datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Wincap [snap-in] SN105 Series

Wincap [snap-in] SN105 Series free download

Electronic components, integrated circuits, semiconductor - datasheets and schematics

File information:
File name:Wincap [snap-in] SN105 Series.pdf
[preview [snap-in] SN105 Series]
Size:625 kB
Extension:pdf
Mfg:Wincap
Model:[snap-in] SN105 Series 🔎
Original:[snap-in] SN105 Series 🔎
Descr: . Electronic Components Datasheets Passive components capacitors Wincap Wincap [snap-in] SN105 Series.pdf
Group:Electronics > Components > Capacitors
Uploaded:02-07-2021
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name Wincap [snap-in] SN105 Series.pdf

SN 105 105oC Snap-In Terminal Type Specifications Electrical Characteristics Item SN 105 Life 2000 Hrs at 105oC 6.3V to 250V 350V to 450V Operating Temp. Range -40oC to +105oC -25oC to +105oC Capacitance Tolerance 20% (M) (at 20oC, 120Hz) I = 0.02CV or 3000 A whichever is smaller Leakage Current (After 5 minutes application of rated DC working voltage at 20 oC) ( A Max. at 20oC) I=Leakage Current ( A) C=Rated Capacitance ( F) V=Rated Voltage (V) Rated Voltage 6.3 10 16 25 35 50 63 80 Tan (Max.) 0.60 0.50 0.40 0.30 0.25 0.20 0.15 0.15 Dissipation Factor (tan , at 20oC, 120Hz) Rated Voltage 100 160 180-250 350-400 450 Tan (Max.) 0.15 0.10 0.10 0.15 0.25 Rated Voltage 6.3-10 160-250 350-450 Low Temperature Stability Impedance Z(-25oC) / Z(+20oC) 4 3 8 (at 120Hz) Ratio Z(-40oC) / Z(+20oC) 12 9 - Life Test 1. Load Life Capacitance Change within 20% of the initial value (after applying rated Dissipation Factor not more than 200% of specified value voltage at 105oC 2000 Leakage Current not more than the specified value hours) For shelf life leakage current measurements, the rated voltage shall be applied to the 2. Shelf Life capacitors for a minimum of 30 minutes for at least 24 hours and not more than 48 hours (no voltage applied at before the measurements. 105oC 1000 hours) Frequency (Hz) 60 120 500 1K 10K Ripple Current Multiplier of 6.3 to 100 0.90 1.00 1.05 1.10 1.15 Coefficient Frequency Coefficient 160 to 250 0.80 1.00 1.10 1.14 1.18 (WV) 350 to 450 0.80 1.00 1.05 1.10

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Wincap Wincap Series Table - Wincap [radial thru-hole] 105S5 Series - Wincap [radial thru-hole] 105HR Series - Wincap [non-polar radial] R85NP Series - Wincap [non-polar radial] 85NPX Series - Wincap [non-polar radial] 85NPS Series - Wincap [radial thru-hole] R85HV Series -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : AIWA NSX-303

script execution: 0.01 s