be unterminated, and the unused RF output port should be terminated in 50 . For additional information, contact WPTC Marketing. Table 1. Available Evaluation Boards Table 2. Single Bias Operation Product No Divide modulus fmax (GHz) Icc or Iee (mA) Vcc Vee TC209P 2 12 35 to 40 Positive supply +4.5 V to +6.5 V GND TC207P 4 12 35 to 40 Negative supply GND

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Marantz CD-84

script execution: 0.07 s