Now downloading free:Agilent 5990-9325EN ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note c20140613 [9]


Download Agilent 5990-9325EN ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note c20140613 [9] docs - Various electronics service manuals


File information:
File name:5990-9325EN ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note c20140613 [9].pdf
[preview 5990-9325EN ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note c20140613 [9]]
Size:2976 kB
Extension:pdf
MD5:78fa73676cc9b0bce54ae758e2fcef24
Mfg:Agilent
Model:5990-9325EN ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note c20140613 [9] 🔎
Original:5990-9325EN ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note c20140613 [9] 🔎
Descr: Agilent 5990-9325EN ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note c20140613 [9].pdf
Group:Electronics > Other >
Uploaded:26-08-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File nameText
5990-9325EN ARINC 429 Eye-diagram and Pulse-shape Mask Testing - Application Note c20140613 [9].pdfKeysight Technologies ARINC 429 Eye-diagram and Pulse-shape Mask Testing Application Note Introduction Eye-diagram mask testing is used in a broad range of today's serial bus applications. An eye-diagram is basically an overlay of all bits captured by the scope to show when bits are valid and not valid. This provides a composite picture of the overall quality of a system's physical layer characteristics, which includes amplitude variations possibly due to transmission line affects, reflections, system noise, over-shoot, ringing, signal edge timing, and jitter. Eye-diagram and pulse-shape pass/fail mask testing can be performed on differential ARINC 429 signals using a Keysight Technologies, Inc. 3000, 4000 or 6000 X-Series oscilloscope licensed with the DSOX3AERO/DSOX4AERO/DSOX6AERO triggering and decode option (MIL-STD 1553 & ARINC 429), along with the DSOX3MASK/DSOX4MASK/DSOX6MASK mask test option

>> View document online <<



>> Download document << eServiceInfo Context Help

Did You find this Service Manual useful? Share it:



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent HP 86100 Series Ref - Agilent N9342C 7 GHz Handheld Spectrum Analyzer - Quick Fact Sheet 5990-5949EN c20140612 [2] - Agilent 5991-3195EN Low PIM Coaxial Switches - Data Sheet c20140919 [21] - Agilent HP N 250-2 Application Note - Agilent 16520-90908 16520A-21A Programming Reference Sept88 - Agilent HP N6701A USER - Agilent M9188_ProgrammingGuide M9188A PXI Dynamic D A Converter programming guide [96] -



 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Сдружение на радиотехниците в България Радиотехник 1945, 1946

script execution: 0.05 s